ACCOMODATION GANGWAY CABLE BREAK HOW TO AVOID???
ACCOMODATION GANGWAY CABLE BREAK HOW TO AVOID???
Переглядів: 77
Відео
CARGO HOLD FAN FAULT HOW TO FIXED? OVERLOAD THERMAL RELAYS , CONTACTOR, CB SIZE, INSULATION CHECKING
Переглядів 8914 днів тому
CARGO HOLD FAN FAULT HOW TO FIXED? OVERLOAD THERMAL RELAYS , CONTACTOR, CB SIZE, INSULATION CHECKING
SHAFT GENERATOR CHANGE OVER TO AUXILIARY POWER GENERATOR AT 60.2HZ, 86KW SWITCHING SEMI AUTO SYNCHRO
Переглядів 5314 днів тому
SHAFT GENERATOR CHANGE OVER TO AUXILIARY POWER GENERATOR AT 60.2HZ, 86KW SWITCHING SEMI AUTO SYNCHRO
STEERING GEAR HYDRAULIC LOCK ALARM TESTING, ETO ETR EDUCATIONAL VLOGS
Переглядів 8614 днів тому
STEERING GEAR HYDRAULIC LOCK ALARM TESTING, ETO ETR EDUCATIONAL VLOGS
MARINE AIRCONDITIONING SYSTEM, MANUAL OPENING OF ELECTRONIC EXPANSION VALVES, SIEMENS, ETO ETR
Переглядів 17014 днів тому
MARINE AIRCONDITIONING SYSTEM, MANUAL OPENING OF ELECTRONIC EXPANSION VALVES, SIEMENS, ETO ETR
EMERGENCY POWER GENERATOR TESTING USING MECHANICAL SPRINGLOADED STARTERS
Переглядів 1514 днів тому
EMERGENCY POWER GENERATOR TESTING USING MECHANICAL SPRINGLOADED STARTERS
ME ENGINE MOPA & MOPB CHANGE OVER FROM OPERATOR MODE TO CHIEF MODE & OPERATE AIR RUN TESTING MAN B&W
Переглядів 3314 днів тому
ME ENGINE MOPA & MOPB CHANGE OVER FROM OPERATOR MODE TO CHIEF MODE & OPERATE AIR RUN TESTING MAN B&W
REEFER CONTAINER SOCKETS WITH 450VOLTS, 32AMPERES HOW IT WORKS?
Переглядів 11121 день тому
REEFER CONTAINER SOCKETS WITH 450VOLTS, 32AMPERES HOW IT WORKS?
MARINE AIRCONDITIONING SYSTEM FAULT HOW TO FIXED?THERMOSTAT, SOLENOID VALVE, UNLOADER VALVES, TIMERS
Переглядів 27021 день тому
MARINE AIRCONDITIONING SYSTEM FAULT HOW TO FIXED?THERMOSTAT, SOLENOID VALVE, UNLOADER VALVES, TIMERS
WATER MIST SPRINKLER SYSTEM MISS ACTIVATIONS HOW TO AVOID? & SHIPS WISTLE FAILURE HOW TO FIXED?
Переглядів 152Місяць тому
WATER MIST SPRINKLER SYSTEM MISS ACTIVATIONS HOW TO AVOID? & SHIPS WISTLE FAILURE HOW TO FIXED?
LIGHT FIXTURES REPAIR & REPLACEMENT ON DECK.
Переглядів 92Місяць тому
LIGHT FIXTURES REPAIR & REPLACEMENT ON DECK.
ELECTRICAL JOBS ON DECK, NONE CONFORMITY, SUBJECT TO PORT STATE CONTROL ISSUE'S NEED TO RECTIFIED
Переглядів 118Місяць тому
ELECTRICAL JOBS ON DECK, NONE CONFORMITY, SUBJECT TO PORT STATE CONTROL ISSUE'S NEED TO RECTIFIED
POWER GENERATOR PARAMETER VALUES IN PARALLEL OPERATIONS
Переглядів 152Місяць тому
POWER GENERATOR PARAMETER VALUES IN PARALLEL OPERATIONS
BALLAST TREATMENT SYSTEM OPERATIONAL CHECKING, TECHROSS
Переглядів 132Місяць тому
BALLAST TREATMENT SYSTEM OPERATIONAL CHECKING, TECHROSS
ISPS SEARCH LIGHT REPAIRS, MOTORIZED NOT WORKING HOW TO FIXED?
Переглядів 167Місяць тому
ISPS SEARCH LIGHT REPAIRS, MOTORIZED NOT WORKING HOW TO FIXED?
ANCHOR & MOORING WINCH OPERATIONAL CHECK TESTING, SPEED 1,2,3 HOW TO TEST PROXIMITY SENSORS WITH PLC
Переглядів 157Місяць тому
ANCHOR & MOORING WINCH OPERATIONAL CHECK TESTING, SPEED 1,2,3 HOW TO TEST PROXIMITY SENSORS WITH PLC
CRANE FAILURE HOW TO FIXED? NO LUFFING OUT, NO JIB & BOOM UP, LIMIT SWITCH BY PASS TESTING, CHECKING
Переглядів 200Місяць тому
CRANE FAILURE HOW TO FIXED? NO LUFFING OUT, NO JIB & BOOM UP, LIMIT SWITCH BY PASS TESTING, CHECKING
POWER GENERATOR SPEED CONTROLLER FAULT HOW TO FIXED? OVER SPEED TRIP PREVENTIONS
Переглядів 308Місяць тому
POWER GENERATOR SPEED CONTROLLER FAULT HOW TO FIXED? OVER SPEED TRIP PREVENTIONS
WORKING ALOFT, ELECTRICAL JOBS ON DECK
Переглядів 71Місяць тому
WORKING ALOFT, ELECTRICAL JOBS ON DECK
BALLAST WATER TREATMENT FAULT HOW TO FIXED? ECU PRU NO CURRENT OUTPUT NOT ACTIVATED DURING BALLAST
Переглядів 210Місяць тому
BALLAST WATER TREATMENT FAULT HOW TO FIXED? ECU PRU NO CURRENT OUTPUT NOT ACTIVATED DURING BALLAST
CRANE AUTOMATION & CONTROL SYSTEMS ERROR 14 ENCODER FAULT HOW TO FIXED???
Переглядів 100Місяць тому
CRANE AUTOMATION & CONTROL SYSTEMS ERROR 14 ENCODER FAULT HOW TO FIXED???
JACKET COOLING PRE HEATER FAULT HOW TO FIXED? 4 STROKE COMMON RAIL CONTAINER SHIP ENGINE
Переглядів 145Місяць тому
JACKET COOLING PRE HEATER FAULT HOW TO FIXED? 4 STROKE COMMON RAIL CONTAINER SHIP ENGINE
POWER GENERATOR STARTING FAILURE HOW TO FIXED, V- TYPE ENGINE DRIVEN ALTERNATOR, CONTSHIP
Переглядів 135Місяць тому
POWER GENERATOR STARTING FAILURE HOW TO FIXED, V- TYPE ENGINE DRIVEN ALTERNATOR, CONTSHIP
SHAFT EARTHING DEVICE MONITOR FAULT HOW TO FIXED, 4 STROKE MAIN ENGINE CONTSHIP
Переглядів 177Місяць тому
SHAFT EARTHING DEVICE MONITOR FAULT HOW TO FIXED, 4 STROKE MAIN ENGINE CONTSHIP
FUEL LEAK SENSOR CHECKED & ALARM TESTING, 4 STROKE MAIN ENGINE MAN B&W CONTSHIP
Переглядів 87Місяць тому
FUEL LEAK SENSOR CHECKED & ALARM TESTING, 4 STROKE MAIN ENGINE MAN B&W CONTSHIP
SMOKE & HEAT DETECTOR FAULT HOW TO FIXED? ADDRESSABLE PCC PURE CAR & TRUCK VESSEL
Переглядів 66Місяць тому
SMOKE & HEAT DETECTOR FAULT HOW TO FIXED? ADDRESSABLE PCC PURE CAR & TRUCK VESSEL
Naka CPP barko nyu sir ?
Opo may CPP kami
Plz remove background music
Thanks. Please keep sharing it.👍💯
Ingat idol...........
Thank you so much for sharing your knowledge and experience. But please can you make your videos in English please?
I will try my best
Thanks. Please keep sharing it. 💯
Thank you so much for this instructive video. Please keep sharing it. 👍💯
Thanks. Can you add English subtitle please? We do not understand anything else.
Explain in English It’s will be ease to understand everyone
Thanks for sharing your knowledge and experience. Please keep sharing it.
Thank you so much for this instructive. But can you add English subtitle please?
Ano po posible problema pag hindi sumusunod auto frequency ,hindi ng response ung governor motor pg ngaadjust ng frequency kht imanual mode sa control, pero pg pinipihit s engine side governor motor sumusunod nmn.
Thank you man , just try to explain to us in English
Thanks for sharing your knowledge and experience. Please keep sharing it. 👍
Please make video in english
Idol kita Sir. God bless you
@@benzjang765 thank you mga sir's Godbless you po
i am jonas from brazil
hi my friend, good video. but before you make another video, first of all checks your multimeter
very valuable sir
Great job lecky 👍
Thanks 👍
Sir paanu po ba mag check ng PRU nag alarm fail po kc
You re doing a great job lecky. ❤
Sir ask ako position deviation alarm nmin sa amin ,ano dpat gawin sir ,salamat po
Very helpful video. Thank you
Good day Sir, your all videos are very knowledgeable. I request to you whenever you shooting the video please shoot in full screen and keep the camera steady. Thanks👍👍
Good day Sir, Can you make the one video on 1.Before changing UV lamps and the capacitors what precaution we have to take 2. How to renew the defective UV lamps 3. How to test it's resistance. 4. How to connect the UV lamps tester. Thanks for the your hard work and sharing the your knowledge. 👍👍
@@singhraju4000 please watch and You can learn
Sir meron po kaming na encounter na electical noise detected at Suprv30 ma alarm di namin mahanap hanap
Sir sana po wala ng background music para maintindihan yung sinasabi mo
Thank you so much for sharing this informative knowledge. It means a lot. Your explanation of how to test water ingress alarms was perfect. I am waiting for more videos.
Tutorial looks good, but music its not neccessary....I cant concetrate
Hello sir tanong ko lang po kung ano po trabaho ng Wiper sa bulk man b&w tulad sa inyong makina?
Sir how about boiler feed pump water high level
@@MichaelEspinosa-e1d water feed pump water level high is sometimes true sometimes false depending on your water level calibrations set point
Nice one Sir
Great work lecky❤
Good video again lecky. Salamat
idiot, only put a bridge. Problem is in emergency switchboard. Go to ESB and check problem.
Thenks ETO, welldone 👏👏👏👏👏👏👏👏👏👏
Thank you too
Hi buddy, l am Jonas from Brasil.. l have knowloge from MAN Electronic system .8 years in Mauá shipyard as commissinig.. Do have any information about Alphatronic 3000
Firstly, thanks for sharing your knowledge and experience. Please keep sharing troubleshootings videos. And can you make your videos English please. Because i do not know Filipino. Also our crew is Filipino. Salute 🖐️
very professional!
Good day sir, please upload the two videos. One videos in English and another one in Filipino. So that we can understand what is going on. Thanks.
Thank you so much for sharing your knowledge and experience. Please keep sharing these kind of videos.
Kabayan kailanga lang Ng reset
Thank you so much for this instructive video. Please keep sharing troubleshootings.
Thanks sir
Thank you too
Thanks you sir.. more videos pls specially trouble shootings.. God bless
Please upload electrical diagram reading videos sir
Please avoid background music
thanks elec, I appreciate your effort.
Please avoid background music
very important work I learned today thank you so much you are the best.