tychlg
tychlg
  • 30
  • 9 569

Відео

C7.5 Audi S6 HVAC VCDS
Переглядів 4053 роки тому
C7.5 Audi S6 HVAC VCDS
C7.5 Audi S6 Climate control 6 to 8 ch recode to unlock all vents at the same time like a B5 A4/S4.
Переглядів 3793 роки тому
I missed this ability quite a bit in cold weather, nice to have warmth and flow everywhere. Actually saw the setting over a year ago when enabling Climate Styles for AC but it didn't click for me at the time what it was actually for. Another limitation removed, JD Powers surveys and the like have nothing to do with my selection. Also separately bumped auto fan speed one step up in adaptation, w...
Teamwork
Переглядів 75 років тому
Teamwork
Dead pass side turbo.
Переглядів 495 років тому
Dead pass side turbo.
F935 in about the worst conditions for it. 38F
Переглядів 1,2 тис.5 років тому
Shallow packy snow is right around the hardest thing for a single stage. Also bogged it in the deep area I'd been throwing snow. Ambient 38F
$14 heat/cool controller from Amazon on 240v
Переглядів 65 років тому
3.6F dead zone from factory, all adjustable.
After run pump whoa
Переглядів 75 років тому
After run pump whoa
Afternoon visitors
Переглядів 205 років тому
Mama deer and cute fawns get a little close to the house.
Bent bimba
Переглядів 15 років тому
Bent bimba
F935 model 50 blower 10" snowcover
Переглядів 545 років тому
F935 model 50 blower 10" snowcover
Grand Haven
Переглядів 115 років тому
Grand Haven
Tungsten sharpening with diamond lapidary wheels on delta bench grinder. Headphone warning.
Переглядів 1175 років тому
Diamond cutoff wheel is a new addition, seems ok, but a little slow compared to the grind wheel IMO. 100 grit Grinding wheel and 320 grit side disc have been in service for over a year in an amateur shop. Sharpened hundreds of tungsten electrodes with no sign of wear. Have a 1000 grit disc on opposite side if I want a very fine polish. www.amazon.com/gp/product/B0752XLB5P 100 grit wheel $50 www...
squirrel hopping through snow
Переглядів 1065 років тому
squirrel hopping through snow
Mohawk air lock mod
Переглядів 135 років тому
Mohawk air lock mod
Ir 2190 full forward
Переглядів 316 років тому
Ir 2190 full forward
Relay abuse with Keyence PJ-V90 safety curtain
Переглядів 1156 років тому
Relay abuse with Keyence PJ-V90 safety curtain
14ga load test 50a
Переглядів 648 років тому
14ga load test 50a
Dead seastar tilt helm unit
Переглядів 9078 років тому
Dead seastar tilt helm unit
Fluke 376 vs Mastech MS2115A - Idealarc 125 amps on dc scale, 1/8" 7018 3/8 plate
Переглядів 1,7 тис.8 років тому
Fluke 376 vs Mastech MS2115A - Idealarc 125 amps on dc scale, 1/8" 7018 3/8 plate
Idealarc 125a on dc scale, 1/8" 7018 3/8 plate
Переглядів 398 років тому
Idealarc 125a on dc scale, 1/8" 7018 3/8 plate
Breaking 75amp dc on 120v wall switch
Переглядів 418 років тому
Breaking 75amp dc on 120v wall switch
idealarc 250 load tests with and without PFC
Переглядів 3,6 тис.8 років тому
idealarc 250 load tests with and without PFC
MVI 1390
Переглядів 10411 років тому
MVI 1390
Sluice at Xuanwu lake
Переглядів 1411 років тому
Sluice at Xuanwu lake
Air hammer metal brake
Переглядів 27611 років тому
Air hammer metal brake
VID 00020-20101213-1232
Переглядів 1311 років тому
VID 00020-20101213-1232

КОМЕНТАРІ

  • @andrewkontoh6060
    @andrewkontoh6060 2 роки тому

    What caused that?

    • @tychlg
      @tychlg 2 роки тому

      Bad inner valve cover gasket around spark plug holes, part of full gasket kit. Replacement is doable in car without touching timing.

  • @digidandan
    @digidandan 2 роки тому

    Hi ! I made the modification in my a6, but although I do have 8 options in the climate control panel below - on the mmi main display I still have only 6 vent combinations available and it does not match with the real setup. Any thoughts what went wrong?

    • @tychlg
      @tychlg 2 роки тому

      MMI may need to sleep before it completely takes the new settings. Drove myself nuts at first going back and forth to make the video. Recall it being immediate when I first coded it though. If you ever do the park hold switch mod, coding for that just doesn't work at first, but if you shut down and lock the car, then come back an hour later it's fine.

    • @digidandan
      @digidandan 2 роки тому

      @@tychlg I did the coding few weeks ago, or I would rather say someone did it for me, since than it is still like mentioned unfortunately

    • @tychlg
      @tychlg 2 роки тому

      @@digidandan Odd, could be firmware level related, but don't have any further insight beyond what's in the video at this point.

  • @LextechLighting
    @LextechLighting 5 років тому

    I have rods of all sizes, but generally myself and most people run 3/32 or 1/8th rods for home use which tend to be ran around 85 (3/32) or 110 (1/8) and what we see here is that the amperage draw for these rods is a negative for users with PFC. You're only costing yourself money and pulling more amperage if you are running the typical home gamer rods if you use the PFC. For larger stuff the PFC can help you keep from popping a breaker in the surge absorption. Since the current stabilizes fairly quickly, I can't see a benefit for most users. When you get up above 1/8th rods if you have a weak breaker system it can definitely help.

    • @tychlg
      @tychlg 5 років тому

      The watts and thus costs drawn with and without pfc are pretty much the same, have to take into account the power factor shown on the meter. PF * A * V = W ; It's not pulling another 4300 watts at idle with PFC connected despite the apparent amps drawn. Other than at idle, PFC draws less current on this particular model. For home use it doesn't matter unless your supply is current limited, or if using a very long run of wire. As you mention, in this case PFC means 1/8" rod can be comfortably run on a 30a breaker. PFC NO PFC IDLE 24.75A 6.85A 50A 17A 20A 75A 16A 25A 100A 20A 38A 125A 26A 46A

  • @JustinCrediblename
    @JustinCrediblename 6 років тому

    Jesus. I left mine on for 20 hours accidentally the other day, with PFC. costs me more than air conditioning the house.

    • @tychlg
      @tychlg 6 років тому

      It's not as bad as it looks, the power factor at idle is about 0.07, which is horrible, but really brings the watts down. 238.3*24.71*.071= 418 watts 418/1000*20 = 8.36KW/h Assuming $0.15 a KW/h, that 20 hours of idle time cost $1.25. If it was actually a power factor of 1, it would have been $17.67 for the same 20 hours, ooof. I make no claims as to the accuracy of the meter, but the readings are in the ball park.

  • @davidlawrence8085
    @davidlawrence8085 7 років тому

    I like it, thank you for putting this video up. Guess my next clamp meter needs to be AC/DC clamp. Was just looking at meters at Home depot, their true RMS clamp meter is $20 more. L will have to go a bit further than Home Depot to get DC function Thanks again, Dave

    • @tychlg
      @tychlg 7 років тому

      Thank you! I've been happy with the Mastech meter, originally got it as a knockabout for the boat toolbox but it's become my go to meter, also have a more expensive Fluke 376, it doesn't come out of the case much any more except as a sanity check. The DC amp capability is very useful for troubleshooting charging and starting issues. www.amazon.com/gp/product/B00KFLSXAI One review says it doesn't have a zero button, but that's what the "REL" button is for.

  • @joeneal2422
    @joeneal2422 7 років тому

    Did you run two different Idealarc welders? or just disconnect the caps?

    • @tychlg
      @tychlg 7 років тому

      Same welder, had the cover off and connected/disconnected the cap wires for each amperage level.

    • @joeneal2422
      @joeneal2422 7 років тому

      great video thanks for posting

  • @williamflorez8777
    @williamflorez8777 7 років тому

    Dis culpame amigo la rotacion del m k 250 para cualquier direcion

    • @tychlg
      @tychlg 7 років тому

      Does it need a gear? ¿Necesita un engranaje? www.ebay.com/itm/Lincoln-Electric-OEM-S12637-Gear-for-Idealarc-250-Welding-Machine-28/401073784829