Deanna Littlejohn
Deanna Littlejohn
  • 60
  • 169 003
CEC 2018 Full House Calculation 8 x 12 includes breaker and wire sizing
In this video, I use all of the 8-200 sub-rules to calculate the demand for a house. I also show you how to find the service conductor and breaker size using Tables 2, 4, 13 and 39. Please note that T-39 has been deleted in the CEC 2021 edition of the code. This means that you will just use Table 2 or Table 4 to find the conductor size. The conductor and breaker ampacities must be large enough to meet the calculated demand of the home. (But be careful in that the breaker ampacity can not be larger than the conductor ampacity)
Переглядів: 6 317

Відео

CEC 2018 House Calculations "Catch all" Rule 8-200 (1)(a)(vii)
Переглядів 3,1 тис.3 роки тому
Using the Canadian Electrical Code 2018, I explain how to use the "Catch All" rule to determine the demand factors for house service.
CEC 2018 House Calculations Electric Vehicle Chargers: Rule 8-200 (1)(a(vi)
Переглядів 3,4 тис.3 роки тому
Using the Canadian Electrical Code 2018, I show you examples of how to calculate the demand towards the main service of a house.
CEC 2018 House Calculations Tankless Water Heaters, Pools, Hot Tubs and Spas: Rule 8-200 (1)(a)(v)
Переглядів 1,6 тис.3 роки тому
Using the Canadian Electrical Code 2018, I explain the difference between a tankless hot water heater and a hot water tank. I also show you the calculations towards the main service of a house.
CEC 2018 House Calculations Electric Range: Rule 8-200 (1)(a)(iv)
Переглядів 2,6 тис.3 роки тому
In this video, I use the Canadian Electrical Code 2018 and explain how to calculate the demand for the electric range that you use towards finding the the main service for a house.
CEC 2018 House Calculations: Heating and Air Conditioning Rule 8-200 (1)(a)(iii)
Переглядів 2,7 тис.3 роки тому
Using the Canadian Electrical Code 2018, this video will describe how to calculate the demand factors that you will use, for heating and air conditioning loads, when determining the main service for a house.
CEC 2018 House Calculations Living Area and Basic loads: Rule 8-200 (1)(a)(i)(ii)
Переглядів 6 тис.3 роки тому
Using the Canadian Electrical Code 2018 this video show you how to calculate the living area and the basic load when determining the demand factors to use for calculating the main service of a house.
CEC 2018-Section 62: Wiring the baseboard heat in a one bedroom house
Переглядів 4 тис.3 роки тому
In this video, I use the 2018 Canadian Electrical Code and show you the circuitry for three baseboard heater circuits. Please see the previous videos to learn how to lay out and calculate the breaker and wire size.
CEC 2018 Section 62 Calculating the breaker and wire size for baseboard heat in a one bedroom house
Переглядів 4,8 тис.3 роки тому
in this video we will use Section 62 of the 2018 Canadian Electrical Code to calculate the breaker and conductor size for three baseboard heating circuits We use 20 amp double pole breakers and 14/2 AWG conductors. We are also assuming that all of the equipment is marked which allows us to use a temperature termination rating of 75 degrees Celsius.
CEC 2018 Section 62: Laying out the baseboard heat in a one bedroom house
Переглядів 1,2 тис.3 роки тому
This video describes how to choose the size of the baseboard heater for each room and where to locate the heater and the thermostat.
CEC 2018 Section 62 Amended Section
Переглядів 7333 роки тому
In this video I will outline the difference between a General Section and an Amended Section. The example I give explains why we do not apply rule 14-104 (2) to a Section 62 baseboard heating circuit calculation.
CEC 2018-Section 62: Baseboard Heat Calculations
Переглядів 4,4 тис.3 роки тому
In this video I will show you how to determine the minimum wire ampacity and breaker size for baseboard heating circuits. For these calculations, I follow the 2018 Canadian Electrical Code in Section 62 and use Table 2 and a 75 degree Temperature Termination Rating.
CEC 2018-Section 62: Hot Water Tank Calculations
Переглядів 2,5 тис.3 роки тому
In this video I show you how to calculate the minimum ampacity of your conductor and breaker for the 3000w, 4500w and 5500w Hot Water Tanks. These calculations are based on the 2018 Canadian Electrical Code, Table 2 and 75 degree Temperature Termination Ratings.
CEC 2018-Section 62: HWT and Baseboard Heat Rules
Переглядів 1,2 тис.3 роки тому
In this video, I explore and summarize the rules relating to Hot Water Tanks and Baseboard Heat, from Section 62 of Canadian Electrical Code 2018. In the next couple of videos, I will complete the calculations to determine the correct wire size and breaker size.
CEC 2018-Section 26: Kitchen Range and Dryer rules
Переглядів 3,6 тис.3 роки тому
Using the Canadian Electrical Code, I will summarize the correct wire, breaker and receptacle to install.
CEC 2018-Section 26: Kitchen Laying out and wiring a kitchen
Переглядів 31 тис.3 роки тому
CEC 2018-Section 26: Kitchen Laying out and wiring a kitchen
CEC 2018-Section 26: Rules for Kitchen receptacles
Переглядів 7 тис.3 роки тому
CEC 2018-Section 26: Rules for Kitchen receptacles
CEC 2018-Section 30: Wiring the lights, switches, smoke detectors and fan in a one bedroom house
Переглядів 1,9 тис.3 роки тому
CEC 2018-Section 30: Wiring the lights, switches, smoke detectors and fan in a one bedroom house
CEC 2018-Section 30: Laying out the lights, switches, smoke detectors and fan in a 1 bedroom house
Переглядів 1,4 тис.3 роки тому
CEC 2018-Section 30: Laying out the lights, switches, smoke detectors and fan in a 1 bedroom house
CEC 2018-Section 30: Wiring the lighting and smoke detectors for a 2 bedroom house
Переглядів 9623 роки тому
CEC 2018-Section 30: Wiring the lighting and smoke detectors for a 2 bedroom house
CEC 2018- Section 30: Laying out the lighting for a two bedroom house
Переглядів 8763 роки тому
CEC 2018- Section 30: Laying out the lighting for a two bedroom house
CEC 2018-Section 30: Rules for lighting
Переглядів 1,4 тис.3 роки тому
CEC 2018-Section 30: Rules for lighting
CEC 2018-Section 26: Wiring general purpose receptacles in a 2 bedroom house
Переглядів 6 тис.3 роки тому
CEC 2018-Section 26: Wiring general purpose receptacles in a 2 bedroom house
CEC 2018-Section 26-Laying out general purpose receptacles in a 2 bedroom house
Переглядів 2,8 тис.3 роки тому
CEC 2018-Section 26-Laying out general purpose receptacles in a 2 bedroom house
CEC 2018 -Section 26: Rules for laying out receptacles in a dwelling unit
Переглядів 1,9 тис.3 роки тому
CEC 2018 -Section 26: Rules for laying out receptacles in a dwelling unit
CEC 2018-Section 26: Rules for AFCI, GFCI and Tamper resistance receptacles
Переглядів 4,2 тис.3 роки тому
CEC 2018-Section 26: Rules for AFCI, GFCI and Tamper resistance receptacles
Transistor Saturation Calculation
Переглядів 2154 роки тому
Transistor Saturation Calculation
Transistor Intro and calculation
Переглядів 1874 роки тому
Transistor Intro and calculation
Zener Diode calculation#1
Переглядів 5294 роки тому
Zener Diode calculation#1
Zener Diode as a Voltage Regulator
Переглядів 2254 роки тому
Zener Diode as a Voltage Regulator