- 104
- 221 010
Antonio Adkins
United States
Приєднався 20 жов 2015
Just a random person who posts videos on UA-cam
I Microwaved my hand and this happened!
DO NOT REPEAT THIS VIDEO IF YOU ARE INEXPERIANCED WITH HIGH RF AND HIGH VOLTAGE DEVICES. I AM NO EXPERT IN GIVEING ADVICE BUT AM COMFTERABLE IN DEMONSTRATING THESE TYPES OF EXPERIMENTS YOU HAVE BEEN WARNED!
I have tried my best to explain how magnetrons work but im sure I screwed it up it so here are some links on how these things work. also feel free to comment on a better explanations of their function as well.
www.radartutorial.eu/08.transmitters/Magnetron.en.html
hyperphysics.phy-astr.gsu.edu/hbase/Waves/magnetron.html
I have tried my best to explain how magnetrons work but im sure I screwed it up it so here are some links on how these things work. also feel free to comment on a better explanations of their function as well.
www.radartutorial.eu/08.transmitters/Magnetron.en.html
hyperphysics.phy-astr.gsu.edu/hbase/Waves/magnetron.html
Переглядів: 179
Відео
Customer states he needs a new battery
Переглядів 352 роки тому
This is probably one of the worst batteries I've seen in a long time. absolutely amazed it didn't start a fire.
Dash light Tampering
Переглядів 312 роки тому
Be aware when purchasing a used vehicle even from a licensed dealer as scams like this can slip trough the cracks. I would advise on making sure that all of the indicator lights light up when powering on the vehicle. If your not sure on what type of indicator lights are on your instrument cluster you can always refer to the vehicles user manual and it will tell you all of the indicator lights t...
Major fire hazard
Переглядів 432 роки тому
This is why you NEED to clean out our dryer and dryer exhaust vent.
Intense CG Lightning (Deep bass)
Переглядів 1412 роки тому
Recorded this 07/05/22 at around 9:45PM to 10:05PM EDT. We had a Squall line of storms move trough upstate SC that evening with some imbedded severe thunderstorms. At first the storms where slow-moving and barely going any where at all but they eventuality got to my area. I did stay outside for a few but nothing impressive was taking place so I went back inside and about 15 minuets later I hear...
A Strong storm #3
Переглядів 332 роки тому
Another strong storm I managed to record. unfortunately for this one I forgot to adjust my camera settings to 4k instead of 1080p so hopefully the quality isn't total crap. This storm formed along a cold frontal boundary on 6/3/22 at around 11Am and moved trough my area at around 3Pm. I think the first warnings on this storm started around 1:30pm for 60Mph winds and quarter sized hail. As the s...
Fake 800 watt amp mixer
Переглядів 192 роки тому
Probably one of the most grossly overrated audio amps out there.
Failed Buss fuse and light
Переглядів 142 роки тому
This Video is to demonstrate what can happen to improperly rated or cheap fuses. In the video I show a fuse that appears to be melted due to not blowing as it should. I was using the fuses on the output of my home made linear power supply which can output up to about 100Amps at 12v DC, although I could have made it a single output I had it branch off into 2 individual channels with a maximum of...
Sun Rise Hyperlapse
Переглядів 202 роки тому
Recorded this on 05/31/22 Started around 5:25AM (EDT) and ended around 6:40AM (EDT) I recorded this with my S22 Ultra and took about 1 Hour and 6 Min to record.
A Strong Storm #2
Переглядів 262 роки тому
Recorded this on 05/21/22 around 2pm. At around 1PM a big cluster of isolated thunderstorms had merged together and formed a one big massive storm with an additional squall line on the east side of it. The storm was moving from west to east but was developing from south east to north east moving at around 20 MPH. on the east side it was rated severe for Quarter sized hail and 60 MPH winds but w...
Failed 2KW APC Rack Mount UPS Teardown PT3
Переглядів 772 роки тому
Failed 2KW APC Rack Mount UPS Teardown PT3
Failed 2KW APC Rack Mount UPS Teardown PT2
Переглядів 1052 роки тому
Failed 2KW APC Rack Mount UPS Teardown PT2
I had a malfunctioning. Microwave at work. I didnt notice it for weeks until i had a red heat rash on the back of my hand. It's similar to sticking your hand inside of a regular oven. You just cook your hand.
What is the final stabilized pressure is? Thank you.
When you replace the belt, be sure you use a fractional horsepower application belt. Using a standard Automotive V belt will overwork the motor.
What did you use to protect your camera from the microwaves? I've heard/seen other content creators use mesh screens or tin foil. It sounds like you've also used something to prevent the microphone from picking up the interference from the waves too.
Nothing. The camera was placed on a tripod at a distance so that the microwaves couldn't reach it to cause issues , as well as the interference with the mic.
I want to try this so badly one day. There is only one problem though, I live in an apartment full of electronics surrounding me like my gaming pc and other test equipments. I could however do it in my tiny closet located near the hallway. Since the rest of the room has concrete walls, the only thing left would be to seal of the closet's door with tin foil lol. The only thing I would worry about then is the wifi sitting on the hat shelf ín the hallway. I've found a lot of microwaves in my apartments recycling room that were thrown out due to burn spots on the waveguide, but I guess they would still work without them since none of them had any faults.
If the system is flat, meaning zero freon, put nitrogen 100 psi and find the leak. Fix leak. Then vacuum the system and charge it with (134a) in this case. Before transferring 134a, purge air from your automotive contraption line and then charge your system. For Charging, your compressor should be running. Not sure if these automobile charging hose with gauges are accurate. In a properly charged system, your discharge line temperature should be 20 degrees F higher than the ambient temperature.
Servicing a system with a leak thats gone flat has air in the loop. Adding refrigerant before repairing the leak and or pulling it into a vacuum is not recommended. Air = moisture which will eventually cause acid equalling in a compressor burnout.
I’ve been looking for a video like this as I had an ac like this that would run the fan continuously, which I thought was annoying. However, I found another problem with ACs that have their fans run continuously. A hygrometer (part of a digital temperature/humidity display) led me to this discovery which for the longest time puzzled me. While the compressor was running and the room was getting colder, the humidity would decrease. I knew that lower temperature air can hold less water vapor than warmer temps that a decrease in relative humidity meant that the unit was pulling a lot of moisture out of the air. However, as soon as the compressor cut off, the humidity spiked immediately, sometimes by as much as 20%. It took me a while to figure out what was going on, but what was happening is the condensation that had collected on the evaporator coils was getting reevaporated and blown back into the room. If the fan shut down when the compressor stopped it would have had time to drip to the outside. While it is true you waste a tiny bit of (sensible) cooling by not allowing the fan to at least run a few minutes at the end of the compressor cycle. (Also, you waste a little bit of sensible cooling as the reevaporation of this condensate essentially acts like a swamp cooler) it’s doing this at the expense of latent cooling (aka dehumidification). Having your room’s humidity at 45% instead of 65% allows you to set the thermostat a few degrees higher and still be (even more) comfortable. The alternative is also running a dehumidifier but in addition to the extra power usage, a dehumidifier swaps out latent heat for sensible heat, which then means you have to run your ac more…so even more electricity is used. By the way, instead of doing all this I just used a smart plug controlled by a temperature sensor. Also, I haven’t had any issues with it freezing up.
Day-Woo is how you say it.
Only took 15 months to wear out the rubber bushing. Most ppl will toss this dishwasher in the landfill rather than pay $400+ to repairman. (250 motor 150 labor) What a piece of crap. They know it'll last just long enough to get out of warranty. I used to like Whirlpool.
With a samsung what us happening whe the return line freeze up
can you tell me if there is a way to test the motor with my multimeter? Should there be continuity? Should there be a resistance? Thanks in advance. I didn't realize there was more to this motor with all the electronics you showed. My motor is slightly different but I'm sure it has that board now that it could be broke. I have it removed and would like to run the dishwasher to see if the plug gets power. It's completely unhooked from the plumbing though. Any reason you could think of why I couldn't try to run a cycle without the water supply hooked up? Thanks in advacne.
Dear friend thanks for your videos, I need to ask something, because I'm not too much prepared about the argument, I discovered a gas leak on a little refrigerant circuit I used as air conditioner... gas is propane R290, how I can charge it? Vacuum pump is needed right?
@Carlos4998 depends on the fittings used on the R290 tank. Unfortunately, I haven't messed with R290, so I'm not sure how to service a system that uses that refrigerant.
@@antonioadkins5104 I see... but I read that the valve you used in the video is also used for R290 systems
My Daewoo refrigerator says to use R-600 refrigerant. Can I use R-135 instead?
no
I do not think this fan is an attic fan. I believe it is just a normal whole house window fan. Some people put these in a regular window.
You are showing us the gauge but not explaining what we are seeing.
NEBO's only flashlight that focuses well is the 2,000 lumen Slydeking. That will do q nice tight beam. The 3,000, 5,000, 6,000, and the 12k are all lousy at focusing, and i have each of them. They're flood lights, not throw lights.
I have the same problem 😂but a push mower and the muffler valve blew to bits and now it’s just flames when it runs and when you shut it off it backfires and it’s so loud I’m going to scrap it
Yeah, that looks like it was made by Litton Industries for Whirlpool. Whirlpool didn't make a microwave for years as they didn't believe it would make money. Instead they distributed Litton's, and later were sued by Litton for cloning the design and introducing their own copy. I have the 1980 version which was actually made by Whirlpool and it is nowhere near as cool as yours.
You are my today hero :D Thank you !
134 has to be put in as a liquid. It’s a blended refrigerant, and you have to purge the air out the lines. Now you’ve made your own blend and contaminated the sytem.
Charging with R-134a can be done either as a vapor or a liquid, it is not a blend it is a pure refrigerant
I visited there in 2006
Why blow up perfectly good engine plus those are obsolete. That’s an engine they should make again but they don’t because it’s not fuel efficient that would be a good workhorse for somebody for many years if it’s taken care of
What is you gauge peeasure of unit how much it
Excellent. I took the motor apart, the bearings on both ends were worn to oval shape for my 5 years old Whirlpools dishwasher, acutally it is only 4 years old because the dishes was not cleaned, not after 2 to 3 wash cycles since the 4th years. The appliance is functional after I bought replacement because I took the dishwasher out examine every part for 3 weeks, not till I saw this video. Will put ball bearing on the broken motor as spare. The manufacturer should have specified a ball bearing motor in the design.
Does anyone know why my pressure gauge is reading 70 psi when I open up the piercing valve to get an initial read? Definitely not showing up as negative pressure. I’m 99% positive I’m installed on the suction line.
Well done forensic analysis. There are so many videos of guys replacing those pathetic shaded pole recirc pumps I'm amazed there isn't a class action lawsuit. Wouldn't be surprised if there were 10s of thousands (if not 100s of thousands) of those installed. You couldn't give me one of those dishwashers.
My 2008 Frigidaire DW just now (April '24) needed its very first repair. An under 10 dollar recirc pump start capacitor. I keep my reliable old appliances & do all my own repairs.
He sucks he shouldn’t be doing this of work
Your evaporator will ice up if the fan stops running. It’s made to draw in warm room air to defrost itself.
Thanks soooo much... I was pulling my hair out lol
580-600 rpm
You forgot to show one of the fans
Nice try but that will NOT check a breaker points magneto coil. You are inducing power directly into the core, which then induces power into the secondary, making the spark.
I want to see how small the beam can be, because the smaller the beam the longer the distance it travels
Doesn't focus very well. It won't shoot never far. It's a flood beam not a throw beam.
I am was having this problem with my Kenmore. There are new Upgrade Bushings available on a popular auction site. Easy $10 repair.
Lets clear up some incorrection assumptions and conclusions. The oblong wear pattern in the bushings is caused by the choice to use a two pole stator, which causes the rotor to consistently exert force against the bushings in the same elliptical pattern. A three pole stator would solve this problem by balancing the forces evenly thus causing circular wear pattern in the bushings. The rotor becomes unable to start spinning because of the elliptical wear allowing it to tilt inside the housing, coupled with the inability to rotate freely once tilted. If the bushings were simply worn evenly in a circular wear pattern, this motor should have no problem spinning up that rotor even when there is tilt of the rotor because it would be allowed to continue rotation without impediment from the top or bottom bushing. Secondly, the o-ring on the top bushing serves only to center the bushing in the cavity. This rotor (and the bushings) are designed to run fully submerged in water. Thus any solution involving ball bearings needs to be robust to full submersion (PVDF housings with glass or 316 stainless balls).
F!
funny
Есть заправочный патрубок , только с ним и надо работать . Его можно пережать ниже проколки и запоять . Глупо лезть в нормальный трубопрвод и делать в нем дыры . ПОНИМАШ .
hi, is the fridge still working?
Yep still working good
U knwo u can just change the antenna That copper looking metal it burned
Nicee fan collections
How do you know how much freon to put in it and is it okay to start charging with the compressor turned off like that my compressor is completely empty I thought you had to start the compressor first before charging it with the freon
how do you expel the air that is in the circuit?
in order to completely remove any air that may be in the system is to use a vacuum pump.
Much blushing
The telescopic antenna is only for FM.
Where do you put the pircing valve between the 3 pipes
On the suction side or low pressure side.
That was exactly what I was looking for. Not only will this save my current ac but probably another one that I have that has a bad control board
The EPA will fine you $10000 for every instance of recharging without repairing the leak first. Also they will fine you if you are not properly certified for refrigerant recovery and evacuation. This is only due to appliance manufacturers getting together and lobbying the EPA to do this. They don't care about automotive unless you are a shop.