- 102
- 82 104
Power Fist Wang
Hong Kong
Приєднався 9 бер 2012
Amateur electronic enthusiasts, like to repair a variety of electronic equipment, A multimeter Fan
Troubleshooting and Repair of Fluke 17B Multimeter Resistance Testing Function
Troubleshooting and Repair of Fluke 17B Multimeter Resistance Testing Function
Переглядів: 470
Відео
Fluke 101 multimeter battery leakage repair
Переглядів 7077 місяців тому
Fluke 101 multimeter battery leakage repair
Victor 17 multimeter battery corrosion repair
Переглядів 6608 місяців тому
Victor 17 multimeter battery corrosion repair
repairing a Fluke 15B multimeter that was connected to the wrong power source
Переглядів 1,1 тис.8 місяців тому
repairing a Fluke 15B multimeter that was connected to the wrong power source
repairing a non-powering-on Fluke 15B multimeter
Переглядів 5748 місяців тому
repairing a non-powering-on Fluke 15B multimeter
Repairing Water-Damaged Fluke 15B+ Multimeter
Переглядів 5358 місяців тому
Repairing Water-Damaged Fluke 15B Multimeter
Repair a severely corroded Fluke 17B+ multimeter
Переглядів 1,1 тис.10 місяців тому
Repair a severely corroded Fluke 17B multimeter
Fix a water-damaged fluke 107 multimeter
Переглядів 56311 місяців тому
Fix a water-damaged fluke 107 multimeter
Fluke 15B+ Multimeter Battery Leak Repair
Переглядів 60111 місяців тому
Fluke 15B Multimeter Battery Leak Repair
Fixing a Water Damaged Fluke 303 Multimeter
Переглядів 43911 місяців тому
Fixing a Water Damaged Fluke 303 Multimeter
Repairing Two Fluke 179 Multimeters (Part 2)
Переглядів 2,8 тис.Рік тому
Repairing Two Fluke 179 Multimeters (Part 2)
Repairing Two Fluke 179 Multimeters (Part 1)
Переглядів 1,9 тис.Рік тому
In this video, we will be repairing two Fluke 179 multimeters. Stay tuned for the step-by-step process and troubleshooting techniques to fix these multimeters.
Repair of Battery Corrosion on Fluke115 Multimeter
Переглядів 1,2 тис.Рік тому
Repair of Battery Corrosion on Fluke115 Multimeter
Repairing a Fluke 15B Multimeter that won't turn on
Переглядів 857Рік тому
Repairing a Fluke 15B Multimeter that won't turn on
Repairing a Corroded Fluke 787 Multimeter
Переглядів 1,6 тис.Рік тому
Repairing a Corroded Fluke 787 Multimeter
Repairing a Water Damaged Non-functioning Fluke 107 Multimeter
Переглядів 638Рік тому
Repairing a Water Damaged Non-functioning Fluke 107 Multimeter
Repairing a Non-functional Fluke 17B+ Multimeter Purchased from Second-hand Market
Переглядів 735Рік тому
Repairing a Non-functional Fluke 17B Multimeter Purchased from Second-hand Market
Repair of three Fluke multimeters sent in by fans
Переглядів 965Рік тому
Repair of three Fluke multimeters sent in by fans
Repairing the Fluke 15B multimeter that repair fans had failed to self-repair
Переглядів 671Рік тому
Repairing the Fluke 15B multimeter that repair fans had failed to self-repair
Fluke 289 Multimeter Not Powering On - Repair
Переглядів 6 тис.Рік тому
Fluke 289 Multimeter Not Powering On - Repair
The extent of corrosion is astonishing! Fluke 15B+ multimeter repair
Переглядів 964Рік тому
The extent of corrosion is astonishing! Fluke 15B multimeter repair
Repair of Failed Fluke15B Multimeter during Circuit Board Relocation
Переглядів 867Рік тому
Repair of Failed Fluke15B Multimeter during Circuit Board Relocation
Repairing a Non-Powering Fluke 15B Multimeter
Переглядів 3,8 тис.Рік тому
Repairing a Non-Powering Fluke 15B Multimeter
Repairing a Water-Damaged Fluke 107 Multimeter That Won't Turn On
Переглядів 1,5 тис.Рік тому
Repairing a Water-Damaged Fluke 107 Multimeter That Won't Turn On
Repairing a Corroded Fluke 15B Multimeter Due to Leaky Batteries
Переглядів 674Рік тому
Repairing a Corroded Fluke 15B Multimeter Due to Leaky Batteries
Repairing a Fluke 179 Multimeter Burned Due to High Voltage Measurement Error
Переглядів 2,1 тис.Рік тому
Repairing a Fluke 179 Multimeter Burned Due to High Voltage Measurement Error
Repairing a Corroded Fluke 17B+ Multimeter
Переглядів 792Рік тому
Repairing a Corroded Fluke 17B Multimeter
Repairing a Fluke 17B+ Multimeter - Unable to Measure
Переглядів 1,2 тис.Рік тому
Repairing a Fluke 17B Multimeter - Unable to Measure
Hello Power Fist Wang, Do you happen to sell any t-shirts with your logo on them? Can you recommend any brands of soldering irons you like or heat guns, magnification camera's that you use to work/repair the pcb with on your channel. Let your fans know what you use or prefer to use, like flux, wire size for trace repairs and the like. Make it a video. Like your channel. Michael Tony Peters I am the same guys as below @TonyPeters-w3x. Thanks for the replies. I am going to attempt to repair a Fluke 289 display connector that was torn off by someone. Mostly pads and trace repairs, then parts install. see pic attached. C:\Users\stude\OneDrive\Pictures\PXL_20241004_005324588~2fluke 289 display connection broken. 1032024.jpg
Good day sir this IC you change is it programmable, and where can I buy IC FOR FKUKE179 thank you sir
Hi! My Fluke 117 shows F11- Err. Have I change it's M430F448 controller chip? And should it be pre-programmed?
hello! The chip is internally damaged, so you need to replace it with a new one. The chip contains a program, so you'll need to take one from another 117 motherboard, and it will require recalibration.
15和17系列看起來電路板都一樣,有沒有一種可能,接出15系列上未用到的按鍵接點,可以叫出17系列的功能,例如 Hz.
不需要可能,直接换一个17B的外壳和按钮,除了温度,缺少的功能都能用了😆
@ 請問17B max外殼按鈕買得到嗎?
@@BV7CW 去aliexpress看看
God day, I have fluke179, I hope you can help me. The fault is the same as the fluke 179 on your left side, sir how to test 6 pin resistor.
hello! Here is a list of corresponding resistance values between the pins of this resistor. Pin 1 is the pin farthest from the other pins. I hope this helps. 1 - 2 9.997M 5 - 3 1.113M 5 - 4 110.5K 5 - 6 10.21K
What is the value of the capacitor!?
3.3V 0.22F
您好。那麼您只是再次更換了LDO?您能告訴我這個LDO的名稱嗎?
Fluke 177 dice baff Q se Dano Es rescatable.
Can you please tell me why did you remove the Supercapacitor C145, does it work without it?... I think my Fluke 289 has a bad Super cap
@@avisponverdemx hello, i remove it because it was not working, the meter can not save the time data when i change the battery. and also you can remove it , the meter can work without it.
@@powerfist_wang Thanks for your answer... I have just removed the supercap haha, and now it works again!... the thing is I need to push the power button 3 or 4 times for it to power on... only a line appears each time.... but then it turn on.
Excellent service, congratulations🎉
Tell me, the probes on my fluke 179 do not ring, what could be the problem? no recording in call mode
Hello. Thank you for this video do you have a link for ordering the components please
How to name ic
❤
Ótimo vídeo. Estou com o fluke 287, ele liga da a primeira tela e depois apaga a tela e fica com o LED aceso. Você já deparou com este problema?
Congratulations on your work, a lesson
Tenho um deste modelo. Ele liga aparece a primeira tela de inicio e em seguida a tela apaga e fica com o botão power aceso. Tem conserto?
My 17B+ sem problem
Hello. Tell me, I have a Fluke 179, in diode test mode, at the output of the device 7.3 Volts. Does your device have this voltage too?
Yes, the test voltage for the diode of the FLUKE 179 is 7.2V. Are you concerned that it might burn out the circuit?
The user manual says 2 Volts! I have a Fluke 112, there is also a diode test voltage of 2 Volts. Thanks for answering, otherwise I wanted to repair the multimeter.
Hola buenos días excelente los videos yo tengo un fluke 179 donde sale batt en pantalla en todas las funciones ya cambie una batería nueva y persiste el problema estaría muy agradecido por su ayuda
Hello, your 179 motherboard battery holder might be corroded. Open it up and check it.
Tengo un fluke 179 con el mismo problema de batt me puedes ayudar estaría muy agradecido
Hi friend, where I can get IC
@@rakshithshetty3807 try ebay
Buenos días tengo un fluke 289 y cuando enciende la pantalla tiene un contraste alto y después de normaliza cuando está encendido pero siempre un poco alto el contrastes voy a configurar y no puedo aumentar contrastes bajo por q llegó a su tope
i have a fluke179 .My multimeter fell into the water. Because of this, it won't turn on. Can you fix that ?
Great job! Thanks
SIR i have one fluke179 can you fix that one plz help me
Hello, what kind of malfunction is your 179 experiencing?
I Think battery leaking is a common problem in Fluke Multimeter . My fluke 17b+ had this same problem ( battery leak) Unfortunately i found that very early so my multimeter didn't reach in a bad stage, MY ADVICE TO EVERY ONE :- Please check your Fluke multimer's Battery status ones in a month, Other wise you will face this problem
Teacher i have one fluke 179 its new one but was damaged on high voltage frequency now is paralised can it be saved?
Hello, what are the current symptoms of the malfunction?
We dont understand, talk in english
hello, I am practicing my English speaking skills, and all my future videos will be in English.
If you have any questions, please feel free to leave a comment under my videos, and I will reply to your questions in English.
hola muy buenos los videos yo tengo un fluke 179 sin luces el cual en pantalla me sale batt en todas las funciones ya cambie una batería nueva de 9vdc pero sigue con batt en todas las funciones puede ayudarme con esa falla gracias
Hello dear I from India please help me fluke rms115 eepr error show on display please give me any solution 😭😭
Hello! The U2 chip is damaged, and you need to replace it with a new one. The chip contains a program, so you need to remove it from a motherboard of the same model. After replacing the U2 chip, you will need to recalibrate your multimeter
Hello friend, I have a Fluke 17+B, I would like its buzz to be very low, can you suggest someone to rent somewhere where the beeping sound is louder?????
hello ! replacing the buzzer with a louder one might help a bit, the overall improvement will be limited. To achieve a significantly louder sound output, you'll need to implement a buzzer amplifier driver circuit. This circuit can be connected to the buzzer to boost its volume.
@@powerfist_wang Which amplifier do you suggest? If you had to change the bell for a louder one, what would it be? because I don't know what voltage this campaign works on
@@JCELLSMARTREPAIRTVS I'm sorry, but I think the buzzer sound is already loud enough, and I haven't made any modifications myself. However, I have found some online resources that you can refer to. ua-cam.com/video/5D8jxj9chBo/v-deo.html
ua-cam.com/video/LsLjJElffFU/v-deo.html
Hello friend, I have a Fluke 17+B, I would like its buzz to be very low, can you suggest someone to rent somewhere where the beeping sound is louder?????
Hello friend, I have a Fluke 17+B, I would like its buzz to be very low, can you suggest someone to rent somewhere where the beeping sound is louder?????
Hello friend, I have a Fluke 17+B, I would like its buzz to be very low, can you suggest someone to rent somewhere where the beeping sound is louder?????
Hello friend, I have a Fluke 17+B, I would like its buzz to be very low, can you suggest someone to rent somewhere where the beeping sound is louder?????
Hello friend, I have a Fluke 17+B, I would like its buzz to be very low, can you suggest someone to rent somewhere where the beeping sound is louder?????
Oh geez, this fumble mumble dude, good grief! 🙄
❤😂😂
❤❤❤❤❤
更換的主芯片是新的还是旧的?
从料板上拆的
can you give the part number of this controller and is it already programed? if there a link to order it ?
А какую фрезу используете? Не алмазную?
Thnks
Отлично!
Здравствуйте, а в чём может быть причина таких окислов?
Здравствуйте, щелочные батарейки текут и корродируют.
Do you know if it's possible to get the outer shell/case for this meter? (not the yellow one but the hole gray shell)
Hello, try aliexpress.com, search keywords: Fluke Front Housing
I have a fluke 189 ii. When I turned it on it has black stripes on the screen. After leaving it on for a few minutes the screen comes back. Any idea what can caused this? Great video by the way.
Hello, in this case, the slow startup of the built-in operating system could be a possibility. It is also possible that the ROM chip is nearing damage
Ho la de Honduras. Tegusigalpa tengo un fluke 177 año 2002 esta malo al ensenderlo aparese 177 y - - - batt .pregunto cual ic le cambio para pedirlo. Saludos cordiales ..sigo biendolo en UA-cam 😊
Hola, BATT indica que no tiene energía. ¿Reemplazó la batería y la probó?
Hola amigo quiero un tik de diagrama de alimentación de batería 🔋. Saludos cordiales.
Sounds like he's half asleep. Useless...
I'm sorry, my speaking speed is indeed very slow. I also realize this issue and will work on improving it in the future.