Andy Plumbs
Andy Plumbs
  • 40
  • 136 522
Plumbing truck tour
Hey guys, check out my service plumbing truck! It's a 2023 Ford E350 with the Rockport box. I say "stuff like that" A LOT in this video so my apologies for that! Let me know if you have any suggestions feel free to let me know. Thanks for watching!
Here are my socials
Facebook: andy.plumbs
Instagram: andy_plumbs
TikTok: www.tiktok.com/andy_plumbs
If you have questions please feel free to email me at: andyplumbs123@gmail.com
DISCLAIMER: This video is for entertainment purposes only.
Here are some of my favorite tools and EDC items:
Fenix PD35 Flashlight - amzn.to/3HheBlF
Milwuakee Fastback Knife - amzn.to/48yg2YS
Wurkkos Rechargable Headlamp - amzn.to/3SjTJRj
Leatherman Surge - amzn.to/3RW7xQo
Veto ProPac open tool bag - amzn.to/3tTDktk
Knipex Pliers Wrench - amzn.to/3O0MP0C
Knipex Cobra Pliers - amzn.to/3vAazT7
Klein 11 in 1 Screwdriver - amzn.to/41TKhqZ
Bondhus Allen Wrench Set - amzn.to/421o9uS
Ridgid Plastic Tubing Cutter - amzn.to/3HnIzo0
Ridgid Faucet Wrench - amzn.to/47zKi4g
Savage Lightning Level - amzn.to/3HhDxJP
Reed Pipe Deburring Tool - amzn.to/4aSsxjN
Ridgid Angle Stop Wrench - amzn.to/4aSsBQz
Milwaukee Tape Measure - amzn.to/47zYTNn
Zip Tie Organizer - amzn.to/4aRHceV
Knipex Side Cutters - amzn.to/3vGTZRb
Ridgid PEX Cutter - amzn.to/3HiJZAj
Moen Cartridge Puller - amzn.to/3Hf1MZg
If ya wanna send something my way send it here:
Andy Plumbs
108 N. Maple Rd #274
Saline, MI 48176
Переглядів: 330

Відео

Leonard mixing valve repair
Переглядів 8057 місяців тому
In this video I am replacing the check stops in a Leonard 2" domestic hot water mixing valve for an apartment building. If you have any suggestions feel free to let me know. Thanks for watching! Here are my socials Facebook: andy.plumbs Instagram: andy_plumbs TikTok: www.tiktok.com/andy_plumbs If you have questions please feel free to email me at: andyplumbs123@gmail....
Gas pipe repair
Переглядів 4559 місяців тому
In this video I'm bringing a gas line up to code by removing a saddle type fitting. If you have any questions or suggestions feel free to let me know. Thanks for watching! Here are my socials Facebook: andy.plumbs Instagram: andy_plumbs TikTok: www.tiktok.com/andy_plumbs If you have questions please feel free to email me at: andyplumbs123@gmail.com DISCLAIMER: This vi...
Woodford hose faucet repair
Переглядів 1119 місяців тому
In this video we're rebuilding a Woodford V22 vertical hot and cold hosebibb. If you have any questions or suggestions feel free to let me know. Thanks for watching! Here are my socials Facebook: andy.plumbs Instagram: andy_plumbs TikTok: www.tiktok.com/andy_plumbs If you have questions please feel free to email me at: andyplumbs123@gmail.com DISCLAIMER: This video is...
Easy Shellback pump replacement
Переглядів 72811 місяців тому
In this episode we're doing a simple Shellback pump swap out. These pumps are common in my area in basements when the utility sink is below the septic / sewer. If you have any suggestions feel free to let me know. Thanks for watching! Here are my socials Facebook: andy.plumbs Instagram: andy_plumbs TikTok: www.tiktok.com/andy_plumbs If you have questions please feel f...
Another water softener replacement
Переглядів 36711 місяців тому
In this episode we're replacing another water softener. This is a pretty straight forward install, nothing fancy. I'm pretty sure the existing softener was piped backwards. The customer said it had been installed that way for about 7 years. If you have any suggestions feel free to let me know. Thanks for watching! Here are my socials Facebook: andy.plumbs Instagram: a...
Sump pump replacement
Переглядів 3,4 тис.11 місяців тому
In this video you'll catch me replacing a Zoeller M63 sump pump along with a new quiet check valve. If you have any suggestions feel free to let me know. Thanks for watching! Here are my socials Facebook: andy.plumbs Instagram: andy_plumbs TikTok: www.tiktok.com/andy_plumbs If you have questions please feel free to email me at: andyplumbs123@gmail.com DISCLAIMER: This...
Water softener replacement
Переглядів 76911 місяців тому
In this video we are upgrading this customer with a new high efficiency water softener as well as a new natural gas water heater. Unfortunately I didn't get much footage of the water heater replacement as I had a helper with me that did most of the work. Let me know what you think in the comments and thanks for watching! Here are my socials Facebook: andy.plumbs Instagram: instagra...
Well tank replacement
Переглядів 1,1 тис.Рік тому
Well tank replacement
Leaking water meter
Переглядів 460Рік тому
Leaking water meter
Shower drain leaking? Let's fix it!
Переглядів 48 тис.Рік тому
Shower drain leaking? Let's fix it!
Water filtration upgrade! Sterling CS 1.5 carbon filter install
Переглядів 686Рік тому
Water filtration upgrade! Sterling CS 1.5 carbon filter install
Plumbing calls on a Wednesday
Переглядів 793Рік тому
Plumbing calls on a Wednesday
New sump pump and lid installed
Переглядів 4 тис.Рік тому
New sump pump and lid installed
Frozen water heater! Burst Pipe! Michigan Plumber - It's cold here!
Переглядів 1,7 тис.Рік тому
Frozen water heater! Burst Pipe! Michigan Plumber - It's cold here!
Replacing an old utility sink
Переглядів 1,1 тис.Рік тому
Replacing an old utility sink
How to test a RPZ backflow preventer
Переглядів 4,5 тис.Рік тому
How to test a RPZ backflow preventer
WATER LINE RAN TO FRIDGE
Переглядів 105Рік тому
WATER LINE RAN TO FRIDGE
STERLING IRON FILTER INSTALLATION
Переглядів 424Рік тому
STERLING IRON FILTER INSTALLATION
Bathroom sink drain pop up replacement
Переглядів 58Рік тому
Bathroom sink drain pop up replacement
Water softener replacement
Переглядів 55Рік тому
Water softener replacement
Tuesday service calls - water softener, toilet tank rebuild and Navien repairs.
Переглядів 84Рік тому
Tuesday service calls - water softener, toilet tank rebuild and Navien repairs.
Service calls on a Tuesday
Переглядів 56Рік тому
Service calls on a Tuesday
Disposal replacement
Переглядів 50Рік тому
Disposal replacement
Cast iron drain replacement
Переглядів 74Рік тому
Cast iron drain replacement
Noritz water heater install
Переглядів 4732 роки тому
Noritz water heater install

КОМЕНТАРІ

  • @BrianHassett-ih3jp
    @BrianHassett-ih3jp Місяць тому

    I just had an intermittant leak inside my exterior wall. Leaking through the baseboard moulding. The house sits in a slab. There are NO PIPES in this area. I sealed a bunch tiles on the roof. The leak stopped and eventually came back. I found the neighbors soaker hose blasting full stream in my concrete wall from a bad hose connection. I fixed that. I sealed the foundation. The leak stopped and came back again. Eventually, I found that the water was coming from my shower drain. The plumber's putty was wearing away. I fixed that and the leak stopped! My shower floor is four inches below the rest of the slab. The shower drain is ten feet from the exterior wall. My bedroom is another ten feet from the bathroom. The water was making a 90 degree turn when it it the bathroom wall. This is the last place you would suspect that the water was coming from. Thank God that my visiting son took a forty minute shower that last day! That's how I found the source.

    • @andy_plumbs
      @andy_plumbs Місяць тому

      @@BrianHassett-ih3jp wow that’s a fun one, glad you found it!

  • @PeterSevetz
    @PeterSevetz Місяць тому

    Great video and explanation, with awesome camera coverage! Was the leak caused by deterioration of the plumbers putty from initial install?

    • @andy_plumbs
      @andy_plumbs Місяць тому

      @@PeterSevetz yep. I see it all the time

  • @ptech88
    @ptech88 Місяць тому

    Those drains suck, i hate that stupid metal piece. Oatey used to make a fantastic shower strainer that you could tighten from the top but for some reason they stopped making them. I feel your pain on this repair.

  • @Steveoreno
    @Steveoreno Місяць тому

    NICE job for working one handed while doing the camera work!!! Thanks !!

  • @hogfanboy9443
    @hogfanboy9443 2 місяці тому

    does the condensation pipe an air path from the pit to the basement. how would you prevent the radon system from pulling air through it?

    • @andy_plumbs
      @andy_plumbs 2 місяці тому

      If I remember correctly it had a trap on it upstream of the pit

  • @justina8783
    @justina8783 2 місяці тому

    I just had to replace mine and this video was very helpful! Not too long or filled with useless info either which I appreciate. Thanks for posting this !!

  • @lawrencemeyers1212
    @lawrencemeyers1212 2 місяці тому

    Why all extra work for what light gas lol

  • @twtw2247
    @twtw2247 2 місяці тому

    You are not reading the asse 5000 book test procedures correctly bleed tc 4 then open close 1,2,3,4 when u backpressure check 2 record it as close tight and sov2 in a no flow condition .asse doesn't require second check differential.you should have moved high to 3 low to4.your reading was incorrect. I teach for 3 asse schools Michigan should have taught u better follow the book

    • @andy_plumbs
      @andy_plumbs 2 місяці тому

      Jumping test cocks is not a part of the RPZ testing procedure.

    • @twtw2247
      @twtw2247 2 місяці тому

      It's bleeding testcocks read your manual you have to eliminate air and debris.I can't believe you were taught this air is compressible water is not.your results will be wrong.

  • @wreckagevic
    @wreckagevic 3 місяці тому

    Whoever did that mess before you saved the day should be ashamed of themselves.

  • @briantownsend5124
    @briantownsend5124 3 місяці тому

    Nice install but the CS filters say they are only intended for chlorinated water (city water) and putting a “Tee” in the discharge lines is a bad idea, some of the sediment from both of them discharging will want to go up the other line and could cause problems. I’d run separate discharge lines for the softener and CS filter.

  • @Jordon.007
    @Jordon.007 3 місяці тому

    Can rpz be installed in the basement of a home when a lawn irrigation system is installed? In other words, can it be installed below the height of a lawn irrigation system?

  • @marteacalloway9001
    @marteacalloway9001 3 місяці тому

    Thank you so much for your help I received my backflow certification in August and here it is October and I finally got a chance to test my first backflow and your video was perfect. Thank you so very much.

  • @peytonhibdon7659
    @peytonhibdon7659 3 місяці тому

    Thanks for the info. Plumbing still sucks though, just sayin. 😆

  • @mbb4302
    @mbb4302 3 місяці тому

    Where can I find that little flat tool to remove drain?

    • @andy_plumbs
      @andy_plumbs 3 місяці тому

      @@mbb4302 www.premierindustrialcorp.com/product-p/d40006.htm

    • @andy_plumbs
      @andy_plumbs 3 місяці тому

      @@mbb4302 they also come with most no caulk drains

  • @MoonkaiYT
    @MoonkaiYT 3 місяці тому

    So you didn’t need to use a pair of channel locks to tighten the pvc to the pump discharge hole?

    • @andy_plumbs
      @andy_plumbs 3 місяці тому

      @@MoonkaiYT nah, I just always hand tighten them.

  • @fredisvelasquez4188
    @fredisvelasquez4188 4 місяці тому

    Great brother..

  • @smaktalker
    @smaktalker 4 місяці тому

    nice but what if you a have a slab floor with no access from bottom??

    • @andy_plumbs
      @andy_plumbs 4 місяці тому

      @@smaktalker use a Wingtite shower drain

  • @seldon_yuan
    @seldon_yuan 4 місяці тому

    Does the rubber gasket need to at the same height as the pipe? I assume the gasket should be the same height or below so it can compress down without squeezing out between the pip and the inner ring? I'm replacing my drain and am wondering how much I should adjust the height of the pipe to get the proper seal.

    • @andy_plumbs
      @andy_plumbs 4 місяці тому

      @@seldon_yuan the gasket should go slightly below the top of the pipe with the beveled side up so that the nut can compress it.

  • @michiganebayflipper9497
    @michiganebayflipper9497 4 місяці тому

    Mine swirls only seem to run. Can it just be plugged?

    • @andy_plumbs
      @andy_plumbs 4 місяці тому

      @@michiganebayflipper9497 yes likely a blockage or possibly a bad pump.

  • @abarn3917
    @abarn3917 5 місяців тому

    Your helper sure likes to talk.

  • @elkskiutah8204
    @elkskiutah8204 5 місяців тому

    Is it ok to put the water on the silicone so soon? Most say to wait 24 hours? Maybe for a test it's ok? Then tell customer to wait 24-36 hours

    • @andy_plumbs
      @andy_plumbs 5 місяців тому

      @@elkskiutah8204 most if not all silicone manufacturers have a cure time on their label. With that said, I have always run water immediately after and have never had a leak.

    • @elkskiutah8204
      @elkskiutah8204 5 місяців тому

      @@andy_plumbs good to hear... Customer wanted to use his shower 4 hours after I finished, its jsut the very edge of the silicone that's exposed and the rest can cure slowly for the full 7 day cure as specified for Dow 735

  • @jeffmartinez7724
    @jeffmartinez7724 6 місяців тому

    How long did you let the silicone dry before testing? Also do you prefer the solvent weld type drain or the one you used in the video? Great job by the way.

    • @andy_plumbs
      @andy_plumbs 6 місяців тому

      @@jeffmartinez7724 thanks! I use 100% silicone on my drains and always test almost immediately after. I’ve never had any issues doing it this way. Also, I prefer the solvent weld drains to these style as there is typically less parts to fail.

  • @gregblackley7708
    @gregblackley7708 6 місяців тому

    Good stuff !

  • @kikibellebubba1248
    @kikibellebubba1248 7 місяців тому

    Thanks for the tour

  • @mikev.1034
    @mikev.1034 7 місяців тому

    👍👍

  • @waltermendez8064
    @waltermendez8064 7 місяців тому

    nice truck

  • @alamedacustomholsters
    @alamedacustomholsters 7 місяців тому

    Flipping awesome

  • @thomasryan5681
    @thomasryan5681 7 місяців тому

    Silicone doesn't need to dry before test?

    • @andy_plumbs
      @andy_plumbs 7 місяців тому

      @@thomasryan5681 Nope. I’ve always tested right away and never had any issues.

    • @thomasryan5681
      @thomasryan5681 7 місяців тому

      @@andy_plumbs Thanks. The underside gasket must be key.

  • @mikev.1034
    @mikev.1034 7 місяців тому

    👍👍

  • @klcameron709
    @klcameron709 7 місяців тому

    Nice video. Thank you for showing the rebuild it was interesting

  • @joninnet
    @joninnet 7 місяців тому

    Reverse the hoses on your rig. The bend on the other end of your high hose will allow you to avoid that half inch water line over the test cock.

  • @majahanson311
    @majahanson311 7 місяців тому

    Is there any level of worthwhile repair to be made purely from above in this situation? I recognize that the way you did it is the right way, but if I don't want to cut away the ceiling below, is it still worth trying to just replace that rubber gasket?

    • @andy_plumbs
      @andy_plumbs 7 місяців тому

      Yes, this repair can be made from above by using a Wingtite shower drain. If you Google it you will find videos son how to install them.

  • @Invictusxiv
    @Invictusxiv 8 місяців тому

    Something I’ve noticed is nobody talks about the buffer. If you recorded it, how did you? I’m curious about the relevance of it.

    • @andy_plumbs
      @andy_plumbs 8 місяців тому

      The buffer?

    • @Invictusxiv
      @Invictusxiv 8 місяців тому

      @@andy_plumbs Some departments have on their test sheets "buffer PSI" as it's main purpose is to see how much of pressure fluxuation there is, usually it has to be more than 3.0 psi from what I understand. Do you check the buffer on your tests? I have to in mystate/county.

    • @andy_plumbs
      @andy_plumbs 8 місяців тому

      @@Invictusxiv nope, never heard of it.

  • @JimmyBackflow
    @JimmyBackflow 8 місяців тому

    The differential across the second check valve differs from the differential pressure across the first check valve. Also, to backpressure the second check valve, the high control valve must be opened to introduce high pressure to the backside of the second check valve. Bad installation, no drain for catastrophic discharge. There are many problems with this video.

    • @andy_plumbs
      @andy_plumbs 8 місяців тому

      Are you saying the way I tested it was incorrect? I agree that the RP should be dumping to a drain but I didn’t plumb the building.

    • @JimmyBackflow
      @JimmyBackflow 8 місяців тому

      @@andy_plumbs To measure the differential pressure across the first check valve, connect the high-pressure hose to TC#2 and the low-pressure hose to TC#3, bleed out the air and take the reading. To backpressure the second check valve with the hoses still connected to TC#2 and TC#3, bleed the air out of the vent hose by opening the low control valve and connecting the vent hose to TC#4. Open the high control valve one complete turn and observe the relief valve. If there is no discharge, the second check valve is drip-tight with backpressure. To validate that backpressure was introduced behind the second check valve and not going downstream, close TC#2 and observe the gauge. If holding steady, the backpressure of the second check valve is confirmed, and the backflow preventer test was conducted when in a static state. To trigger the relief valve, open the low control valve one-quarter turn and observe the first drip. To test the DP across the second check valve, close TCs and remove hoses. Next, connect the high-pressure hose to TC#3 and the low-pressure hose to TC#4. Bleed and take the reading. It should be one psid or greater. I refer you to videos on UA-cam at jimmybakcflow.com. Also, the AWWA M14 manual has several test procedures, including the one I described. Testing is easy, but not done correctly causes concerns.

    • @andy_plumbs
      @andy_plumbs 8 місяців тому

      @@JimmyBackflow the procedure you’re describing is similar to how DC’s are tested, but I’ve never disconnected my hoses and jumped test cocks on a RP. I’ve always used the ASSE field test procedure book and it doesn’t mention anything of jumping test cocks either.

    • @JimmyBackflow
      @JimmyBackflow 8 місяців тому

      @@andy_plumbs To measure the DP across the RP second check valve, you must measure the pressure at TC#3 and TC#4. You will not see the steps described for measuring the DP across the second check valve because most test procedures and authorities do not require them. The problem occurs when testers fill out the form and put the DP of the first check valve in the second check valve box. This is a big problem in the industry because trainers do not explain how to measure the DP across the second check valve. If you want to measure the DP across the RP second check valve, do it correctly. If not, leave it blank. If you watch my videos, you will have a good understanding on how to test backflow preventers. The procedure is used through the NE States, NY, PA, and NJ and is outlined in the AWWA M14 Cross-connection Control Manual. Also, NEWWA provides a certification program for testing backflow preventers; a written copy of the test procedure is available.

  • @Swphoto800
    @Swphoto800 9 місяців тому

    Boy do I feel for this guy! Does it get any worse than this mess

  • @johnsouza4391
    @johnsouza4391 9 місяців тому

    First if original shower installer had realized the drain was directly over a joist, why didn't they just cut the joist and make a header to save the integrity of the framing. Instead they ruined a good joist and made for a terrible trap installation. Second, you are a very patient man. I hope you get paid well.

    • @andy_plumbs
      @andy_plumbs 9 місяців тому

      Yep, I have no idea what original installer was thinking. All I can do is make the best of it. And thank you, I have learned over the years that having patience is one of the most important traits to have in this trade.

  • @Pipesolutionsinc
    @Pipesolutionsinc 9 місяців тому

    What does something like that cost about 12 k?

    • @andy_plumbs
      @andy_plumbs 9 місяців тому

      We were a little less but not far off.

  • @johnmiller102
    @johnmiller102 9 місяців тому

    I'd like to see a tour of your van. It looks like you have it set up well.

    • @andy_plumbs
      @andy_plumbs 9 місяців тому

      Yeah, I get that request pretty often. I’m going to try to do a truck tour video soon!

  • @johnalbrecht4332
    @johnalbrecht4332 10 місяців тому

    Nice work and the truck looks awesome 👍

  • @mikev.1034
    @mikev.1034 10 місяців тому

    👍🤙🤘

  • @mikev.1034
    @mikev.1034 10 місяців тому

    👍👍

  • @thecatlady2710
    @thecatlady2710 10 місяців тому

    My shower drain cover needs to be removed so I can clean out the hair and gunk. There are no screws, I can't pry it up and it won't twist up. Any advice on how to get the thing off?

    • @andy_plumbs
      @andy_plumbs 10 місяців тому

      It is hard to say without seeing it. If it looks anything like the one in this video it should just pry up.

    • @thecatlady2710
      @thecatlady2710 10 місяців тому

      @@andy_plumbs Thank you so much! It does look like the one in your video. God bless you Sir! 👍

  • @kevinwilliams1421
    @kevinwilliams1421 10 місяців тому

    Don’t you own a bending machine..total amateur

  • @NoName-zz8nl
    @NoName-zz8nl 10 місяців тому

    Done this hundreds of times

  • @mycaddigo
    @mycaddigo 10 місяців тому

    Technically, shouldn’t that auto vent be up a bit higher? Preferably Just above the top of the sink?(maximum possible water level height)?

  • @Monkeywrench864
    @Monkeywrench864 10 місяців тому

    Let me know when the skill lvl starts. Handy man Saturday

  • @400080vikkash
    @400080vikkash 10 місяців тому

    Anytime the boss tells you it's supposed to only take an hr, this is the speed he's expecting you to work like.

  • @genevelis6075
    @genevelis6075 11 місяців тому

    I have a few questions, I wonder if you can help me to find answers: Thinking to lower the pressure tank and connect to the pump about 10' below the ground to eliminate the heating well house in the winter season. My pipe runs about 6' under the ground. 1) is it a good idea? 2) how to do it? 3) Should I install another pressure tank under the house in the crawl space? The well is about 30 yards away from the house. I found a 5" well in the field. PVC pipe broken, leveled with the ground. What to use to close it, to prevent from debris and rottens to fall down? How to find if it has water and how deep? Also what camera to buy to inspect the well? What 4" Submersible pumps and water pressure tank brands and models are best?

    • @andy_plumbs
      @andy_plumbs 11 місяців тому

      I would not recommend lowering the well tank. I understand the concern for heating the well house but it is going to be a logistical nightmare for you and future contractors that have to work on it. I would look into either having the well house professionally insulated or relocating the tank to inside the house or in the crawlspace. If the crawlspace is short I would look into a horizontal tank. As far as the abandoned well in the field, I would have a well drilling contractor check it out. There are legalities and liabilities involved with abandoning wells and they need to be backfilled and closed off properly.

    • @genevelis6075
      @genevelis6075 11 місяців тому

      @@andy_plumbs Thank you! I already dug 6' under the foundation, where the water pipe enters the house. So putting vertical pressure tank should not be a problem. A) the water coming from the well goes up and then down. Even if I put pressure tank under the house, I still need to heat well house in the winter. OR NOT? B) What filtration system should I put? And how about water goes to the hydrants. We have 5 of them. C) We have 20 gallon pressure tank. Is bigger the better? What brand would you recommend?

    • @andy_plumbs
      @andy_plumbs 11 місяців тому

      @@genevelis6075 if you have a submersible well pump in a casing then you can eliminate the well house by relocating the pressure tank. If you have a shallow well pump it’s a different story. I would have the water tested and treated accordingly. Most well systems require a softener at the very least, sometimes more filtration for iron or manganese. The hose spigots should not be filtered. Having a bigger tank isn’t necessarily always a good thing. It depends on your usage. Too small of a tank and your well pump will run more frequently. Too big of a tank and your drawn down cycle will last forever and it’ll seem like your pressure is weak at the lower end of the cycle. For more well related information I would check out H2o Mechanic’s channel. He has a lot of great videos on wells and everything that goes with them!

    • @genevelis6075
      @genevelis6075 11 місяців тому

      @@andy_plumbs Thank you so much! My well is about 150' deep if I remember correctly. The pump push water to the top and then back poly pipe goes down to the ground, branches out to hydrants and house. I already texted to H2O channel 3 times, this guy did not respond.

    • @andy_plumbs
      @andy_plumbs 11 місяців тому

      @@genevelis6075 that’s a bummer. Unfortunately my well knowledge is pretty limited. I would talk with your local well contractor and get their opinion. They should be able to provide an estimate also. I hope this helps.

  • @cspill99
    @cspill99 11 місяців тому

    Can you replace a cast iron house trap with a pvc house trap in michigan?