Full Load Capacity of KNOX PV 5600 4KW HYBRID INVERTER
This video is on the demand of my viewers. This video shows the full load capacity of KNOX PV5600 HYBRID INVERTER at peak time with all the load working. 1/2HP donkey pump, 9 fans, 1 exhaust fan, 3 led light. I have Jinko 585W bifacial 6 panels attached with it
Переглядів: 1 819
Відео
SHARING MECHANISM OF KNOX PV 5600 4KW OR ANY OTHER HYBRID INVERTER
Переглядів 2,9 тис.5 місяців тому
This video describes the sharing mechanism of knox pv 5600 4kw hybrid or any other hybrid inverter in form of charging and discharging. This video also tries to answer the misconception that if the invert shares the load with battery then it can fully discharge the battery. This video is evidence that it discharges the battery when there is torque load or output load is more than the solar gene...
HOW MANY PANELS CAN BE ATTACHED WITH KNOX PV 5600 4KW HYBRID INVERTER OR ANY OTHER SOLAR INVERTER
Переглядів 1,1 тис.5 місяців тому
In this video I have explained the technical data of inverter and the formula to calculate the number of panels that can be attached with any inverter
How to Identify the Firmware Version of KNOX PV5600 HYBRID INVERTER without any app
Переглядів 1,4 тис.5 місяців тому
This short video is a quick tutorial to identify the firmware of knox pv 5600 4kw hybrid inverter without any app.
CAN A SOLAR PANEL AND SOLAR INVERTER GENERATE ELECTRICITY IN CLOUDY OR RAINY WEATHER?
Переглядів 1,2 тис.5 місяців тому
This video addresses a very commonly asked question can a solar system generate electricity in rainy or cloudy weather. Let's find out in this video
HOW TO READ ON SCREEN PARAMETERS OF KNOX PV 5600 4KW HYBRID INVERTER OR ANY OTHER SOLAR INVERTER
Переглядів 11 тис.5 місяців тому
In this video I have explained the on screen parameters and different icons of knox pv 5600 Hybrid inverter. These paramerts are almost identical with every solar/hybrid inverter
How to register WATCHPOWER app to connect KNOX and other HYBRID inverters with wifi
Переглядів 1,3 тис.5 місяців тому
This video demonstrates the step by step process of registering the Watchpower app for knox pv 5600 and other hybrid inverters to use with WiFi
HOW TO CONNECT KNOX PV 5600 4KW HYBRID INVERTER AND OTHERS WITH WIFI AND VIEW PARAMETERS ONLINE
Переглядів 2 тис.5 місяців тому
This video is step by step guide to connect your knox inverter with WiFi and view and edit it's parameters online on the go with the help of Watchpower android/IOS app
Incorrect inverter setting causes AC /Heavy Load to Trip continuously
Переглядів 9 тис.6 місяців тому
In this video I have explained tha reason that causes the AC or heavy load to Trip again and again
HOW TO SAVE ANY SETTING IN KNOX HYBRID INVERTER.
Переглядів 6996 місяців тому
In this video I have demonstrated how to quickly save any setting in knox pv5600 or any other knox or hybrid inverter
KNOX PV 5600 4KW INVERTER SECOND/HEAVY/L2 LOAD ON OFF SETTING
Переглядів 9 тис.6 місяців тому
This video describes the procedure of 1. setting on off timing of heavy load 2. Cut off voltage to switch off heavy load on battery 3. Switching on Heavy load again after switching of on battery 4. Time duration to switch on/off heavy load 5. Time interval to cut off heavy load after power loss/load shedding 6. Time interval/voltage to switch on heavy load again
KNOX PV 5600 4KW INVERTER IMPORTANT SETTING FOR MAXIMUM SOLAR GENERATION
Переглядів 8 тис.6 місяців тому
This video is a brief tutorial of important setting of KNOX PV5600 INVERTER for maximum solar generation and running of loaf without WAPDA sharing
KNOX PV 5600 4KW HYBRID INVERTER FIRMWARE DOWNGRADE TO V56 DUE TO LOW SOLAR GENERATION BUG IN V84.00
Переглядів 6446 місяців тому
This vlog is regarding the firmware downgrade of KNOX PV 5600 4KW Hybrid Inverter due to low solar generation bug in version 84.00
KNOX PV 5600 Hybrid Inverter Firmware Upgrade to Version 84.00
Переглядів 1,4 тис.6 місяців тому
Firmware update for knox pv 5600 4kw hybrid inverter. Firmware can be obtained on email nabeelraza.geo@gmail.com
VERY CHEAP DIY SOLAR SYSTEM EARTHING IN PAKISTAN ONLY RS 5000 😱 NO NEED TO PAY HEFTY AMOUNT
Переглядів 3786 місяців тому
VERY CHEAP DIY SOLAR SYSTEM EARTHING IN PAKISTAN ONLY RS 5000 😱 NO NEED TO PAY HEFTY AMOUNT
سولر سسٹم کی انسٹالیشن خود ہی کر لی 😍 40 سے 50 ہزار کی بچت 💵
Переглядів 4,1 тис.6 місяців тому
سولر سسٹم کی انسٹالیشن خود ہی کر لی 😍 40 سے 50 ہزار کی بچت 💵
KNOX PV 5600 4KW HYBRID INVERTER RGB RING LIGHT SETTING|FIRST TIME ON YOUTUBE
Переглядів 6 тис.6 місяців тому
KNOX PV 5600 4KW HYBRID INVERTER RGB RING LIGHT SETTING|FIRST TIME ON UA-cam
Brand New KNOX PV 5600 4KW Hybrid Inverter low load generation
Переглядів 9 тис.6 місяців тому
Brand New KNOX PV 5600 4KW Hybrid Inverter low load generation
Solar Distribution Box connections. Do it yourself
Переглядів 1,4 тис.6 місяців тому
Solar Distribution Box connections. Do it yourself
Unboxing and user review of Wadfow Electric Spray Gun 450 watts
Переглядів 1,1 тис.8 місяців тому
Unboxing and user review of Wadfow Electric Spray Gun 450 watts
Restoration of Old Solid wood Corner Rack
Переглядів 698 місяців тому
Restoration of Old Solid wood Corner Rack
DIY Cabinet from PVC Sheet by DIYPakistan RWP
Переглядів 454Рік тому
DIY Cabinet from PVC Sheet by DIYPakistan RWP
Wadfow Quick Release Bar Clmap 24"/2 Feet in Pakistan
Переглядів 193Рік тому
Wadfow Quick Release Bar Clmap 24"/2 Feet in Pakistan
76th Independence Day Celebration at Shehnaz Sheikh Hockey Stadium Rawalpindi
Переглядів 211Рік тому
76th Independence Day Celebration at Shehnaz Sheikh Hockey Stadium Rawalpindi
سروس اسٹیشن پر پیسے برباد مت کریں. اپنی گاڑی اور بائیک گھر پر ہی سروس کریں #Hyundai #Suzuki#gr150
Переглядів 395Рік тому
سروس اسٹیشن پر پیسے برباد مت کریں. اپنی گاڑی اور بائیک گھر پر ہی سروس کریں #Hyundai #Suzuki#gr150
Hyundai Foam Lance/ Foam bottle for Hyundai Pressure Washer in Pakistan #Hyundai #Pressurewasher
Переглядів 1,4 тис.2 роки тому
Hyundai Foam Lance/ Foam bottle for Hyundai Pressure Washer in Pakistan #Hyundai #Pressurewasher
JDR Top Box 45 Liters DIY Installation on Suzuki GR 150 Without any Modification.
Переглядів 2,9 тис.2 роки тому
JDR Top Box 45 Liters DIY Installation on Suzuki GR 150 Without any Modification.
JDR Top Box 45 Liters Unboxing And Quick Review
Переглядів 4802 роки тому
JDR Top Box 45 Liters Unboxing And Quick Review
Hyundai Pressure Washer 105 bar unboxing and quick review in Pakistan
Переглядів 1,2 тис.2 роки тому
Hyundai Pressure Washer 105 bar unboxing and quick review in Pakistan
Unboxing and Quick review of Ingco 20V Lithium ion cordles Impact drill CIDLI200215
Переглядів 3,7 тис.2 роки тому
Unboxing and Quick review of Ingco 20V Lithium ion cordles Impact drill CIDLI200215
Es per load 2 v show hoty hain load nai show hota aisa kiun hai?
Assalamu alikum sir Mery pas knox 5600 with 8 panels 585 jinko hn with 2 batteries phonix 210 ugs. Jb mn battery settings mn No5 pe agm rkhta hun to rat ko 25v pe battery puhnchti h to ac2 load bnd nahi hota or jb USE pe rkhta hon to bnd hojata . Par phir din mn msla ye krti h k din m solar par b jb heavy load dalta hun to tb b yhi issue ata h trip hojati h heavy load please guide krdain kesy problem solve hogi. Mjhe sirf rat m ye settings chahiey k automatic ac2 load bnd hu din m nahi.
sir solarmax 8kw ka kaisy update karain
Dear I don't have any idea about solar max. May be someone else can help
Bhi main na Knox 6 KW PV 8000 hybrid inverter without battery lagaya ha aur is k sath Longi himo7 (610) watts k 8 panels aur 555 watts k 2 panels lagai han aur wapda sharing ha. Peak hours main solar 1500 watts bhi nahi de raha aur wapda k units bhi ziada consume ho rahe han. Load orient ka aik fridge aur kuch led bulbs han. Kum production ke kia wajah ha. Aur without battery aur wapda sharing k sath best setting bata den.
Dear 555 watt walay utar dein. As per rule apka inverter lowest generation pe fix hota hay. Two different panels mein sy lower generation walay k hisab sy
Sir Knox 4kw pv5600 6plates lage hain raat ko begair kise alarm inverter b on hota hy koi breaker b trip nhe hota but light khud he off ho jate hy r thore der baad khud he on ho jate hy kia masla ho skta hy Battries b 2 lge hain
Voltage protector device lagi hoey hay to uski waja sy ho sakta hay. Aj kal rat ko 255-260 v aa rahay hotay hein wapda k
@Chobkar g sir 2 volt protection lgy hain 1 for wapda sharing 2 for solar sy sy agy kitna load chal rha hy.
Kindly ye bta den koi masla to nahe ya koi setting to nahe change krny ke zrurat
@qammerjavaid7996 voltage meter or over voltage ki setting to thora increase Kar dein
@@Chobkar thank you
Bhai meray 2 Knox pv 8000 lagay howay hai. Alag alag os mei say 1 inverter grid feeding krta hai or dosra nahi. Dono mai se sirf 1 feeding krta hai. Wapda voltage 250 tak hota hai. Kindly reply
Doosray ki grid feeding of hogi
@ dono on hai
AoA, How are you? men gher men solar lagwa reha hun, 8KW ka, mene apnay electrician ke kehnay pe Knox 8KW IP65 purchase kia he, balkay us ke israar pe, mera irada GoodWe 8KW IP65 ka tha. But ab men confuse and preshan hun kyun ke mostly log keh rahe hen ke Knox is not a good brand or GoodWe best he 8KW IP65 Hybrid inverters ke liye. Knox ke problems ye bata rahe hen: 1. High temperature (germyon) men kaam nahi kerta, trip hu jata he. 2. Load sharing ki koi information nahi he is men, yani wapda se kitna le rahe he or Solar se kitna le reha he. 3. Dedicated App nahi he in ki, apni, or ju he wu nahayat fazool (GoodWe has its only dedicated mobile app) 4. Efficiency men GoodWe se kam he 5. WiFi Issues 6. Info Screen gets dim/malfunction after 6-8 momths. 7. Changeover issue (GoodWe has seemless change over from Solar/Wapda to Batteries etc) Dono ka difference 10,000 ka tha, but shaid mera electrician Konx ke settings men zyada expert he, or some other issue, un ne Knox ka purchase kya he. mera sawal ye he ke 1. Men Knox lagwa lon ya change kerwa lon 2. Chlanay men theek he? Changeover issue tu nahi kerta? 3. Support kesi he, after sale support? 4. App mutmain hen is inverter se ya app ko moqa milay tu isko change karen ge? 5. Dobara aap ko chance milen tu yehi inverter len ge ya koi aur? Sorry, sawal/comment lamba hu gya, per pese laga reha hun tu zara preshan bhi hon
Max power Suntonic pv 5000 ki settings k bary mn b video banain pls aur sham ya subha k time Jo bar bar beep deta solar ki wja us ko kaisy khtm kia jaiy
Dear mujhay aur kisi inverter ka idea nahi hay. Ye lenay sy pehlay research ki thee, bad mein bhe jab issue ay to internet pe kuch nahi mila to again research ki aur socha k community k sath share kar doon kisi ka bhala ho jay
@Chobkar thanks
Heavy loand and light load ki neutral agr common ho jaye to koi issue ha k nhi?? Q K ghr k db box ma bhe sare neutral common a rhi ha
Yes it's issue apki sari neutral common honay sy apka meter reverse light on karay ga aur meter on rakhay ga even when using solar
Sir ye battery aw wapda k bghair kitna load bardasht karta hai
Dear iski efficiency 95% hay so jitnay panels attach hein unka 95%tak
Sir yahi inverter mere pass ha raat ko .9 ampare wapda se musalsal le raha hota ha ye kese khatam ho jae
Change the setting to SBU instead of SUB. Watch my other video on the topic
@@Chobkar Sir yah inverter mere pass ha raat ko .9 ampare wapda se musalsal le raha hota ha ye kese khatam ho jae agr battery na ho to phir SBU kasay kam kry ga. ur 0.9 ampere kasay khatm ho ga without battery
@samraali7059 apkay inverter aur wapda meter ki earth common hogi Wo check Karen aur seperate karwa lein
@@Chobkar Wapda ki earth say murad us ki neutral to nhi? Wapda ki earth ha hi nhi ur inverter ik month phly lgaya h usi wqt earthing alag say ki ha.
@samraali7059 yes earth Matlab neutral
Asalamu Alaikum bhai mera invertor night me automatically wapda se bettry pr shift hota hai again and again.i am worries plz help
Bhai apnay volt meter ko check Karen aj kal Wanda sy over current aa raha hota hay to voltmeter wapda ko trip Kar deta hay aur inverter battery pe chala jata hay
اسلام علیکم اچھی علمی وڈیو ے آپ سے ایک سوال ے کہ یہ جو سیٹینگ 61/63/64 کی آپ نے بتائی ے یہ کب کام کرے گی جب out put source Sub پر ہو گا یا Sbu پر ہو گا ؟
SBU
Sir g temperature kha show hota he ye Bata plz
Is mein temperature sensor nahi hay
Heavy load battery pe bilkul bhe na chalay ki settings kia hogi??
High load ki setting huty ha 60 num setting
Setting save ni ho ri
Meny L1 heavy load pr rakho hy or L3 low load pr
Dear L1 is your normal load. L2 is heavy load. Inverter mein L1 cut karnay ka koi option nahi hay is leay heavy load ko L2 pe rakhein
سر یہ سیٹنگ sbu پر کام کرتی ھے
Brother battery gravity theek hai apki? Meri bhi same batteries same setup ke sath 2 weeks old batteries ki gravity nai maintain kar raha ye inverter. Balke batteries deep discharged hain. Sbu mode back to utility set on 24.0v charging oso. Bulk charging 29.2v
Back to battery 23.5 ya 22 Karen. Charing amp kitnay set keay hein ap nay 20 amp set Karen
@ brother 20 amps set kiya hain.. mein batteries se bikul backup nai le raha phir bhi batteries ki gravity red par aa rahi hai sab cells ki
@@muhammadasadullah3148 ap na pani add kia hai?
Brother isnt this inverter solarmax orion 4kw and others basically the same inverter from voltronic power? Shouldn’t this firmware work for others as well?
Dear I have not check solar max. If the inverter has same round display screen and it's removable then yes it may work on solar max as well
@ okay brother i have solarmax 4kw my issues are as follows… Pv dropping and batteries always showing discharging.. today tech ppl from company came and updated software decreasing the issues but still no complete resolution.. they say they will resolve every single issue. Lets see how it goes
battery continuous charging state or drainage state main nahiin rehni chahye, normally 2-3 din bad battery stable ho jati hay but still ager issue aye at night than contact service center.
Dear it's hybrid inverter. It works on sharing so battery is always in charging and discharging state
Brother why AC output line is blinking?
Its normal. Blinking means that its supplying output. If you turn off the side switch it will not blink.
bhai knox 6 kb frequnecy both up down hoti ha is k koi hal ha 15 amp sy 6 amp pa ajti h
It's firmware issue dear. Change the firmware
bhai frequncey up down hoti ha both .13amp sy 4 amp pa jti ha is ka koi hal ha.knox 6 kb . ❤
bhai frequncey up down hoti ha both .13amp sy 4 amp pa jti ha is ka koi hal ha.knox 6 kb . ❤
bhai frequncey up down hoti ha both .13amp sy 4 amp pa jti ha is ka koi hal ha.knox 6 kb .
bhai frequncey up down hoti ha both .13amp sy 4 amp pa jti ha is ka koi hal ha.knox 6 kb .
bhai frequncey up down hoti ha both .13amp sy 4 amp pa jti ha is ka koi hal ha.knox 6 kb .
bhai frequncey up down hoti ha both .13amp sy 4 amp pa jti ha is ka koi hal ha.knox 6 kb .
Sorry dear apka sawal nahi samjha
@Chobkar bhai .green meter laga ha .or revers load jo jata ha .us k ampire up down hoty ha
ap ka num mil sakta ha bhai
wapta ki tarf jo humri bijli jati ha .green meter laga ha. wo thk ni jati .kbi 14 ampire sy 4 ampire pa ajti ha
bta dy plz
bhai frequncey up down hoti ha .knox 6kb
Sir ya auto ni hota kya mtlb solar ka breaker on off karna parta hy jis tarha wapda ka breaker off kiya hy hy
Dear ye breaker is leay hay k wapda completely off ho jay otherwise in the presence of wapda solar pe shifting late hoti hay
580 waly bificial 6 sy zeyada mat lagaain 4 kw k sath
Sr mny b apny ghr mn lgwaya h bht issus hain kia apsy bt ho skti
Feel free to contact on nabeelraza.geo@gmail.com
Mere 4kw knox k sath 6 panels lage hain . Aj kal jan 2300 watts par jata hai tu again 1000watta par ajata hai. Stable nahi rehta. Kia reason ho sakti hai?
Dear bohat sari reasons ho sakti hein. Apka load unstable ho sakta hay. Agar battery attach hay to Wo charge ho jati hogi. Sun ki visibility proper nahi hogi. Apka question bohat he general hay aisay kuch bhe nahi bataya ja sakta.
@Chobkar Meri net metering hui hai. Us pr stable rehne chaye. Jan tk 2kw tak ho stable rehta hai 2.2kw par jaye tu fluctuations hti hain
@Zainou1 dear net Metering honay ya na honay sy farq nahi parta. Generation to solar angle, direction atmosphere pe depend karti hay
Thank you
Bro, upto my experience with pv5600... its display is full of errors... It shows battery discharging with 4A, but when u check it with ampere meter, it will be arung 1.4A... Similarly its shows solar input of 700W but on real time it will be more, I notice aroung 180W real time difference... Its displays wrong reading.
Dear 180-200w is the self consumption of inverter. In case of error you can update the firmware.
@Chobkar sir i update the firmware from service center. Unho ne khud b identity kiya k, generation load se zyada hona Chahiye, but after updation no change... Agr mera load 500w ho to solar se generation 350w krta hy, nd remaining from battery... Similarly agr load 1000W ho, to solar se generation 850 890w krta hy... Always generate less power than load...
@faisalkamal4219 then your firmware must have been updated to 80 or 84. Revert back to 56.72 or 60
@@Chobkar yes its firmware is 86 by default, and customer service center again restore the said firmware
@faisalkamal4219 that firmware has issue of low generation. Revert to 56.72
Sir apka number kea ha ph pa bt ho sakti h apsa??
Nabeelraza.geo@gmail.com
Kya is par 575w k 10 panels laga sakty hain ?
Yes
I suggest ka 9 sa zada na lagaya jya. As normally 8 panels pa ajkal 400V aa rha hota hain. Which is 50 V per panel. If we install 10 it will be 500 which is maximum Voltage so avoid it as during normal heat and sun shine after rain 52V tk aa jata hain which will exceed the limit. I hope sir agrees as well.
Assalamualaikum Sir kia ap mera aik masla ka hal bata dein ge ke mene same model lagwya ha raat ko jb inverter wapda pr shift hota ha to meter ki reverse or earth dono light on hojati ha mujhe dar ha ke kahi wapda meter tempring ka samjh kr mijhe fine na laga de kia mein relay ki madad se ise theek kr sakta hoon. Ap ka reply mere liye bohat ehmiyat rakhe ga shukria
Waslam dear. Ye issue tab ata hay jab apka installer install kartay hoey wapda aur solar ki earthing common Kar dy means wapda ka earth he use karay inverter mein wapda in wali jaga pe aur jo neutral inverter sy out hota hay uski jaga bhe wapda ka neutral he use karay. Apka neutral ko seperate karwa lein issue resolve ho jay ga.
I think yehi issue mere meter k sath b tha, q k m n kisi ko bijli di hui thi to phase inverter ka diya tha r neutral us k apne meter ki thi...jis ki wja se ye lights on rehti thi....phr usy neutral b m n apne meter wali di to thk hua....aeise krne se donu meters pe load chlta rha....phr hum n b setting krwai to problem solve ho gyi
Ye problem digital meter pe ati h, phly waly old pe ye msla n hota tha
On grid off grid and hybrid settings
Sorry apka sawal nahi samjha
how can we download latest firmware
It's is available online dear
salam boss mera swal ye knox 4k inverter hai wo without beatrey hai din ky time main error 15 ata hai din do sy 3 bar is ka solution barye kya kry?
Sir main password bhool gaya hn watchpower app ka .. kaise recover kia jae?? watchpower app pe reset ka option b nahi hai
AOA! Net metering ki knsi setting hai? Wo kese on krni hai after green meter installation.
Inverter body earth ac hota ha ya dc? Apne dc spd k sath connect kia ha
Aoa sir mere bhi Knox krypton pv 5600 ka Laga hoa hai woh na wapda sai current lete rahta tha or 1 sai 2 ampere girta rahtai to mainai aik din wapda ka breaker band krdia sham ko jab yeah wapda par shif hoa n to iski battery 0 thi yeah na jab wapda ka breaker band krdo to sir solar sai ghr ka load chlata hai battery charge nahi krta kindly bata dain uska thora sa
Dear ap wapda ka kaunsa breaker of kartay hein. Aik to Wo hota hay jo inverter mein input deta hay aur aik Wo jo wapda out hota hay
@@Chobkar sir woh breaker off krta hun jis sai input jati hain inverter mai jis sai wapda ka current inverter mai jata hai wapda ka main breaker
AoA
Mera inver Knox pv 5600 laga Howa hai 6 plates 585watt Per 800 watt say oper nai ja Raha
Kindly guide
The BMS sitting of powermax and inerex battery is very difficult can you please guide us
Aslam o Alekum bro mere pass b yahi model hai mene us ki 2nd load k cutoff voltage 24.8 rakhey hoe they khuch arsa sahi chala hai lekin ab 2nd load full battery discharge krne k bad off hota hai plz guide me
Check setting 60,61,62,63
inverter ki led screen kase Kar te ha kuch ke bat automatic off ho jae
It can not be turned off