Power Electronics Lecturer Notes
Power Electronics Lecturer Notes
  • 38
  • 344 472
OptoCoupler POWER LOSS Calculation (PART-2)
OptoCoupler POWER LOSS Calculation.... How to Choose OptoCoupler? ... OptoCoupler selection method............
How to select Optocoupler? PART-1
ua-cam.com/video/5-xJ54NMkR4/v-deo.html
Переглядів: 363

Відео

Diode Power Loss Calculation & Compare with Schottky Diode Power Loss
Переглядів 1473 місяці тому
How to calculate power loss for PN Junction diode... general purpose diode.... schottky diode..... why it is important.....
How to select Optocouplers? (Operation, Specification, Applications)
Переглядів 6543 місяці тому
Optocouplers Operation.. Optocouplers Specification... Optocouplers Applications....Basic Operation, Selection Parameters, Specifications, Datasheet walk through, Advantages
Buck Converter Output Capacitor Value Calculation
Переглядів 2,4 тис.Рік тому
How to calculate minimum output capacitance required for the buck converter.. It will be similar to other DC to DC converters also like Book Converter, Buck-Boost converter, SEPIC Converter.... By replacing the required values from the converter input specifications in the capacitor equation, we can find the minimum required capacitor value in the SMPS converter...
Buck Converter Inductor Value Calculation Guide
Переглядів 5 тис.Рік тому
Tutorial for DC to DC buck converter Inductor value calculation... How To Select Inductor for Buck Converter?. start with voltage across inductor v =L. (di/dt).. Apply various parameters from the customer input specifications for the DC to DC converter like switching frequency, expected ripple voltage at the output... Buck Converter Inductor section Guide...
MOSFET Power Loss Calculation: Step by Step Approach
Переглядів 8 тис.Рік тому
What are the various losses in Power MOSFET How to Calculate losses in MOSFET Formulas to calculate losses in MOSFET How to minimize losses in MOSFET
RC Circuit Operation, Formula, Time Constant Equation Derivation
Переглядів 350Рік тому
Capacitive taransient circuit understanding... Resistor Capacitor charging and discharging process explained in detail...RC Circuit Charging, RC Circuit Discharing equations derrivation....RC Circuit Operation....Capacitive transient Time Constant Equation Derivation
MOV vs TVS Diode
Переглядів 1,3 тис.Рік тому
Difference between Metal Oxide Varistor (MOV) and TVS Diode... Transient Voltage Suppressor... Surge voltage protection devices... Which is better device for over votlage protection? Important Hardware engineer interview question is answered in this video.
How to Hide ToolsPane in PDf files Automatically? Settings for Tools Bar will not appear by default
Переглядів 2013 роки тому
How to change the setting in Adobe reader so that the tools place will not appear by default... How to hide Tools Pane in PDf files forever?
Why 3 phase system for electricity distribution?
Переглядів 653 роки тому
why electricity distributed as 3 phase system? Why 3 Phase System used in Transmission & Distribution? Most of mains power sockets are single phase, Utilities are in DC But, Power stations generate three phase AC at 120° from each other. Why? The advantage of this is that 3x120° = 360°. In other words, the phases cancel out when connected to a common point.
Why 230V Power Supply Used in India &115V, 60Hz in USA
Переглядів 3653 роки тому
Why 230V, 50Hz power system in India &115V, 60Hz power system in USA.... which power system is best?
Why 115V 400Hz used in Aircraft Power System?
Переглядів 10 тис.3 роки тому
Aircraft uses 115V 400hz Power. Why high frequency is used... FAA = Federal Aviation Administration
What is Power Factor? Definition, Causes, Impact of low Power Factor
Переглядів 3554 роки тому
What is Power Factor?.. Power Factor- Definition, Causes of low Power Factor, Impact of low Power Factor.. Reduction of electricity bills, Extra kVA available from the existing supply Reduction of I2R losses in transformers and distribution equipment, Reduction of voltage drop in long cables, Extended equipment life - Reduced electrical burden on cables and electrical components
How to select Resistor Value, Rating for LED Circuits?
Переглядів 774 роки тому
How to Select Resistor Value, Rating in LED Circuits... The very first project to do in electronics is turn on LEDs, and control the brightness...
Power Factor Correction: Basic Terminology - Part:1
Переглядів 2014 роки тому
What is meant by Power Factor? Types of Power Factor? Causes of low Power Factor? Impact of low Power Factor? Power Factor Improvement Methods/Types? what is meant by Harmonics? Why improve power factor ? Environmental benefit. Reduction of power consumption due to improved energy efficiency. Reduced power consumption means less green house gas emissions and fossil fuel depletion by power stati...
Triangular Wave RMS Value Calculation
Переглядів 67 тис.5 років тому
Triangular Wave RMS Value Calculation
Sine Wave RMS Value Calculation
Переглядів 54 тис.5 років тому
Sine Wave RMS Value Calculation
Sine Wave With DC Offset RMS Value Calculation
Переглядів 7 тис.5 років тому
Sine Wave With DC Offset RMS Value Calculation
Half Wave Rectifier Efficiency, RMS Current Calculation - Step by Step Explanation
Переглядів 2,5 тис.6 років тому
Half Wave Rectifier Efficiency, RMS Current Calculation - Step by Step Explanation
How Half Wave Rectifier Works? Operation, Irms Derivation Part#1
Переглядів 1306 років тому
How Half Wave Rectifier Works? Operation, Irms Derivation Part#1
How Freewheeling Diode Works
Переглядів 14 тис.6 років тому
How Freewheeling Diode Works
How does Tank Circuit Work?
Переглядів 23 тис.6 років тому
How does Tank Circuit Work?
How Flyback Converter Works?
Переглядів 25 тис.7 років тому
How Flyback Converter Works?
Opamp Circuit Problems With Solution Part 1
Переглядів 5 тис.7 років тому
Opamp Circuit Problems With Solution Part 1
HOW CLASS-D CHOPPER WORKS?
Переглядів 1,2 тис.7 років тому
HOW CLASS-D CHOPPER WORKS?
Potentiometer Basics Operation Working Connection
Переглядів 7158 років тому
Potentiometer Basics Operation Working Connection
Multimeter Basic Troubleshooting Tips
Переглядів 548 років тому
Multimeter Basic Troubleshooting Tips
Multimeter Battery Replacement Tutorial
Переглядів 2,6 тис.8 років тому
Multimeter Battery Replacement Tutorial
How to test Diode with multimeter
Переглядів 4,6 тис.8 років тому
How to test Diode with multimeter
How to test LED Using Multimeter?
Переглядів 2,6 тис.8 років тому
How to test LED Using Multimeter?

КОМЕНТАРІ

  • @priyadharshinikp8840
    @priyadharshinikp8840 13 днів тому

    Thank you sir

  • @vikasgupta-hl9sq
    @vikasgupta-hl9sq Місяць тому

    Nice

  • @saeidghorbani1846
    @saeidghorbani1846 2 місяці тому

    Hello, to protect the triac part from half burning, you suggest to use Diode Tvs Is it or varistor?

  • @mohdrashid1483
    @mohdrashid1483 2 місяці тому

    sir apna audio mic clarity improve karo, speed and cofident ho kar bolo, voice countinue flow hona chahiey , atak atak kar mat bolo , quality ka video hone ke babjood dekhne main maja nahi aa raha hai.

  • @RakeshKumar-ty2hf
    @RakeshKumar-ty2hf 3 місяці тому

    Hello sir Please make a video for toroid core selection in buck convert

  • @DarvinR-gx9zs
    @DarvinR-gx9zs 3 місяці тому

    Perfect video for opto coupler ,pls cover mosfet,opamp selection

  • @SanjaySharma-pw6ww
    @SanjaySharma-pw6ww 3 місяці тому

    nice video on optocuplers

  • @thetruthchristmedia9473
    @thetruthchristmedia9473 5 місяців тому

    You find the area but you are not using not clear form what you did

  • @novosur1676
    @novosur1676 8 місяців тому

    can this type of generator 3fase be used to power an bldc motor

  • @SuperPutzPutz
    @SuperPutzPutz 9 місяців тому

    😊 is the 7805 the same thing as a LM317?

    • @donrixw9955
      @donrixw9955 2 місяці тому

      no 7805 is not adjustable but lm317 is

  • @nehro94
    @nehro94 Рік тому

    The last equation is not correct, you substitute the vout/vin in the place of D, how can you write the D again in the equation

    • @powerelectronicslecturernotes
      @powerelectronicslecturernotes Рік тому

      I agree with you. D = Vo/Vin for buck converter. once it is expanded in the equation, it has to be removed (so final equation should contain either D or Vo/Vin....

  • @checkthelastmonday61
    @checkthelastmonday61 Рік тому

    How does u(t) become Vm.Sin(ωt) ?

  • @TejaswiniMuttineni-uk8ul
    @TejaswiniMuttineni-uk8ul Рік тому

    Tnx u sir

  • @42gopikrishnac57
    @42gopikrishnac57 Рік тому

    good explanation sir

  • @ChrisLaudenschlager
    @ChrisLaudenschlager Рік тому

    Nice and simple! Thank you. Do you have this power point available for download or a blog page where we can view this information?

  • @AllanManzunzu
    @AllanManzunzu Рік тому

    Nice

  • @PreludeSon
    @PreludeSon Рік тому

    Great illustration. Some part I didn't quite hear it very well but this is so well illustrated. Thank you

  • @jboy4real
    @jboy4real Рік тому

    Kindly do video for practical design of powder iron core inductor for buck converter. Thanks

  • @device786
    @device786 Рік тому

    Sir what's parabola law find the provide..

  • @SaiKrishna-hj4ci
    @SaiKrishna-hj4ci Рік тому

    Good explanation sir

  • @kaizenkitchenaids8081
    @kaizenkitchenaids8081 Рік тому

    Hi,saw your video on power supply of airplanes,just wondering whether the power supply is 115 volts 400 hz single or 3 phase?

  • @hohoking5150
    @hohoking5150 Рік тому

    Thank you for your very clear and educational video!

  • @lysthonkabuba7113
    @lysthonkabuba7113 Рік тому

    Hi there. I would like to have some information. I have a 115V/400Hz aircraft generator and would like to transform it into house generator (220V / 340V 3PHASE). What can I do?

  • @aayushkumawat9354
    @aayushkumawat9354 Рік тому

    Sir why not take interval 0 to Pai please reply sir

  • @mayukhchakraborty445
    @mayukhchakraborty445 2 роки тому

    Worthless

  • @madakasaikumar7785
    @madakasaikumar7785 2 роки тому

    Good 😊

  • @Od9fj3oe829
    @Od9fj3oe829 2 роки тому

    Thank you Sir

  • @zandilekusasa9071
    @zandilekusasa9071 2 роки тому

    Poorly done

  • @dennis1954
    @dennis1954 2 роки тому

    Even so that it was difficult to fully understand your English your presentation made it clear as to why the diode is needed. Many thanks.

  • @NiteshKumar-pt2wg
    @NiteshKumar-pt2wg 2 роки тому

    Finally got it🙏thanks

  • @Chandradarling
    @Chandradarling 2 роки тому

    Tq sir

  • @jyothipriya8394
    @jyothipriya8394 2 роки тому

    Thank you

  • @martinlicht1969
    @martinlicht1969 2 роки тому

    Thanks, so far you're the only person helping with pin identification. Thankyou, thankyou! I know a few viewing this had trouble understanding so maybe I can translate. The plus and minus signs on rectifier body are diagnal from each other. The other 2 diagnal pins are AC in. The plus and minus leads are the DC out. The schematic shows what's inside a single phase bridge rectifier, but as you can see, one could make with 4 diodes. Hope that helps.

  • @shillout7270
    @shillout7270 2 роки тому

    This is not full test. It's easy to identify terminals when they are already marked. Click bait !!

    • @martinlicht1969
      @martinlicht1969 2 роки тому

      I know what you mean; I'm kind of a dummy here but can see now that if your rectifier body is not labeled; the longest lead is the +. The minus will be diagonally located. But say the leads have been cut? Then a continuity check with a meter can deduce the terminal ID.

  • @abdulkalamshaik5007
    @abdulkalamshaik5007 2 роки тому

    Clarity on integration of RMS value missing

  • @Orangestown
    @Orangestown 2 роки тому

    Thank you!

  • @henrytzuo8517
    @henrytzuo8517 2 роки тому

    THANK YOU, I SEE!

  • @caset3509
    @caset3509 3 роки тому

    ♥️♥️♥️♥️

  • @VASUDHARANIPATHEDAMIS
    @VASUDHARANIPATHEDAMIS 3 роки тому

    I am ur 1k subscriber very nice explanation sir

  • @rehmanahmed763
    @rehmanahmed763 3 роки тому

    sir there shoudn't be any square at 8:11

  • @karl-heinzblass6098
    @karl-heinzblass6098 3 роки тому

    Thankyou very much for the details. I was asked to install a 230V/50Hz to 115V/400Hz converter. How do i know that the waveform is near to sinus and not square/triangle. Can you recommend anything?

  • @inforneer
    @inforneer 3 роки тому

    it was great! thanks! however, do you know why some manufactures only produce 200/208V outlet in 400Hz these days?

  • @Buzzhumma
    @Buzzhumma 3 роки тому

    Accent was too strong for me to understand somebody teaching about something technical while trying to figure out how they can say it while reading some of the text! Constructive criticism! Best to write down what you are going to say and regulate the speed and i think i will be fine !

  • @thelazyyoutuber6474
    @thelazyyoutuber6474 3 роки тому

    There is no OK button after checking the box. plz help

  • @shubhampatel4879
    @shubhampatel4879 3 роки тому

    Nice explaination

  • @ishabarkat6177
    @ishabarkat6177 3 роки тому

    Nice 👍 Sir

  • @rohithj.e9254
    @rohithj.e9254 3 роки тому

    Thanks

  • @hairomana4255
    @hairomana4255 3 роки тому

    Thanks for your explanation

  • @shivannarasareddy1931
    @shivannarasareddy1931 3 роки тому

    Nice explained