LeTomas AHUMADA
LeTomas AHUMADA
  • 424
  • 811 083
Training - M221 - M21.6 Trace (Using Animation Table)
Training - M221 - M21.6 Trace (Using Animation Table)
The software EcoStruxure Machine Expert Basic (former SoMachine Basic) allows you to program the Modicon M221:
www.se.com/ww/en/download/document/Machine_Expert_Basic/
The software EcoStruxure Machine Expert Basic is Free, you need to have an account in our License Portal in order to register it:
www.se.com/ww/sites/corporate/en/support/software-licensing/user-login
In order to program the Modicon M221 you can use a miniUSB cable (TCSXCNAMUM3P or BMXXCAUSBH018).
Playlist of the training:
ua-cam.com/play/PLFqT6GhMpgpLClSpB1iH50OUr4N4mU763.html
Переглядів: 0

Відео

Training - M221 - M18.3 Internal variable bits inside User Defined Functions Blocks
Training - M221 - M18.3 Internal variable bits inside User Defined Functions Blocks The software EcoStruxure Machine Expert Basic (former SoMachine Basic) allows you to program the Modicon M221: www.se.com/ww/en/download/document/Machine_Expert_Basic/ The software EcoStruxure Machine Expert Basic is Free, you need to have an account in our License Portal in order to register it: www.se.com/ww/s...
EcoStruxure Machine Expert Training - Mx.x Reading real variable in a network (32bits variables)
EcoStruxure Machine Expert Training - Mx.x Reading real variable in a network Library SE_LTA : app.box.com/s/r7zupob3dtzzds51pcksqywy6qgasbr8 The software to program the Modicon M241, M251, M258, M262 and PacDrive MotionController is EcoStruxure Machine Expert (former SoMachine / SoMachine Motion). For the Modicon M258 the version required to use the software is the EcoStruxure Machine Expert v...
Training EcoStruxure Operator Terminal Expert - Mx.x How to use BlockTrend
Переглядів 15714 годин тому
Training EcoStruxure Operator Terminal Expert - Mx.x How to use BlockTrend EcoStruxure Operator Terminal Expert (former Vijeo XD) is the software that allow us to program the Harmony HMIs like: •HMISTO7: (not the HMISTO5 or HMISTU) download.schneider-electric.com/files?p_Doc_Ref=DIA5ED2130607EN •HMIST6 / HMISTM6: download.schneider-electric.com/files?p_Doc_Ref=DIA5ED2181202EN •HMIGTU: download....
Training TeSys Island - M3.4 Firmware (Upgrade/Downgrade using SoMove)
Переглядів 68День тому
Training TeSys Island - M3.4 Firmware (Upgrade/Downgrade using SoMove) TeSys™ island is an innovative digital load management solution, providing data for higher machine efficiency and ease of servicing, and allowing faster time to market. TeSys island is a modular, multifunctional system providing integrated functions inside an automation architecture, primarily for the direct control and mana...
Training - M221 - M14.4 Linking variables to EcoStruxure Operator Terminal Expert
Переглядів 23314 днів тому
Training - M221 - M14.4 Linking variables to EcoStruxure Operator Terminal Expert The software EcoStruxure Machine Expert Basic (former SoMachine Basic) allows you to program the Modicon M221: www.se.com/ww/en/download/document/Machine_Expert_Basic/ The software EcoStruxure Machine Expert Basic is Free, you need to have an account in our License Portal in order to register it: www.se.com/ww/sit...
Training EcoStruxure Operator Terminal Expert - Mx.x Visibility depending on User Level
Переглядів 15621 день тому
Training EcoStruxure Operator Terminal Expert - Mx.x Visibility depending on User Level EcoStruxure Operator Terminal Expert (former Vijeo XD) is the software that allow us to program the Harmony HMIs like: •HMISTO7: (not the HMISTO5 or HMISTU) download.schneider-electric.com/files?p_Doc_Ref=DIA5ED2130607EN •HMIST6 / HMISTM6: download.schneider-electric.com/files?p_Doc_Ref=DIA5ED2181202EN •HMIG...
Training Aveva - InTouch -Integration Modicon M262 using OPC UA driver
Переглядів 267Місяць тому
Training Aveva - InTouch -Integration Modicon M262 using OPC UA driver Schneider Electric and AVEVA enable us to maximize value from our industrial, data center and infrastructure assets. Their longstanding partnership, combined with Schneider Electric integrated digital transformation solutions, brings together energy management and automation tools with leading-edge industrial software that s...
Training - M221 - M6.8 Data Logging
Переглядів 317Місяць тому
Training - M221 - M6.8 Data Logging The software EcoStruxure Machine Expert Basic (former SoMachine Basic) allows you to program the Modicon M221: www.se.com/ww/en/download/document/Machine_Expert_Basic/ The software EcoStruxure Machine Expert Basic is Free, you need to have an account in our License Portal in order to register it: www.se.com/ww/sites/corporate/en/support/software-licensing/use...
Modicon M580 - How to upgrade firmware from v3.x to v4.x
Переглядів 104Місяць тому
Modicon M580 - How to upgrade firmware from v3.x to v4.x
Training EcoStruxure Operator Terminal Expert - Mx.x Visualize analog values using a Gauge
Переглядів 334Місяць тому
Training EcoStruxure Operator Terminal Expert - Mx.x Visualize analog values using a Gauge EcoStruxure Operator Terminal Expert (former Vijeo XD) is the software that allow us to program the Harmony HMIs like: •HMISTO7: (not the HMISTO5 or HMISTU) download.schneider-electric.com/files?p_Doc_Ref=DIA5ED2130607EN •HMIST6 / HMISTM6: download.schneider-electric.com/files?p_Doc_Ref=DIA5ED2181202EN •H...
ESME HVAC - Communication - M6.4 EcoStruxure Operator Terminal Expert )(Modbus Serial)
Переглядів 183Місяць тому
ESME HVAC - Communication - M6.4 EcoStruxure Operator Terminal Expert )(Modbus Serial) The software to program the Modicon M171/M172 is EcoStruxure Machine Expert HVAC (former SoMachine HVAC). The software can be downloaded from our website: www.se.com/uk/en/download/document/SoMachine HVAC - Programming Software for Modicon M171-M172 Logic Controllers/ The EcoStruxure Machine Expert HVAC is fr...
ESME HVAC - Communication - M5.1 CanBinding Configuration
Переглядів 135Місяць тому
ESME HVAC - Communication - M5.1 CanBinding Configuration The software to program the Modicon M171/M172 is EcoStruxure Machine Expert HVAC (former SoMachine HVAC). The software can be downloaded from our website: www.se.com/uk/en/download/document/SoMachine HVAC - Programming Software for Modicon M171-M172 Logic Controllers/ The EcoStruxure Machine Expert HVAC is free but the user will need to ...
ESME HVAC - Communication - M6.3 EcoStruxure Operator Terminal Expert (ModbusTcp)
Переглядів 1592 місяці тому
ESME HVAC - Communication - M6.3 EcoStruxure Operator Terminal Expert (ModbusTcp) The software to program the Modicon M171/M172 is EcoStruxure Machine Expert HVAC (former SoMachine HVAC). The software can be downloaded from our website: www.se.com/uk/en/download/document/SoMachine HVAC - Programming Software for Modicon M171-M172 Logic Controllers/ The EcoStruxure Machine Expert HVAC is free bu...
Training EOTE - Script Block - M4.9 Web Browser
Переглядів 1472 місяці тому
Training EOTE - Script Block - M4.9 Web Browser EOTE = EcoStruxure Operator Terminal Expert EcoStruxure Operator Terminal Expert (former Vijeo XD) is the software that allow us to program the Harmony HMIs like: •HMISTO7: (not the HMISTO5 or HMISTU) download.schneider-electric.com/files?p_Doc_Ref=DIA5ED2130607EN •HMIST6 / HMISTM6: download.schneider-electric.com/files?p_Doc_Ref=DIA5ED2181202EN •...
Training EOTE - Script Block - M4.8 Launch Application
Переглядів 2162 місяці тому
Training EOTE - Script Block - M4.8 Launch Application
Modicon M173 - Getting started
Переглядів 2992 місяці тому
Modicon M173 - Getting started
Training TeSys Island - M8.6 Integration with Modicon M580 (SNTP)
Переглядів 1012 місяці тому
Training TeSys Island - M8.6 Integration with Modicon M580 (SNTP)
Training TeSys Island - M8.5 Integration with Modicon M580 (Energy and Power)
Переглядів 922 місяці тому
Training TeSys Island - M8.5 Integration with Modicon M580 (Energy and Power)
Training TeSys Island - M8.4 Integration with Modicon M580 (Maintenance and Product Data)
Переглядів 982 місяці тому
Training TeSys Island - M8.4 Integration with Modicon M580 (Maintenance and Product Data)
Training TeSys Island - M8.3 Integration with Modicon M580 (Control)
Переглядів 1313 місяці тому
Training TeSys Island - M8.3 Integration with Modicon M580 (Control)
Training TeSys Island - M8.2 Integration with Modicon M580 (Connection)
Переглядів 1573 місяці тому
Training TeSys Island - M8.2 Integration with Modicon M580 (Connection)
M172 Secure Interface - Mx.x Configuration solution EcoStruxure Secure Connect
Переглядів 1733 місяці тому
M172 Secure Interface - Mx.x Configuration solution EcoStruxure Secure Connect
M172 Secure Interface - Mx.x Introduction to EcoStruxure Secure Connect
Переглядів 1303 місяці тому
M172 Secure Interface - Mx.x Introduction to EcoStruxure Secure Connect
M172 Secure Interface - Mx.x First connection (via miniUsb)
Переглядів 2143 місяці тому
M172 Secure Interface - Mx.x First connection (via miniUsb)
ESME HVAC - Communication - M2.5 Modbus Tcp Template Device
Переглядів 1103 місяці тому
ESME HVAC - Communication - M2.5 Modbus Tcp Template Device
ESME HVAC - Communication - M2.4 Modbus Tcp IOScanner Troubleshooting
Переглядів 963 місяці тому
ESME HVAC - Communication - M2.4 Modbus Tcp IOScanner Troubleshooting
ESME HVAC - Communication - M2.3 Modbus Tcp IOScanner Implementation
Переглядів 1153 місяці тому
ESME HVAC - Communication - M2.3 Modbus Tcp IOScanner Implementation
ESME HVAC - Communication - M2.2 Modbus Tcp Function Blocks
Переглядів 1674 місяці тому
ESME HVAC - Communication - M2.2 Modbus Tcp Function Blocks
ESME HVAC - Communication - M2.1 Configuration Ethernet Port (Client / "Master" )
Переглядів 1384 місяці тому
ESME HVAC - Communication - M2.1 Configuration Ethernet Port (Client / "Master" )

КОМЕНТАРІ

  • @GerhardBothaWFF
    @GerhardBothaWFF 4 години тому

    Jump is like goto… 99% of the time it is a sign of bad programming

  • @Luiz_Baron
    @Luiz_Baron 6 годин тому

    Leandro, When connecting the PLC M221 to an HMI-ET6600 with Modbus TCP, do I need to do this configuration as well?

  • @adrian3881-s9g
    @adrian3881-s9g День тому

    Hello is posible conect with a triconex ??

  • @samwyard
    @samwyard 2 дні тому

    Hi Leandro, me again, love these videos and they have helped me greatly with me adding additional functionality to my HMI program, i have a question regarding Export Data/Export Status no.1) has the new update of EOTE in regards to export data put a block on starting the HMI program is data storage is set to USB storage and no USB is present? seems to be the case and i have to revert back to internal storage to get the program to load (an error message to that affect is shown) no.2) do you have a video on Export Status yet? looking to add function to my trend screen when running export command, would like to show if successful or not and give error code if usb is not present or corrupt etc. TIA sam

  • @Industria-ProfInstalacionesSRL

    BUENAS TARDES, MI CONSULTA ES COMO HICISTE PARA AGREGAR EL CONTROLADOR Y EL DISPLAY REMOTO EN EL MISMO PROGRAMA

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 4 дні тому

      Buenas! Mirate el siguiente video para la full explanation: EcoStruxure Machine Expert HVAC Training - M2.1 Creating a project ua-cam.com/video/bH7jE7Hxg4I/v-deo.html Basicamente tenes que usar el installer para tener varios plcs pero el codigo se puede abrir de a uno

  • @slucasanjos
    @slucasanjos 4 дні тому

    Good afternoon. Is there a way to create an internal Boolean variable? Are the types only Word, Double and Float?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA День тому

      Hi There! you can create a word variable then access to the each of the bits of that word. For example Variable called "Hello" you can use the %HELLO:X0 to %HELLO:X15 to access the bit0 to bit15 of that word. I have created a video for this available next week: ua-cam.com/video/CLhor5K3-zY/v-deo.html

  • @anisbelghanem9140
    @anisbelghanem9140 4 дні тому

    Hi LeTomas, thank you for you work! When i press "generate code", the xml file is not generated in the folder, do you have an idea of what the problem could be ?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA День тому

      Hi There! I believe it could be: 1) you have errors in your code that are not allowing you to generate the file 2) you have not selected anything on the "Symbol Configurator" 3) You have not used any of the variables on the GVLs

  • @abak0_0
    @abak0_0 5 днів тому

    Hello, Leandro! An error occurred when adding HMIET6400 in the Expert Machine v2.2 program. Vijeo Designer basic 2.0 is installed, I tried to install version 6.3, but it didn't help. Is it possible that the error is related to the wrong choice of HMI, since I did not find my HMIET in the Expert Machine and chose a similar one. The type of connection via an Ethernet cable. I also can't add the ATV 320, the error is the same related to vijeo designer. That's what the error says "vijeo designer is either not installed on your computer or it is not supported by the used ecosruxture machine expert license

  • @rodrigodomingues18
    @rodrigodomingues18 5 днів тому

    From what I've seen it cannot be a structure where I want M[1].Speed and M[2].Speed. It needs to be straight up a value in the address

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 5 днів тому

      Hi there! I have not tested that but you can create an array as i did in the video and then bind your structure to the element in the arrays.

  • @tarekbenhacine8743
    @tarekbenhacine8743 5 днів тому

    Thank you. What are the reference for the drive and stepper motor are you using ?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 5 днів тому

      Hi there! If i am not wrong is a Lexium 32 range but i do not remember the exact part number for the solution.

    • @tarekbenhacine8743
      @tarekbenhacine8743 5 днів тому

      Thank you

  • @Mikola_Naumenko
    @Mikola_Naumenko 6 днів тому

    👍👍👍👍👍

  • @fernando36881
    @fernando36881 10 днів тому

    Hi Thomas Can you create video about legacy PLC like M218 and M238 how to add in Somachine?

  • @Luiz_Baron
    @Luiz_Baron 10 днів тому

    Congratulations Leandro, your videos are helping a lot. One question, can I use the Trace function to generate a graph of an analog variable?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA День тому

      Hi There! Using the trace you can visualize inside the software how a analog/digital variable change over time. I have created a video how to use only the trace: ua-cam.com/video/6gKfUPFotaw/v-deo.html But i believe on the video M3.3 it shows in details.

  • @rodrigodomingues18
    @rodrigodomingues18 12 днів тому

    Do you or anyone from schneider have a video of Block Trend object?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 12 днів тому

      Hi there! I will create one for next week.

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 10 днів тому

      ua-cam.com/video/4-XgnfHg0Ug/v-deo.html

  • @Mikola_Naumenko
    @Mikola_Naumenko 13 днів тому

    Hello.😊😊😊

  • @APITAutomation
    @APITAutomation 15 днів тому

    I have already created screen designs for hmist6400 but now I have upgraded to hmist6600. How do I change the resolutions of all the screen designs to new hmi?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 12 днів тому

      Hi there! As far as I know with this version of the software there is not an automatic resize of the screens. I always advise to create view box contents so you can easily resize up or down.

  • @Mikola_Naumenko
    @Mikola_Naumenko 16 днів тому

    🤓

  • @milindagunawardhana1809
    @milindagunawardhana1809 17 днів тому

    Hi ,how we can do animation of images easily (ex- want to show rotation of motor/ pump/mixer)

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 17 днів тому

      Hi there! you can try these two videos: 1) ua-cam.com/video/ZWeGEnbfC8U/v-deo.html 2) ua-cam.com/video/jvEyc59Qu2o/v-deo.html

    • @milindagunawardhana1809
      @milindagunawardhana1809 17 днів тому

      @@LeTomasAHUMADA thanks 🙏🙏

  • @adamrisky1558
    @adamrisky1558 18 днів тому

    can you tell me why my download icon is cannot be touch, i'm trying to download the program into the HMI

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 18 днів тому

      Hi there! I believe it is because you are using the trial version of the software. You must have a license.

  • @pedroborges2672
    @pedroborges2672 19 днів тому

    I used the tcp io scanner on the m221 to read and write on the m340 and I couldn't write and read on the m340 what way should I communicate on the m221 to read and write on the m340 ?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 17 днів тому

      Hi there! It should work (assuming you are connecting to the ritgh ports). Try reading just one word from the m340 and check on the m340 the previous and next position just in case

  • @petrurahovan5112
    @petrurahovan5112 19 днів тому

    Salut am conectat atv 320u22n4c cu tm221c24t apare eroare Io scanner error

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 16 днів тому

      Hi there! The error could be related to many things: 1) Wrong modbus serial cables pinouts. 2) Mismatch configuration of the modbus serial in both devices. 3) wrong ioscanner device selected. 4) no configuration in the drive to be control via comm. Those are the common ones to check

    • @petrurahovan5112
      @petrurahovan5112 16 днів тому

      @@LeTomasAHUMADA am rezolvat mulțumesc oricum

  • @anisbelghanem9140
    @anisbelghanem9140 19 днів тому

    Hello brother, when i add the "Symbol Cnfiguration" (3:49), the GVL i created doen't apear on the list, can you tell me how can i fix this please ?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 16 днів тому

      Hi there! It could be that the GVL with your variables none of them is used in a POU.

  • @samanabdullah8408
    @samanabdullah8408 21 день тому

    Hi sir , i use ATV320 , when frequency above 4 Hz the screen display 50C ?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 10 днів тому

      Hi there! Have you connect to the drive using somove for further info?

  • @rahulsurendran3472
    @rahulsurendran3472 21 день тому

    Thank you for the videos.Can you please create same type of lectures on Control expert

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 11 днів тому

      Hi There! I am working on that for 2025 :)

  • @Djunaidilim0875
    @Djunaidilim0875 22 дні тому

    Thanks, can you explain how to read kwh 4 words/64 bit uint data

  • @JoãoMatos-z9x
    @JoãoMatos-z9x 23 дні тому

    Hi do you have some example of a ftp file transfer from a plc to a ftp server

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 23 дні тому

      Hi there! I played with the m251 and FileZilla but i will need to make a video, which plc are you working with?

    • @joaomatos4652
      @joaomatos4652 21 день тому

      @@LeTomasAHUMADA Hi I’m using a m262 and I need also to a M241

    • @joaomatos4652
      @joaomatos4652 21 день тому

      These are the both models that I normally use I test one example in the past and I was using the xlight server ftp and was working but now is no more working. Is giving a error of library

  • @KrishnaModi-b3u
    @KrishnaModi-b3u 23 дні тому

    Hi, How to get communication lost between 2 PLC's while data sending/receiving via NVL?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 23 дні тому

      Hi there! If i am not wrong there is a function block for NVLs but i share an additional variable that change the value and if it does not change then there is a problem

    • @KrishnaModi-b3u
      @KrishnaModi-b3u 23 дні тому

      ​@@LeTomasAHUMADA Yes, found function block "NETVARGETDIAGINFO" for this. Thanks!!!

  • @samanabdullah8408
    @samanabdullah8408 25 днів тому

    for communication via IOScanner both devices must have IOScanner protocol (plc and atv,hmi,power meter ,---)?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 24 дні тому

      Hi there! Only the master/client can have the IOscanner then the slave needs to be compatible with the modbus functions. Some slave/server like the ATV has a mapped area for the ioscanner to easily read/write contiguous variables to optimize the channel.

  • @samanabdullah8408
    @samanabdullah8408 25 днів тому

    Hi sir, if we have two plc model M221 communicate via IOScanner , variable bust be %mw or anthers like %mf has not problem , can you explain it?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 24 дні тому

      Hi there! If i am not wrong only %MW variables are allow in the ioscanner but you can sent two mw to form the %mf. You can check the next video for guidance: ua-cam.com/video/kZul3e6Q_Rg/v-deo.htmlsi=lqu32IkVCRZKsgNK

  • @Djunaidilim0875
    @Djunaidilim0875 26 днів тому

    THanks Thomas for clear explanation. How to read KWH 64 bits ? can you give some example

  • @revitalize-se
    @revitalize-se 27 днів тому

    Hello LTA, I’m having difficulty simulating the software EcoStruxure Operator Terminal Expert and Machine Expert Basic. I can't simulate communication between them on the PC. Is it possible to make the two simulators communicate with each other? I watched your video about variable linking with the M221, but in my case, I’m using an M200, and even with the online simulation, I can't make them communicate. Is there any procedure or something I can do? I don't know why, but it’s just not working for me.

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 12 днів тому

      Hi there! I have created a new video just in case: Training - M221 - M14.4 Linking variables to EcoStruxure Operator Terminal Expert ua-cam.com/video/n8RDMkQUlg8/v-deo.html Make sure you are using “simulate” rather than “device simulate” on the hmi.

  • @mikefreedom5612
    @mikefreedom5612 27 днів тому

    🎉🎉🎉🎉

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 27 днів тому

      If there is any specific content required let me know

  • @aminudinamin6251
    @aminudinamin6251 27 днів тому

    Sometimes, output string time from FB_DT is hh:mmss, normally is hh:mm:ss Need your help, thanks.

    • @aminudinamin6251
      @aminudinamin6251 27 днів тому

      if minute <10, output hh:mss if minute >10, format hh:mm:ss

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 27 днів тому

      Hi there! I will check the code but can you give me an example when that happens?

    • @aminudinamin6251
      @aminudinamin6251 27 днів тому

      @@LeTomasAHUMADA I made a program, one of which is reading time using FB_DT. for example, if the time is 13:30:52, the output string from FB_DT is "13:30:52". However, if the time is 08:07:05, the output string from FB_DT is "875". the ":" character is not visible.

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 25 днів тому

      Hi There! You are right. I have checked it and updated the library: app.box.com/s/j45enur48dzxa602gdeg083jmhwt8p3s Now it works!

  • @mikefreedom5612
    @mikefreedom5612 28 днів тому

    🎉🎉🎉🎉

  • @vuquang6651
    @vuquang6651 Місяць тому

    Thanks your Video.Can i ask, Modbus Serial Function Blocks can be config polling time same modbus serial IOScanner? How to config this

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 28 днів тому

      Hi there! You will need to use the EN of the block to define the frequency of the execution.

    • @vuquang6651
      @vuquang6651 28 днів тому

      @@LeTomasAHUMADA i have 20 devices and read 8 registers 1 function block, so do i need to hold EN for long enough to read. thanks for your reply

  • @viktorlovas7727
    @viktorlovas7727 Місяць тому

    Dear LeTomas AHUMADA! Thanks for this detailed tutorial. A question: is that powerPoint presentation you showed from 6:45 also available? Thanks in advance.

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 28 днів тому

      Hi there! All the ppts prepared are only for me to make the content in the videos. Best regards,

  • @marcfruchtman9473
    @marcfruchtman9473 Місяць тому

    I tend to "skim" over sections in the video like "how to press the help button", since those are obvious! BUT, I WAS WRONG to just skim over it. That Contextual Help option is really useful. Thank you for going over it in the video.

    • @LeTomasAHUMADA
      @LeTomasAHUMADA Місяць тому

      Hi there! that contextual help is very usefull to easily access to the help of the element selected. Thanks for not skipping :)

  • @petrurahovan5112
    @petrurahovan5112 Місяць тому

    Salut ca sa conectezi pc cu altivar 320 trebuie cablu special ,multunesc

    • @LeTomasAHUMADA
      @LeTomasAHUMADA Місяць тому

      Hi there! If the ethernet comm card is not installed in the atv320 then you need the programming cable TCSMCNAM3M002P. In the pc you need the atv320 dtm from se.com

    • @PetruRahovan
      @PetruRahovan Місяць тому

      Mulțumesc mult dtm am înseamnă că trebuie cablu mulțumesc

    • @LeTomasAHUMADA
      @LeTomasAHUMADA Місяць тому

      @@PetruRahovan just in case the link for the DTM: se.com/uk/en/download/document/ATV320_DTM_Library/

  • @alexanderkiselyov
    @alexanderkiselyov Місяць тому

    Hello, sir. I'm new to M172. Did exactly the same shown in your video, but i can't find my device on BACnet with Yabe. I also tried to load example project from BACnet Addons library, but still nothing on BACnet. Maybe I'm missing something basic.

    • @LeTomasAHUMADA
      @LeTomasAHUMADA Місяць тому

      Hi there! Have you tried the example from the library on the description? Remember to activate the BACnet port because by default is disabled.

    • @alexanderkiselyov
      @alexanderkiselyov Місяць тому

      @@LeTomasAHUMADA just tried the example from the description still no communication on BACnet. BIOS Parameter Port_BACnet_IP is set to 47808 or there is anything else I should do to enable it?

    • @alexanderkiselyov
      @alexanderkiselyov Місяць тому

      My bad. Messed up with IP settings on my laptop. Now everything works fine.

    • @LeTomasAHUMADA
      @LeTomasAHUMADA Місяць тому

      @@alexanderkiselyov glad that is working now 💪🏻🎉

  • @marcfruchtman9473
    @marcfruchtman9473 Місяць тому

    Thank you for the video. It was very helpful especially in figuring out the UI elements. As far as I know, It is not good practice to use Normally Open switches for "Stop" functionality. If the wire connected to the switch breaks, there would be no way to stop the conveyor quickly. The person would then have to look for a disconnect or the e-stop, which hopefully was not also wired normally open. It might be worth noting that there's a good bit of audio static in this video for some reason too.

    • @LeTomasAHUMADA
      @LeTomasAHUMADA Місяць тому

      Hi there! Thank you for your feedback. As you mentioned all stop switches must be NC.( to be honest i do not remember what i have done on this video 😅) Regarding the audio it is related to the bad mic that i used …you can check that i had hair at that time 🙃 I will probably create a newer training with better video and audio. Thanks! 💪🏻

    • @marcfruchtman9473
      @marcfruchtman9473 Місяць тому

      @@LeTomasAHUMADA Thank you for the reply. New Vids based on an updated Conveyor project would be a welcome addition.

  • @samanabdullah8408
    @samanabdullah8408 Місяць тому

    Hi Mr.LTA , if the offset of is real value like temperature degree (32.5)c , we can define IWN100.X.X to %mfx ?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA Місяць тому

      Hi there! I usually move the value to a %MW and then the converter int_to_real for the %MF

  • @tiagosoaresmenezes
    @tiagosoaresmenezes Місяць тому

    Thank you is not enough! My congratulations for the best playlist about EAE.

  • @jianpingli3826
    @jianpingli3826 Місяць тому

    great! recently bought a m262 plc starter kit, and trying to follow your lessons here. Thanks.

    • @LeTomasAHUMADA
      @LeTomasAHUMADA Місяць тому

      Hi JP! I am glad you got the kit to “play” with the M262 😊🎉

  • @hyungraelee1334
    @hyungraelee1334 Місяць тому

    혹시 슈나이더 직원이신가요?

  • @ahmadmohamed3645
    @ahmadmohamed3645 Місяць тому

    Hi LeTomas, great info. Very helpful. Please explain what are the means of this address (MW10:X0 ) in the ladders?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA Місяць тому

      Hi there! It means that you are accessing to the bit 0 of the memory word %MW10 (bit addressing in a word)

  • @HyperMAX9001
    @HyperMAX9001 Місяць тому

    Thank you for this tutorial! We are starting to use SDs to log data and it's very useful. I have a question, does it save those backup files up to filling the entire SD card or it makes only one datalog and one backup, each max 500kB?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 28 днів тому

      Hi there! Good question, i tried a long time ago…and i believe you must have a unique file of 500kb max per datalog

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 28 днів тому

      If you can test it will be great 😅

  • @samanabdullah8408
    @samanabdullah8408 Місяць тому

    Thanks, why you write %mw62 instead of %m62 for back light , is not digital out put ?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 28 днів тому

      Hi there! The backlight in the m172 requires a word variable that is why.

  • @CharlesDickens1995
    @CharlesDickens1995 Місяць тому

    Hi Leandro, I'm working with visualizations in machine expert as part of a project that uses lots of images (and resources). After the last update I made for a client, they commented to me that there were issues related to "the machine freezing". When I inspected the issue, I realized this problem was related to the refresh rate/interval of the visu task manager as the visualizations were consuming a LOT of resources. The PLC was reaching 85% usage and then went into fault mode. I increased the refresh rate from 20 to 175ms (visu task interval) and it got solved. However, after one week the client told me there were some issues with buttons becoming gray after a few minutes not using the equipment (HMI) and I don't know how is that even happening. The tick on "paint disabled elements grayed out" is active but that never meant a problem before. Is there anyway I can reduce the consumption of resources? Cheers

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 27 днів тому

      Hi there! It seems to be an interesting project to take a look into. Not sure how the design of the visu is done but maybe reducing algo the amount of element in each visu page maybe the solution. Also changing the visu task and the mast task to avoid the 85% may help.

  • @rhinoslappaz3979
    @rhinoslappaz3979 Місяць тому

    Hi LeTomas On My operation terminal expert there is no cliparts folder in the buildtimedata folde. Where can I find this?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA Місяць тому

      Hi there! it seems that is has been move to : C:\Program Files\Schneider Electric\EcoStruxure Operator Terminal Expert 3.5\Buildtime\PropertyDefinitions\ScreenDesign\GraphicObjects\04-Cliparts BUt i have not test it.

  • @davidjoyoktavianusbancin7641
    @davidjoyoktavianusbancin7641 Місяць тому

    thank you for the videos brother, this is the most complete training i ever seen on youtube. i watched all your video btw. is it M series PLC using codesys as the based? look same with codesys 3.

    • @LeTomasAHUMADA
      @LeTomasAHUMADA 28 днів тому

      Hi there! Only Modicon M238, M241, M251, M258, M262 and PacDrive uses the software MachineExpert(SoMachine) that is based in codesys.