PRACTICAL ELECTRICAL KNOWLEDGE
The First Philippine UA-cam Channel that covers the basics and most controversial topics about the Philippine electrical installations.
All are based on the Philippine Electrical Code (PEC) and relevant international standards unless otherwise specified.
Instagram: @eesnip
Facebook: Practical Electrical Knowledge
The First Philippine UA-cam Channel that covers the basics and most controversial topics about the Philippine electrical installations.
All are based on the Philippine Electrical Code (PEC) and relevant international standards unless otherwise specified.
Instagram: @eesnip
Facebook: Practical Electrical Knowledge
SERVICE ENTRANCE POLE LATERAL SERVICE EQUIPMENT METER POLE CONNECTION - EP 12.1 PART 2
Part 2... Isang malalim na diskusyon tungkol sa common sa atin na paggamit ng service entrance pole kung saan ikinakabit ang meter at service equipment.
🔗PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST
ua-cam.com/play/PLO4MWmSMQe6Z56GgD5IkGBzHMvW0u_Tqe.html
🔗 Part 1 here:
ua-cam.com/video/vunNWKiXKPM/v-deo.html&ab_channel=PRACTICALELECTRICAL
Chapters:
0:00 - Intro
1:02 - Meralco Requirements
2:23 - Service Protective Device vs Service Equipment
3:28 - Service Equipment on Pole
5:22 - Loadside Panelboard Grounding
6:45 - Pwede ba Hindi iGround?
7:50 - Branch Circuit Grounding
9:09 - Case 1 Meter and SE at Pole
9:45 - Case 2 Meter only at the Pole
11:45 - Service Entrance Conductors kasama ang Grounding Conductor?
13:17 - RCBO at the Service Equipment
🔗PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST
ua-cam.com/play/PLO4MWmSMQe6Z56GgD5IkGBzHMvW0u_Tqe.html
🔗 Part 1 here:
ua-cam.com/video/vunNWKiXKPM/v-deo.html&ab_channel=PRACTICALELECTRICAL
Chapters:
0:00 - Intro
1:02 - Meralco Requirements
2:23 - Service Protective Device vs Service Equipment
3:28 - Service Equipment on Pole
5:22 - Loadside Panelboard Grounding
6:45 - Pwede ba Hindi iGround?
7:50 - Branch Circuit Grounding
9:09 - Case 1 Meter and SE at Pole
9:45 - Case 2 Meter only at the Pole
11:45 - Service Entrance Conductors kasama ang Grounding Conductor?
13:17 - RCBO at the Service Equipment
Переглядів: 30 861
Відео
SERVICE ENTRANCE POLE LATERAL - SERVICE PROTECTIVE DEVICE METER POLE CONNECTION PART 1 - EP 12
Переглядів 73 тис.3 роки тому
Isang malalim na diskusyon tungkol sa common sa atin na paggamit ng service entrance pole kung saan ikinakabit ang meter at service protective device. Tatalakayin din dito ang tungkol sa kaibahan ng service protective device at service equipment at kung paano ang implementasyon nga mga ito. Kelan nga ba required ang mga ito? 🔗PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST ua-cam.c...
LINE TO GROUND TWO 2 POLE BREAKER JUMPER WIRE - HIWALAY ANG ILAW AT OUTLET SA ISANG BREAKER EP 11.1
Переглядів 52 тис.3 роки тому
Sa video na ito, paguusapan naten kung pasado nga ba sa Philippine Electrical Code ang talamak na paggamit ng 2 pole breaker sa line to ground o line to neutral systems para pag hiwalayin ang circuito ng ilaw at outlets! Malalaman din dito kung ano nga ba ang tamang gagawin at mga rekomendasyon at iba't ibang klase ng mga breakers na pwedeng gamitin para makatipid at the same time in line sa at...
LINE TO GROUND TWO 2 POLE BREAKER RCBO RCCB GFCI NEUTRAL AT GROUND BONDING TAMANG CONNECTION EP 11
Переглядів 37 тис.3 роки тому
Sa video na ito, pag uusapan naten paano nga ba iimplement ang tamang paggamit ng 2 pole breaker sa single phase 2 wire line to ground o line to neutral system. Tatalakayin din saan at paano ang tamang bonding ng grounded conductor (neutral) at equipment grounding conductor pag may 2 pole na breaker lalo na ang mga RCBO, RCCB o GFCI. PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST ...
LINE TO GROUND O LINE TO NEUTRAL CONNECTION METER CENTER GUTTER BOX GROUNDING SERVICE ENTRANCE EP 10
Переглядів 36 тис.3 роки тому
Sa video na ito, tatalakayin naten ang tungkol sa meter center na line to ground o line to neutral single phase 2 wire system. Full connection lahat ayon sa PEC at sa common practices. PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST 🔗 ua-cam.com/play/PLO4MWmSMQe6Z56GgD5IkGBzHMvW0u_Tqe.html
MERALCO SERVICE ENTRANCE HIGH RISE BUILDING ELECTRICAL MULTI METERING PER FLOOR METER CENTER EP 6.1
Переглядів 8 тис.3 роки тому
Isang mabilisang quick trial video lang ng ating multi metering per floor sa isang high rise building simula sa riser pole ni meralco papunta sa transformer vault tapos sa busduct riser hanggang sa makarating sa meter center per floor. PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST 🔗 ua-cam.com/play/PLO4MWmSMQe6Z56GgD5IkGBzHMvW0u_Tqe.html
LINE TO LINE METER BASE METER CENTER AYON SA PEC PAANO? SERVICE ENTRANCE GUTTER BOX GROUNDING
Переглядів 12 тис.3 роки тому
Sa video na to pag uusapan ang tungkol sa Line to Line Meter Center Multi Metering connection and wiring diagrams ayon sa Philippine Electrical Code (PEC) at NEC. Hango din rito ang mga best practices at common meter center standards ng mga DU like Meralco. PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST 🔗 ua-cam.com/play/PLO4MWmSMQe6Z56GgD5IkGBzHMvW0u_Tqe.html
LINE TO NEUTRAL AT GROUND - MULTI GROUNDED NEUTRAL SA DISTRIBUTION SYSTEM TRANSFORMER GROUNDING EP 8
Переглядів 19 тис.3 роки тому
Dito sa video na ito ay tatalakayin kung ano nga ba ang tunay na "multigrounded neutral" na ginagamit ng mga distribution utilities at rural coops sa Medium Voltage distribution systems sa bansa nateng Pilipinas. Parehas nga ba ito sa sinasabi nilang line to neutral at line to ground dito? At literal na ginawang ground ang neutral wire sa medium voltage??? PRACTICAL PHILIPPINE ELECTRICAL WEBINA...
LINE TO GROUND LINE TO NEUTRAL LINE TO LINE - PAANO ANG TAMANG WIRING NG METER BASE METRO - EP. 7
Переглядів 77 тис.3 роки тому
LINE TO GROUND LINE TO NEUTRAL LINE TO LINE - PAANO ANG TAMANG WIRING NG METER BASE METRO - EP. 7
METER BASE SA METER CENTER SERVICE ENTRANCE PEC BUSBAR CB GUTTER BOX MULTI METERING - EP. 6 MERALCO
Переглядів 81 тис.3 роки тому
METER BASE SA METER CENTER SERVICE ENTRANCE PEC BUSBAR CB GUTTER BOX MULTI METERING - EP. 6 MERALCO
LINE TO LINE CONNECTION SINGLE PHASE AYON SA PEC (MERALCO VECO SUPPLY) 110V PWEDE EP. 5
Переглядів 74 тис.3 роки тому
LINE TO LINE CONNECTION SINGLE PHASE AYON SA PEC (MERALCO VECO SUPPLY) 110V PWEDE EP. 5
LINE TO GROUND O LINE TO NEUTRAL SINGLE PHASE TAMANG CONNECTION PEC (PINOY TAGALOG) EP. 4 GROUNDING
Переглядів 282 тис.3 роки тому
LINE TO GROUND O LINE TO NEUTRAL SINGLE PHASE TAMANG CONNECTION PEC (PINOY TAGALOG) EP. 4 GROUNDING
GROUND WIRE SA SERVICE ENTRANCE AY KULAY WHITE O GREEN GROUNDING - EP. 3
Переглядів 45 тис.3 роки тому
GROUND WIRE SA SERVICE ENTRANCE AY KULAY WHITE O GREEN GROUNDING - EP. 3
NEUTRAL VS GROUND AYON SA PEC - TAMANG TERMINO (TAGALOG) - EP. 2
Переглядів 60 тис.3 роки тому
NEUTRAL VS GROUND AYON SA PEC - TAMANG TERMINO (TAGALOG) - EP. 2
LINE TO GROUND LINE TO NEUTRAL LINE TO LINE SINGLE PHASE HISTORY AT PAGKAKAIBA BASE SA PEC - EP. 1
Переглядів 222 тис.3 роки тому
LINE TO GROUND LINE TO NEUTRAL LINE TO LINE SINGLE PHASE HISTORY AT PAGKAKAIBA BASE SA PEC - EP. 1
Q&A: What happened here? (PVC Conduit Thermal Expansion)
Переглядів 1,8 тис.4 роки тому
Q&A: What happened here? (PVC Conduit Thermal Expansion)
Q&A: Transformer primary and secondary color coding required?
Переглядів 1,4 тис.4 роки тому
Q&A: Transformer primary and secondary color coding required?
Q&A: Why do we have 6 primary terminals on a pad mounted transformer?
Переглядів 3,7 тис.4 роки тому
Q&A: Why do we have 6 primary terminals on a pad mounted transformer?
Q&A: Is it required to disconnect the neutral or grounded conductor?
Переглядів 1,1 тис.4 роки тому
Q&A: Is it required to disconnect the neutral or grounded conductor?
Q&A: Is it okay to have 10 AWG wire for a 50A breaker for aircon units?
Переглядів 2,2 тис.4 роки тому
Q&A: Is it okay to have 10 AWG wire for a 50A breaker for aircon units?
Q&A: Grounding electrode conductor ferrous metallic raceway bonding
Переглядів 9434 роки тому
Q&A: Grounding electrode conductor ferrous metallic raceway bonding
Is it permitted to run equipment grounding conductors (EGC) outside raceways or cable assembly?
Переглядів 3 тис.4 роки тому
Is it permitted to run equipment grounding conductors (EGC) outside raceways or cable assembly?
What is the maximum busway / busduct support spacings?
Переглядів 1,3 тис.4 роки тому
What is the maximum busway / busduct support spacings?
Why do we need drip loops for service entrance?
Переглядів 1,5 тис.4 роки тому
Why do we need drip loops for service entrance?
Risers Guarding and Protection near Ground
Переглядів 1,2 тис.4 роки тому
Risers Guarding and Protection near Ground
Sir bakit dun sa isang video nyo po sabi nyo bawal ang grounded equipment conductor at gronunded conductor naka bonding sa Service equipment bakit jn po sa video nyo naka bonding po sa service equipment
HAPI NYU YIR SER, S BAHAY LINE TO GROUND S KAPITBAHAY LINE TO LINE PANO PO NANGYARI UN, ISANG POSTE LNG UNG SOURCE NMN. ALA NAMANG TRANSFORMER. PWEDE PO BNG MANGYARI UN? TNX
Mukhang di na kayo gumagawa ng video idol
Master pwedi bang Maka kuha ng 110v sa line to neutral ang supply?
Master ,tnx.
Master ,tnx. SA SA got
Master ,tnx. SA SA got
Master ,ask lng kng allowed ba Yung breaker branches na papuntang meter load side,pero my main panel 16branches, ang 16 branches na Yan idibiwal SA metro
NICE VIDEO SIR.. CLARIFY KO LANG BEFORE NG VAULT TRANSFORMER, SA PRIMARY SIDE..ANG VOLTAGE BA NIYA AY 13.2KV OR MEDIUM VOLTAGE?
Good morning po. Pwede po makisuyo ng contact number nyo? Thnx
Sir, pwede ba sub metering wla ng NEMA diritso na sa panel ng rooms
Idol kapag ba line to line same pa din ng current?or alternating pa din ba ang flow ng kuryente?
please provide us the controller wiring diagram
sir can you make for 3phase kwhr meter installation.
sir ask ko lang po sir bakit po sa probinsya wlang nema 3r system?
thank you sa information God bless po
Very detailed explanation, God bless sir. Paano po sa solar ground setup?
Galing ng paliwanag u idol ur d best
Sir gud a.m ask Klang kung Yung neutral bar ba na insulation or nkabond mismo sa NEMA 3r metal enclosure sir?salamat sa pagsagot po sir
Meron coop dito sa davao gumagamit ng green sa service entrance po
Good day po..maraming salamat po sa kaalaman na binabahagi mo palagi..god bless po...❤
Sir pwede po pa request kung paano mag install ng grounding sa loob ng panel board halimbawa sir subpanel at kung paano yung pag connect ng Neutral line sa grounding. thanks po
Mag ka iba talaga mga Pinoy Kasi marami kalokohan ginagawa kaya sa atin my Sarili pusti at para Hindi mag jumperan dun sa iba Bansa kahit wla pusti kahit whole ilagay nila Ang panil box tiyak Wala jajamper
Sir yung Green at White White Pwede ba siya pag samahin na idikit yung wire? Yung drawing mo kasi magkadikit yung white at green.
kaya pala sa america sir line to neutral kasi ang source nila is 120v lang.so ang isa hot at ang isang wire connected sa neutral kaya 120v lang.sa atin line to ground kasi ang source natin is 240v.ang neutral floated lang .ang line o hot ungrounded din ang isang line grounded kaya line to ground.😊
Pwede po rin ba ilagay ang neutral sa cb?
Boss paki lagayan ng green check yong mga tamang picture sample mo, boss, magulo paliwanag mo.
Maraming salamat master dami kong natutunan. May tanong ako sir bago lang kase ako sa electrical at gusto ko sanang lagyan ng service equipment iyong service entrance ng kuryente nmin wala kase cb direkta iyong wire pasok sa bahay namin pasok sa main panel or iyong tinatawag na service equipment customer load side. Ang tanong ko sir kapag naglagay ba ako ng service equipment malapit sa gate namin syempre as per sa natutunan ko dito sa video mo lalagyan ko ng MBJ at sa busbar eh magkasama iyong grounded wire which is iyong white at iyong equipment grounded wire which is yong green color. Tanong is kung koten 60 amp ang gagamitin ko eh ok lang po ba iyon kahit alam natin na walang ground fault protection iyong koten cb. Kase overload at short circuit protection lang sya.
👍👍👍
Ano po height nya meter to nema3r?😊
standard ba sa DU na hindi magbigay ng grounded service conductor sa service entrance? Line to Line yung connection. tapos L1 and L2 lang ang naka terminate sa service entrance
bakit sa lugar sa amin sa mindanao sir.ang binigay lang sa amin line to line lang.wla pong neutral line para sa grounding conductor.gagana pa din sir kahit magbaon ka lang ng ground sa lupa kahit hindi nkakabit sa neutral line ? magtri trip po ba ang breaker pag may ground fault?
Sir tanong ko po kung same lang po ba ng ampere na Circuit Breaker ang ilalagay sa Service Protection Device at Service Equipment?
Sir gud pm ask lang po what is the ampere rating protection at service equipment
So if Big deal ang kung before or after ilalagay ang bonding ng EG at GC, paano yung 1P+N na RCBO? since iisa lang din ang mag ttrip sa kanya which is yung L, pero yung N niya is concutive parin ?? So kung condutive parin yung N, hindi ba parang useless kung before or after yung bonding ng EG at GC dahil either way condutive parin yung N pole?
As youtube viewer po pero hindi po ako electrician kundi may konting alam lang natuto lang sa mga tropa ng konti, pati electronics may konti. May tanong ako sir, yon bang sabi mo na Grounded Service Conductor or yong Bare Wire ay physically may continuity or zero resistance between sa Grounding Electrode, Service Equipment Enclosure o circuit breaker panel at sa iba pang service equipment? sana mabasa mo tanong ko sir
Bakit daming rules and requirements? bakit di na lang iisa, for safety purposes dapat iisa lang ang sinasabi mapa meralco ka, o province or cooperative, dapat lahat may protective part na lahat malapit man o malayo. Para sa safety and maintenance purposes dapat lahat ng connection points from utility service drop down to owners service conductors, bldg. ckt. breakers dapat lahat meron ng protective devises before and after. Di yong kanya kanyang batas or requirements. Tutal lahat nman yan for human, animal and equipment safety. Dami pang nalalamang PEC provisions requirements.
Boss saan po ba mka bili ng gutter box
Sir line to line yung samin pano tamang wiring niyan according code
Sir magandang umaga tanong lang po yung supply set up ng meralco ganyan na po ba talaga na floating neutral? kasi galing probinsya kasi ako. follow up question yung mga branches po ba pwedeng 2 pole bolt on parang yung grounded conductor is idadaan ko pa sa 2 pole main breaker ng panel
Boss bakit d ka na nag uupload ng Bago? Lodi kita sa ganito. Sana bumalik ka sa pag share ng knowledge
husay...
Mali ba gumitin Ng natural gray sa grounded wire ..
Sir pwedi pa explain po nito *two of three sets of 3 wire feeders or two sets of 4 wire or 5 wire feeders shall be permitted to utilize a common neutral
sir tatanong lang sana..magtrip kaya yong ganyang set-up..isang pole sa light isang pole sa CO tas labas yong neutral? dba naka design yong koten na breaker or royu para sa 2pole? safe po ba?
Boss poweba mag lagay Ng ground sa panel baord
Sir pwd po vha mag request pwd gomawa kanang vedio kung pa,Ano malalaman ang busted nah 3phase transformer banking po.kahit Isa or dalawa ang busted sir Basta 3phase po siya kuh pa Ano po siya I,trouble shoot...salamat po Kasi yong single transformer tang galan lang siya nang load side Pag e, energize mo sasabog yong fuse Ganon porin vha sa 3phase salamat po.
gudam sir. pwede ba gumamit ng service drop wire from 1st house to 2nd house?
Ask lang if pwedeng magpalit Yung pwesto Ng bus bar gutter at breaker gutter
Paano pag sa bahay lang