Innovation Plumbing Services LLC
Приєднався 26 жов 2011
1 800 678-0770
Locating a copper pipe under the concrete slab foundation.
Locating a copper pipe under the concrete slab foundation.
Переглядів: 95
Відео
Slab leak. Hot water manifold rebuild with re-routed pex pipe.
Переглядів 1035 місяців тому
Slab leak. Hot water manifold rebuild with re-routed pex pipe.
Installing a Moen Flo automatic water shut off device on an older home with Galvanized steel pipes.
Переглядів 1,5 тис.5 місяців тому
Installing a Moen Flo automatic water shut off device on an older home with Galvanized steel pipes.
Plumbers charge to much. Maybe, maybe not. Under the home repair.
Переглядів 616 місяців тому
Plumbers charge to much. Maybe, maybe not. Under the home repair.
Water pipe leak under the home. Making the repairs using Propress. Milwaukee M12
Переглядів 3648 місяців тому
Water pipe leak under the home. Making the repairs using Propress. Milwaukee M12
Andrew the journeyman working with Tony the apprentice. Typical under the house drain pipe repair.
Переглядів 4718 місяців тому
Andrew the journeyman working with Tony the apprentice. Typical under the house drain pipe repair.
2” cast iron drain pipe inspection using our new Milwaukee M18. Can you spot the holes in the pipe?
Переглядів 5110 місяців тому
2” cast iron drain pipe inspection using our new Milwaukee M18. Can you spot the holes in the pipe?
ABS Drain pipe inspection using our new Milwaukee M18 pipe line inspection camera
Переглядів 42410 місяців тому
ABS Drain pipe inspection using our new Milwaukee M18 pipe line inspection camera
M18 pipe line inspection camera unboxing.
Переглядів 10010 місяців тому
M18 pipe line inspection camera unboxing.
Tutorial on shark bite / push together fittings. Applications
Переглядів 3010 місяців тому
Tutorial on shark bite / push together fittings. Applications
Tutorial on connecting Propress fittings. Using Milwaukee press tool.
Переглядів 11 тис.10 місяців тому
Tutorial on connecting Propress fittings. Using Milwaukee press tool.
Tutorial on soldering a copper fitting.
Переглядів 5011 місяців тому
Tutorial on soldering a copper fitting.
Innovation Plumbing. Water leaking under the house, water pipe leaking in the wall above.
Переглядів 2211 місяців тому
Innovation Plumbing. Water leaking under the house, water pipe leaking in the wall above.
Gas Pipe installation. Dug by hand to avoid damaging utilities.
Переглядів 193 роки тому
Gas Pipe installation. Dug by hand to avoid damaging utilities.
What about when the 100 degree sun hits it straight on and throws off the water temp sensor??
amazon has a cutter for that
Not recommended for galvanized pipes. Call back city here. They need a new water main as well.
Wtf, lol
Bad joint?
There’s actually no joints under the slab. It’s soft copper with manifolds inside of the walls. It’s usually caused from expansion and contraction over time and the chlorine that the city’s puts into the water…
@@ainnovate88 Nevermind...
What brand leak detection equipment do you use? Looking to get some my self
Fisher M-scope Milwaukee cameras and locators
Fisher m scope listening device. Ridgid transmitter and Milwaukee locator.
Nice work, what was the bill for all that?
2600
@@Innovation_plumbing well, that was no small job
Water service
A 1 inch water main. The smallest city water main I've ever seen was at least 2 inch.
3/4 to a 4 port 1/2 manifold... pressure is going to stink for multi fixture use.
Y they build shit like this
Good question
u have no rizz
how old are you
🤣🤣🤣
I got the L Rizz😢
Through the attic?? You aren’t in Indiana are you??
California
Hot line dippy
That repair cost a fortune.
A lot of people would have trouble tracking that leak down, gotta pay for experience 🤷♂️
Anywhere from 2k to 5k
2600
I can replace a submersible well pump standing on my head. Only know that, becuase my well head is considerably below grade.
Hey, at least he’s a plumber that knows how to keep his pants pulled up so you don’t see any crack
Hmm... That fernco has a bit of angle in it. You don't use shear rings? Required in my area.
You have a very good eye. I didn’t think anyone would catch that. Normally I don’t use those in that application. Had some angle issues following the old line. Good catch. 😮
Good job
Where’s the shut off before the moen value ?
No shut off valve or PRV before the Moen Flo?
Nice. Digital geophones, or IF
How would one determine what line is the main supply once it disappears underground from the main at the street?
How many homeowners know where their main supply is other than the shutoff at the street?
Compared to 5 hours? Thats a drop in yhe bucket!
No winter
Could you also just use 2 ferncos? Aren't they allowed to be buried?
I test them all the way and then put the blue snap off kind in. Sometimes we have to run across the entire shower for customs and usually have to dodge a niche so it's just second nature to test every inch of the pipe you install.
Dog you gotta be the worst inspector ever brass and copper is hard to solder?
Have you had any weeping with M copper
Is it allowed to be outside without a cover ?
Hey what is the 90 at the shower head called
Dropear 90
Wing ell also.
Needs to be lower and instruct the homeowner to get roof insulated. Good work. It’s hard and hot up there. But most licensed guys are still putting water in slabs new construction residential. While commercial never put water in concrete. The residential guys will destroy me. They work with hvac guys that are stupid. Then the homeowner wants to save a $1000 by only insulating the ceiling.
QUESTION what model of jaws are you using?
Both of their PRVs are sideways. I’m sure you’ll be back out there soon
Getting mine installed tomorrow
I heard it takes 5 minutes……that’s a lot of water damage
18” of copper minimum before converting to pex
I use the viega 316 carbon steel to press onto galvy, works like a charm and its been years with no galvanic corrosion
The fun thing with Propress fittings is that it may take weeks or even months before the leaks become apparent.. If they are inside the walls or the ceiling, that's where the real fun begins. If you trust rubber gaskets that much , maybe you should plumb your house with garden hoses.You won't even have to buy the $500 tool... Think of the time and money you will save.
Listen not to call anybody uneducated or unexposed to the day-to-day with the material and the tool. I have pressed thousands of times. I have used Nibco, Mueller and Viega ranging all the way up from half to four inch. We put this s*** in 30 million homes with booster pumps. I hydrostatic my systems to 140 PSI after bleeding all of the f****** air out of everything making sure that all the volume controllers are open and that all heaters are looped. I used to hate this s*** as much as anybody thinking it was going to put the skill out of the trade but you have to adapt or you'll get buried. Make sure the O-rings are clean make sure the pipe is beveled push that c*** all the way on and squeeze it. If the failure rate was so high on this the insurance companies would outlaw it like polybutylene.
Short blade sawzaw?
I got so dizzy watching this man. Holy smokes
How much labor + parts?
Wow these guys are so efficient and professional!
Say you don’t work for the company without saying you work for them with your name lmao
Are you sure the first guy was really a plumber? Cuz I don't have any plumbers that wouldn't want to go overhead and save themselves so much trouble.
Depending on where this is I hope it was insulated once done
The PEX or copper?
What ever is In the nonconditioned space
How much for labor ?
Makes it worth not using.
Couldnt you tell there was a leak by seeing all the rotted wood?
How are you running the water heater to the ice box and still expect cold water?
This electronic leak detection? It will pin point the leak ? What’s the tool called
Did he tell you how that works?