- 542
- 520 127
VIAVI Product Training Videos
United States
Приєднався 26 вер 2018
How to Perform Bidirectional OTDR Testing with FiberCompletePRO
Introducing FiberComplete PRO - the smarter and faster way to perform bi-directional OTDR testing.
What is FiberComplete PRO?
Put simply, FiberComplete PRO is a complete suite of fully automated fiber testing capabilities designed to streamline the construction and qualification of any type of fiber optic network.
The result? Fiber acceptance testing done right first time with one fiber connection and a single button press - smarter, faster, and easier than ever before!
Watch this video to learn step-by-step how to use FiberComplete PRO on your VIAVI OTDR for efficient bidirectional OTDR testing and maximum network reliability.
Learn more about bidirectional testing on the VIAVI Perspectives blog
blog.viavisolutions.com/2023/02/06/why-perform-bi-dir-fiber-testing/
Learn more about the FiberComplete PRO product
www.viavisolutions.com/en-us/products/fibercomplete-pro-applications-bi-directional-fiber-testing
For more information, please visit: www.viavisolutions.com
--
Contact a Sales Expert
viavisolutions.link/contact-sales
Request a Demo
viavisolutions.link/demo
Request a Quote
viavisolutions.link/quote
FOLLOW US
Facebook: viavisolutions
Instagram: viavifiber
LinkedIn: www.linkedin.com/company/viavi-solutions
Twitter: viavisolutions
UA-cam: ua-cam.com/users/viavisolutions
What is FiberComplete PRO?
Put simply, FiberComplete PRO is a complete suite of fully automated fiber testing capabilities designed to streamline the construction and qualification of any type of fiber optic network.
The result? Fiber acceptance testing done right first time with one fiber connection and a single button press - smarter, faster, and easier than ever before!
Watch this video to learn step-by-step how to use FiberComplete PRO on your VIAVI OTDR for efficient bidirectional OTDR testing and maximum network reliability.
Learn more about bidirectional testing on the VIAVI Perspectives blog
blog.viavisolutions.com/2023/02/06/why-perform-bi-dir-fiber-testing/
Learn more about the FiberComplete PRO product
www.viavisolutions.com/en-us/products/fibercomplete-pro-applications-bi-directional-fiber-testing
For more information, please visit: www.viavisolutions.com
--
Contact a Sales Expert
viavisolutions.link/contact-sales
Request a Demo
viavisolutions.link/demo
Request a Quote
viavisolutions.link/quote
FOLLOW US
Facebook: viavisolutions
Instagram: viavifiber
LinkedIn: www.linkedin.com/company/viavi-solutions
Twitter: viavisolutions
UA-cam: ua-cam.com/users/viavisolutions
Переглядів: 3 413
Відео
VIAVI CleanBlastPRO: Refilling Solvent - Auto Method
Переглядів 141Рік тому
The CleanBlastPRO from VIAVI Solutions is a fiber optic end-face cleaning system that provides an automated cleaning process to ensure clean fiber connector end-faces at the press of a button. Ideal for fiber connectivity manufacturers, the CleanBlastPRO is equipped with a refillable internal solvent tank, intuitive LCD interface, and a handset that supports a comprehensive selection or precisi...
VIAVI CleanBlastPRO: Installing Cleaning Tips
Переглядів 174Рік тому
The CleanBlastPRO from VIAVI Solutions is a fiber optic end-face cleaning system that provides an automated cleaning process to ensure clean fiber connector end-faces at the press of a button. Ideal for fiber connectivity manufacturers, the CleanBlastPRO is equipped with a refillable internal solvent tank, intuitive LCD interface, and a handset that supports a comprehensive selection or precisi...
VIAVI CleanBlastPRO: Product Overview & Controls
Переглядів 86Рік тому
The CleanBlastPRO from VIAVI Solutions is a fiber optic end-face cleaning system that provides an automated cleaning process to ensure clean fiber connector end-faces at the press of a button. Ideal for fiber connectivity manufacturers, the CleanBlastPRO is equipped with a refillable internal solvent tank, intuitive LCD interface, and a handset that supports a comprehensive selection or precisi...
VIAVI CleanBlastPRO: Cleaning Simplex Fiber Connectors
Переглядів 394Рік тому
The CleanBlastPRO from VIAVI Solutions is a fiber optic end-face cleaning system that provides an automated cleaning process to ensure clean fiber connector end-faces at the press of a button. Ideal for fiber connectivity manufacturers, the CleanBlastPRO is equipped with a refillable internal solvent tank, intuitive LCD interface, and a handset that supports a comprehensive selection or precisi...
VIAVI CleanBlastPRO: Refilling Solvent - Manual Method
Переглядів 117Рік тому
The CleanBlastPRO from VIAVI Solutions is a fiber optic end-face cleaning system that provides an automated cleaning process to ensure clean fiber connector end-faces at the press of a button. Ideal for fiber connectivity manufacturers, the CleanBlastPRO is equipped with a refillable internal solvent tank, intuitive LCD interface, and a handset that supports a comprehensive selection or precisi...
VIAVI CleanBlastPRO: Menu Navigation
Переглядів 46Рік тому
The CleanBlastPRO from VIAVI Solutions is a fiber optic end-face cleaning system that provides an automated cleaning process to ensure clean fiber connector end-faces at the press of a button. Ideal for fiber connectivity manufacturers, the CleanBlastPRO is equipped with a refillable internal solvent tank, intuitive LCD interface, and a handset that supports a comprehensive selection or precisi...
VIAVI CleanBlastPRO: Changing Filters
Переглядів 39Рік тому
The CleanBlastPRO from VIAVI Solutions is a fiber optic end-face cleaning system that provides an automated cleaning process to ensure clean fiber connector end-faces at the press of a button. Ideal for fiber connectivity manufacturers, the CleanBlastPRO is equipped with a refillable internal solvent tank, intuitive LCD interface, and a handset that supports a comprehensive selection or precisi...
VIAVI CleanBlastPRO: Handset Controls
Переглядів 39Рік тому
The CleanBlastPRO from VIAVI Solutions is a fiber optic end-face cleaning system that provides an automated cleaning process to ensure clean fiber connector end-faces at the press of a button. Ideal for fiber connectivity manufacturers, the CleanBlastPRO is equipped with a refillable internal solvent tank, intuitive LCD interface, and a handset that supports a comprehensive selection or precisi...
VIAVI CleanBlastPRO: Cleaning Multi-Fiber Connectors
Переглядів 110Рік тому
The CleanBlastPRO from VIAVI Solutions is a fiber optic end-face cleaning system that provides an automated cleaning process to ensure clean fiber connector end-faces at the press of a button. Ideal for fiber connectivity manufacturers, the CleanBlastPRO is equipped with a refillable internal solvent tank, intuitive LCD interface, and a handset that supports a comprehensive selection or precisi...
Test-Tipps: Messung von Reflexion/Rückflussdämpfung und DTF mit dem Kabel- und Antennen-Analyse-Modu
Переглядів 216Рік тому
PLM Eduardo Inzunza von VIAVI erläutert die Ausführung dieser wichtigen Messung für die Installation von Basisstationen mit dem CAA-Modul für den OneAdvisor 800 und den CellAdvisor 5G. Er zeigt, wie einfach sich mit der richtigen Prüf- und Messtechnik noch vor Ort die Reflexion/Rückflussdämpfung an einer Zubringerleitung sowie die Entfernung zur Fehlerstelle (DTF) bestimmen lässt.
操作方法测试技巧:电缆和天线分析模块的回波损耗和 DTF
Переглядів 138Рік тому
VIAVI 产品线经理 Eduardo先生 解释了如何使用天馈线测试仪模块对基站安装进行基本测试,该模块可与 OneAdvisor 800 CellAdvisor 5G 配合使用。Eduardo 展示了使用正确的测试设备,在现场快速有效地测量馈线上的反射回波损耗以及故障距离 (DTF) 是多么方便。
以前は SmartOTU と呼ばれていたスタンドアロンモードで FTH を使用してファイバールートを文書化するための KML 形式の要件
Переглядів 27Рік тому
KML ファイルを適用してファイバールートを文書化すると、VIAVI FTH モニタリングを使用して、ランドマークでマップ分析で障害をキャプチャできるため、障害の場所にディスパッチすることで MTTR を削減できます。
操作方法测试技巧:5G 小区相位同步
Переглядів 70Рік тому
相邻的蜂窝基站应该被安排成使得它们各自的覆盖区域稍微重叠。这样,当最终用户在覆盖区域内移动时,他们不会通过死角。然而,蜂窝基站必须紧密同步,以防止它们相互干扰。VIAVI PLM Eduardo Inzunza 解释了如何使用 OneAdvisor 800 和 CellAdvisor 5G 根据 3GPP 标准测试相邻蜂窝基站的同步。
Test-Tipps: Phasensynchronisation zwischen 5G-Funkzellen
Переглядів 50Рік тому
Die Mobilfunkzellen sollten so angeordnet sein, dass sich die jeweils abgedeckten Gebiete etwas überlappen. So kann verhindert werden, dass beim Wechsel zwischen den Versorgungsbereichen der benachbarten Funkzellen die Kommunikation zwischen den Endgeräten unterbrochen wird. Allerdings müssen die Basisstationen exakt synchronisiert sein, damit sie sich nicht gegenseitig stören. In diesem Video ...
KML-Formatanforderungen zur Dokumentation von Glasfaserstrecken mit dem FTH im Standalone-Modus (vor
Переглядів 210Рік тому
KML-Formatanforderungen zur Dokumentation von Glasfaserstrecken mit dem FTH im Standalone-Modus (vor
How-To Test Tips: Reflection Return Loss and DTF with the Cable and Antenna Analysis Module
Переглядів 1 тис.Рік тому
How-To Test Tips: Reflection Return Loss and DTF with the Cable and Antenna Analysis Module
How to Perform the Calibration Procedure on the CX300 Cable and Antenna Analysis Option (SCAA)
Переглядів 466Рік тому
How to Perform the Calibration Procedure on the CX300 Cable and Antenna Analysis Option (SCAA)
How-To Test Tips: TDD Automated Gated Spectrum
Переглядів 309Рік тому
How-To Test Tips: TDD Automated Gated Spectrum
AVX-10K Training - Registering Your Device with StrataSync
Переглядів 508Рік тому
AVX-10K Training - Registering Your Device with StrataSync
AVX-10K Training - Using the Utility Tray
Переглядів 179Рік тому
AVX-10K Training - Using the Utility Tray
AVX-10K Training - Performing the VOR Test
Переглядів 306Рік тому
AVX-10K Training - Performing the VOR Test
Formation AVX-10K - Utiliser les applications TOS et DTF
Переглядів 43Рік тому
Formation AVX-10K - Utiliser les applications TOS et DTF
Formation AVX-10K - Exécution du test DME
Переглядів 13Рік тому
Formation AVX-10K - Exécution du test DME
AVX-10K Training - Performing the ILS Test
Переглядів 230Рік тому
AVX-10K Training - Performing the ILS Test
Formation AVX-10K - Utilisation de ADS-B Monitor et UAT Monitor
Переглядів 15Рік тому
Formation AVX-10K - Utilisation de ADS-B Monitor et UAT Monitor
Formation AVX-10K - Exécution de l’auto-test ADS-B
Переглядів 22Рік тому
Formation AVX-10K - Exécution de l’auto-test ADS-B
Formation AVX-10K - Paramètres système standard et préférences générales
Переглядів 23Рік тому
Formation AVX-10K - Paramètres système standard et préférences générales
Formation AVX-10K - Exécution de l’auto-test de transpondeur
Переглядів 36Рік тому
Formation AVX-10K - Exécution de l’auto-test de transpondeur
Buen dia me pueden explicar por favor como se revisa el SNR en el equipo por favor!!
Buenas tardes. No queda claro como realizar la Conexion al celular del técnico que está en campo. Se podría aclarar ese punto? Gracias! Slds !!
Traga a versão antiga de volta pelamordeDeus
Is this software free for the ones buying Viavi Otdr ?
Copper sucks, period.
I already made an order to buy it but how can I make a full test power meter with a loss test to take panduit warranty
Hi can you answer a question ?
So if i buy this device it comes without a light source?
Excellent video! How can we get this Powerpoint or PDF of this?
Comment utiliser le OTDR merci
Why 1550 loss lesser than 1310nm
Because of the absorption characteristics of the glass material in the fiber.
Thank you, Can you create a real life video to guide on while you perform the test on a plane so it can be easy for us to follow? Eg, when you mentioned that the xponder must be transimiting, how is that achieved? Do yo u turn it on in the cockpit?
Why is there no information on setting up the antenna?
Amigo vc compra esse aparelho , achei um aparelho desse ele ta funcionando
Quanto custa um aparelho desse ? Achei um e ate hoje nao apareceu dono
Me encontré un aparato de esos en la carretera. Donde lo puedo llevar. Vivo en tampa Fl
Grate
I have a question, what is the software or program to view my files downloaded from the OLTS-85P device on my computer?
what does RFC stands for?
Without saved report is there any stored internaly
Bom dia, tenho um OTDR desse modelo, como calibrar a tela dele...sempre usei mouse...
Este modelo não tem como calibrar manualmente a não ser na assistencia tecnica ou utilização de um mouse.
Como eu passo informações do OTDR para meu celular sem precisar de pen drive?
vc poderia utilizar a opção SmartAccessAnywhere (caso tenha licença) , via ftp e tambem via bluetooth
Como faço para gerar uma "certidão de nascimento".?
A certidao de Nascimento ela pode ser aplicada por algumas normas ou padroes. As mais utilizadas e comuns sao RFC 2544 e Y.1564. existem dois Videos explicando cada uma delas detalhadamente
Parabéns muito bem explicado. Gostaria de saber como eu configuro os IPS para iniciar os testes
Não estou conseguindo transferir arquivo para o pendrive
Información muy importante
Son of a bitch. I kept driving way out to reboot the damn thing on site
Hola súper bien explicado
Olá sou de Fortaleza e quero fazer um curso completo da viavi como que faço?
Can you give bangole language
Victor do Brasil, muito obrigado seu vídeo me ajudou bastante!
I can't find the video which explains the process to download the test report. Please help.
Wifi advisor app is not working, is their a work around or web site. Or is the app taken off the app store??
Hola este medidor sirve para 3.0
Si 3.0 y 3.1
I need an OTDR that can measure loss on a fiber with just 1 connector spliced on. The slide at 8:13 says the OTDR sends a signal into one end and analyzes the backscatter and reflected signal. Does this happen or work with nothing on the end of the fiber? I would be plugging an SC terminated side into the OTDR and the other end is just cut, un-connectorized fiber.
Trabalho com um MTS 5801, ao ligar o equipamento o cursor fica no centro da tela, quando dou o primeiro toque o cursor sobe para a parte superior do lado direito e não é mais possível mover o cursor. Não consigo selecionar nenhuma opção e ao clicar algumas vezes na tela, fica travada. Alguma indicação do que pode ser?
Teclado do otdr viavi não está funcionando algumas letras,o que faço
Me gustaría saber como cambiar de archivo csor. Ah msor
Boa tarde, na empresa que trabalho usamos o VIAVI SMARTOTDR, antes conseguiamos enviar relatorio para o celular, agora não estamos conseguindo, será que tem que fazer alguma configuração? Alguém já te esse mesmo problema aqui no grupo? Ficarei grato se alguém poder me ajudar
Conseguiu solucionar amigo ?
MEU VIAVI NAO TEM A OPCAO FIBER TO THE HOME , COMO BAIXO ESSE SOFTWARE?
This the best of the best OTDR video ever done👍
Was reading Wikipedia of the history of this company and realized most of the equipment I have used working in wireless became Viavi. Acterna, TTC, JDSU and Wavetek. Made me realize I am getting old! 😅
boa tarde atualizaei ficou na versao chinesa , quando comprei estava em pertugues , comprei na China , alguem poderiam mim ajuda pago pelo serviço
Buenas tardes su apoyo para el uso del tdr de l viavii ONX580
Thank you for such a valuable training video, 🎉.
Please sir , could you please show me how to plug the Adapter of VIAV Smart OTDR if I want to power it on?
Cara muito pratico..
thanks for your analysis. please what is the difference between complete and pass then?
A test can be complete but the circuit could still fail. A pass means that the test has been marked complete and has met the pre-established transmission performance target. Hope that helps! Thanks for watching.
@@ViaviSolutions thanks for your prompt response. does this mean that in the demonstration (the ones that were complete with blue tick meant that this is inconclusive? i am asking simply because we are in a situation right now were we unsure what the blue means and we are using your testers. does this mean that we need to check if our test actually failed? please your response again will be appreciated.
@ViaviSolutions I too we are facing this issue in our network and our customer is very unhappy that we can't explain this behavior. Please what does this mean when you say circuit failure? When there is a circuit failure then why are you getting a passed throughout ? Pls i need help . Can I call customer service to get help. We are in big trouble with our customer as we are lost now
Can someone explain " battery" a little more in depth?
What do you want to know ask me? When they're talking about battery they just mean that the equipment vrad or DSLAM from the remote or office puts electricity on the cable pair. It's normally between 48 and 52 volts.
Hello, do anyone know why this test set do not connect to hard coded full duplex? Or anyone know how to test through Full duplex hard coded, I have to change my switch to auto in order for this to work. Kinda annoying, why it do not connect. :) Thank you.
How can we connect and "copy file/link to all" the 2 T-BERD if it's far from each other like for example they are 2 km away?