Structural Systems Laboratory
Приєднався 26 сер 2013
Dissemination of information from the Structural Systems Laboratory at the University of Notre Dame
Seven-wire strand break
Testing of Seven-Wire Post-Tensioning Strand for Free Length Failure
Переглядів: 6 455
Відео
Testing of a Post-Tensioned Coupled Shear Wall System (Specimen 2 North Overall)
Переглядів 80410 років тому
Specimen 2 Overall (North) View - Entire Test This project, funded by the U.S. National Science Foundation and titled "NEESR-CR: Post-Tensioned Coupled Shear Wall Systems," is developing experimentally-validated seismic design procedures and modeling/prediction tools for post-tensioned coupled shear wall structures. The project includes the University of Notre Dame, the University of Texas at T...
Testing of a Post-Tensioned Coupled Shear Wall System (Specimen 2 South Base)
Переглядів 71310 років тому
Specimen 2 Base Story (South) Performance During Roof (8th Floor) Drift Cycles of 1.35% through 3.00% This project, funded by the U.S. National Science Foundation and titled "NEESR-CR: Post-Tensioned Coupled Shear Wall Systems," is developing experimentally-validated seismic design procedures and modeling/prediction tools for post-tensioned coupled shear wall structures. The project includes th...
Buckling of a High Strength, Concentrically Loaded RC Bearing Wall under Fire Exposure
Переглядів 3,7 тис.11 років тому
This project, funded by the National Science Foundation, has been investigating the effect of fire on the behavior of reinforced concrete bearing wall systems. Reinforced concrete bearing walls are one of the most common primary load-resisting components in building structures such as hospitals, hotels, offices, and condominiums. The walls carry much of the self-weight and other gravity loads o...
Buckling of a Normal Strength, Concentrically Loaded RC Bearing Wall under Fire Exposure
Переглядів 56811 років тому
This project, funded by the National Science Foundation, has been investigating the effect of fire on the behavior of reinforced concrete bearing wall systems. Reinforced concrete bearing walls are one of the most common primary load-resisting components in building structures such as hospitals, hotels, offices, and condominiums. The walls carry much of the self-weight and other gravity loads o...
Super Video, danke dafür! Egal wo es hingehen soll: Auf www.urlaubsgranaten.de klicken Sie sich in wenigen Sekunden ins Urlaubsparadies - all-inclusive oder Last-Minute www.urlaubsgranaten.de
Excellent presentation
Great video... thanks for sharing.
Hope she’s not paid by the hour, I coulda taken a strand to max and snapped it for ya in a minute 😂
What is the materials with the combine of brown particles for adtl grip?
Thanks for loading - I used part of your video for educational purposes - enjoy and thank you for your post - I do appreciate them. ua-cam.com/video/W6hNYpPdUsQ/v-deo.htmlm26s
Nicely done, thanks for this. So explosive spalling at about 5 minutes of 1200F and total failure at 70 minutes? This would be considered "high-strength" concrete -- correct? *Other* than at or in the furnace, where was temperature measured? Air? at concrete surface? Any sub-surface probes?
Very interesting work! Fantastic!