Chapter 2: Changing Line of Action of Force
Переглядів 915Рік тому
Chapter 2: Changing Line of Action of Force
Chapter 5: Equilibrium in 3 Dimensions
Переглядів 6312 роки тому
Chapter 5: Equilibrium in 3 Dimensions
METHOD OF JOINTS AND METHOD OF SECTION
Переглядів 8182 роки тому
METHOD OF JOINTS AND METHOD OF SECTION
AHHHHH KANINA PA KO NABABALIW SA 3-4-5 SIDE TRIANGLE EON LANG PALA YON TY SIRRR
Lakas
Well explained 👏 Thank you!
thank you so much Engineer!!!
sir tanong lang po, sa total service load po bakit hindi po included yung self weight nung beam?
@@jemsyvv well first, the given dead load is not “superimposed” hence we can conclude that it is total dead load. In board exam: the beam weight is not given, unless you memorized the whole weight then you can calculate the beam weight 😅 In actual design: As a designer, I know for sure, where those values came from hence, you know wether that given load includes selfweight or not.
Sir thank you for the video! may I ask if may sample problem po kayo for compression
baka ikaw lg tgalaga ung nakita kong may porblem solving sa gantong topic sa steel huhuhu. salamat po kaso iba lang pagkaka solve kasi ibang book ung base nyo kami kasi nscp so nominal hole diameter plus 2 talaga kami salamat po
@@jgja1931 the 2mm additional states in NSCP is same in AISC (1/16”) which for standard holes. However, NSCP did not include the commentary in AISC which also states that additional 1/16” shall be added for damage related in punching or drilling of holes. Hence the effective hole shall be. Diamter of bolt + 1/16” (standard hole) + 1/16” for damage allowance. Or Diamter of bolt + 1/8”. Technically, by converting it is db+ 3.175mm. Hope it clears your doubt. ☺️
hello sir, ask ko lang po if same sila sa AISC po. salamat po.
Yes po
saan po kayo na RC nagtuturo engineer?
@@klaycurry-d9x di n po ako affiliated sa review center hehe
ang masasabi ko ay sheeeshhh solid!!!
sir bakit tensile = 0.3108 yung result if i-input yung values sa calculator?
Maayos ang pagkakaturo sir. Thank you po!
Doubts cleared, but what language is that
@@carlosvargas1331 Filipino/Tagalog
thank you sir !!
Pogi mo talaga master
Hi Engr, nagtuturo ka ba ng staad and revit?
@@janmariposquefamily Only Midas sir
Ok sir. How much po ang lesson and ano sir inclusions?
Awesome explanation
NSCP 2001 po ba ito sir?
Perfect work 🙏🏻, thank you
Many thanks 🙏🏻
Many thanks 🙏🏻
Many thanks 🙏🏻
ang pangarap kong program >.<
Thank you for uploading sir, balik ako dito next next week. #RCEnaAPRIL2024! In Jesus Name!
Saan nakuha yung 3.2 sa unang problem
based sa nscp code 2001, use 4 na lang po, yun po for nscp 2015
Question lang po. Ano po bang ginagamit na basehan sa pagkuha po ng Fy from table 2-4 ng astm manual? Ang turo po kasi ng prof namin is width daw po ang pinagbabasihan non kaya po sa lecture namin, 32 po ang pinagamit na Fy pag ang width po ay equal otñr less than 8 tas napanood ko naman po sa mga sample problems dito sa yt kahit over 8 po yung width ng plates or bars 36 pa rin po ginagamit na Fy. 13th edition po gamit namin na aisc manual. Sana po masagot quiz na po kasi namin sa isang araw hehe, thank youuu
13:05 engr. tanong ko lang po if pwede sa rupture on net area pag ang cut ay sa path f-g?
super useful parin hanggang ngayon haha di kana mamomroblema isang panood lang gets agad, galing mo sir! thanksss ❤
hello po sir tanong ko lang po bakit +3 po yung 18mm bolt? kasi according sa NSCP 2015 (table 510.3.3) ito po yung recommended,na kapag ang bolt diameter is M16-M22 is +2 lang po, then kapag M24-M35 is +3 po... bakit po +3 po sayo eh M18 bolts lang po yan... ask ko lang po, thank you po
saang book po kayo nagbase ng problems?
Ang daming ads, exam ko na mamayang 9am huhu
thank you po sir!
شكرا جزيلا
gusto ko lang po sabihin sir na thank you so muuuuch po sa video nyo sa steel. sobrang na gets kopo sya and nakakaya kopo sagutan mga problem sets na bigay ni sir radger.
Sa unang 4:30 minutes po bakit po ulit nag add ng 3.2 😢 huhu sana po masagot
based sa nscp code 2001, use 4 na lang po, yun po for nscp 2015
Diba po 2001 yang 3.2 at yung 2010/2015 ay 4mm na po ang iadd?
paano nakuha yung s²/4g sir
Sir June, down na po yung link. pwede po pa Re Up. thank you
Hello sir. Saan video po na discuss yung stiffened and unstiffined? Thanks
Sa dami kong napanood ito lang yung na gets ko
Good day po sir, meron po ba kayong link ng table para sa WT? or Kung meron pong manual way para ma compute sya
sir available pa po ba yung file? di ko na po kasi ma download
Good day Engr. Santos, sir please upload or update your playlist po sa steel design. Sobrang linaw po kasi ng turo nyo. Kelangan na kelangan lang po pumasa sa steel. Thank you po
Good day po Engr. Santos. May I ask po sir kelan kayo mag a-upload ng other videos nyo dito sa playlist ng steel design? sobrang need lang po. Thank you :)
pwede po makahingi ng file ng aisc manual niyo po, yung compiled na
sir may ma recommend po ba kayo books for rcd and steel?
San po nakuha ung 3.2?
Ty po engr. Pumasa napo ako
Congratulations engineer 😊😊😊
Thank you very much sir june sa series of free lecture nyo, parte po kayo ng pagiging RCE ko. More power and God bless po sir! ❤️
Congratulations engineer!!!! 😊😊😊
Correct me if I'm wrong sir. If the diameter hole only I think we need to add 1/16 inch or around 1.6mm in SI but others rounded it up to 2mm to make it more conservative. And if diameter bolt was given we have to add 1/8 inch (twice of 1/16) or around 3.2mm and so others also used 4mm to get the most critical net area.
Yes you may.