Midwest HVACR Technician
Midwest HVACR Technician
  • 21
  • 13 519
Rooftop Unit Heat Exchanger Replacement
Replaced 2 Heat Exchangers today as it was a beautiful morning, no wind and the temperature was great! We have some colder weather coming soon so I wanted to get some of the more important repairs done on a nice day
Enjoy the video and have a great weekend everyone!
#hvacr #hvacrtechnician #hvacrepair #servicecall #hvac #hvacmaintenance #refrigeration #refrigeration_ #refrigerationsystems
Переглядів: 355

Відео

HVAC/Refrigeration Service Technician Van Setup 2024HVAC/Refrigeration Service Technician Van Setup 2024
HVAC/Refrigeration Service Technician Van Setup 2024
Переглядів 2 тис.3 дні тому
Here is what my service vehicle is setup with, I carry multiple tools and parts for anything I may run into on a daily service call. Merry Christmas, Happy Holdiays, and Enjoy the New Year 2025. Hope everyone stays safe and let’s start 2025 off on the right foot! Keep learning and enjoy yourselves #hvacr #hvacrtechnician #hvacrepair #refrigeration #servicecall #hvac #hvacmaintenance #refrigerat...
Rooftop Unit Heating Maintenance Repairs #hvacrtechnician #hvacr ##hvacservice #hvacrepairRooftop Unit Heating Maintenance Repairs #hvacrtechnician #hvacr ##hvacservice #hvacrepair
Rooftop Unit Heating Maintenance Repairs #hvacrtechnician #hvacr ##hvacservice #hvacrepair
Переглядів 2894 дні тому
Sorry for the vertical video, I completely forgot I hope you guys enjoy the process that I went through to get this Rooftop Unit Heating so the employees inside are warm before the cold weather really hits us up here in the Midwest #hvacr #hvacrtechnician #servicecall #hvacrepair #hvac #hvacmaintenance
Check those fan blades!! #hvacr #refrigeration #hvacrtechnician #servicecallCheck those fan blades!! #hvacr #refrigeration #hvacrtechnician #servicecall
Check those fan blades!! #hvacr #refrigeration #hvacrtechnician #servicecall
Переглядів 1,1 тис.5 днів тому
Subcooler Sensor Failure #hvacrtechnician #hvacr #refrigerationSubcooler Sensor Failure #hvacrtechnician #hvacr #refrigeration
Subcooler Sensor Failure #hvacrtechnician #hvacr #refrigeration
Переглядів 1768 днів тому
Replaced a Subcooler Sensor (Monitoring) and made sure that the new sensor was reading what the Sporlan Subcooler Controller (Controlling the setpoint) was reading #hvacr #refrigeration #hvacrepair #hvacrtechnician #servicecall #hvac #hvacmaintenance #refrigeration_ #refrigerationsystems
Exhaust Fan Replacements X5 #hvacr #hvacrtechnician #hvacrepairExhaust Fan Replacements X5 #hvacr #hvacrtechnician #hvacrepair
Exhaust Fan Replacements X5 #hvacr #hvacrtechnician #hvacrepair
Переглядів 3111 днів тому
Replaced 5 exhaust fans due to an extreme wasp infestation, this caused the motors to fail and the exhaust fans haven’t ran for years and I figured they should have these exhaust fans running. The main bathroom exhaust fan has been one of those and you can already smell the difference 🤣 #hvacr #hvacrepair #hvacrtechnician #servicecall #hvac #hvacmaintenance #refrigeration #refrigeration_ #refri...
RTU Heating, Ice Machine, and Walk-In Cooler MaintenanceRTU Heating, Ice Machine, and Walk-In Cooler Maintenance
RTU Heating, Ice Machine, and Walk-In Cooler Maintenance
Переглядів 485Місяць тому
In this video, you will see a rooftop unit heating inspection and an ice machine Maintenance along with a inspection of the walk-in cooler  While I was editing this video, I did see that the defrost clock for the walk-in cooler was missing a pin and I did have a couple back in my van so I did end up putting the four pins for the defrost on the defrost clock #hvacrtechnician #refrigeration #hv...
Rack Compressor Changeout X2 #refrigeration #hvacrRack Compressor Changeout X2 #refrigeration #hvacr
Rack Compressor Changeout X2 #refrigeration #hvacr
Переглядів 725Місяць тому
Replacing 2 Carlyle Compressors in one day as we’re pretty busy and this was the only time with a few extra guys available. Biggest problem was the 2 compressors could not be fully isolated because of the discharge valves not holding and bleeding pressure into the compressor and it was around 150psi worth. So the night before we replaced the valves and made sure no other valves were leaking. Di...
4CES Compressor Replacement4CES Compressor Replacement
4CES Compressor Replacement
Переглядів 541Місяць тому
Replaced a compressor that another technician quoted to have replaced due to the compressor “vibrating extremely bad and sounding like rocks” I’m working on not saying “Alright” all the time 🤣 #hvacrtechnician #refrigeration #hvacr #hvacrepair #refrigerationsystems #refrigeration_ #servicecall #hvac #hvacmaintenance
Condenser Coil Replacement #refrigeration #hvacr #hvacrepairCondenser Coil Replacement #refrigeration #hvacr #hvacrepair
Condenser Coil Replacement #refrigeration #hvacr #hvacrepair
Переглядів 6332 місяці тому
Replaced a Remote Condensing Unit Condenser Coil today as the coil discharge header was bent, which caused a rub through on the copper. As you can see in the video, all the other lines were bent on the header also going into the coil. Replacing this coil was the best option as we don't want all 7 of these cases going down for a leak when we can just replace the coil now and not have to worry ab...
TXV Replacement on a Ice Cream Case #refrigeration #hvacr #hvacrtechnician #hvacrepairTXV Replacement on a Ice Cream Case #refrigeration #hvacr #hvacrtechnician #hvacrepair
TXV Replacement on a Ice Cream Case #refrigeration #hvacr #hvacrtechnician #hvacrepair
Переглядів 2242 місяці тому
Sunday call for a Ice Cream case that was not getting below 25deg. Upon arrival ensured no heaters were on and our suction line temp would not drop with any adjustment I did on the TXV. Decided to replace the TXV and add a suction ball valve in, as I had them on my van and I am extremely busy this week, also so I could get the other 2 out of 3 ice cream cases on while I work on this one that I ...
FloCon A9 Install (Receiver Re-Pressurization) #refrigeration #hvacr #refrigerationsystemsFloCon A9 Install (Receiver Re-Pressurization) #refrigeration #hvacr #refrigerationsystems
FloCon A9 Install (Receiver Re-Pressurization) #refrigeration #hvacr #refrigerationsystems
Переглядів 3482 місяці тому
Removing faulty existing repressurization valves for the receiver and installing a A9 valve for better control.

КОМЕНТАРІ

  • @jameswitham7938
    @jameswitham7938 4 години тому

    Awesome video, I’ve been in HVAC the past year and a half in school and working residentially. I watch a large variety of content for tool/van setups and general knowledge in the industry. Really impressed about your video for a few reasons. Firstly, it’s from a Midwest tech! I’m in Michigan and don’t find much Midwest content in HVAC. The carpet setup is really cool and I like how you tag all equipment too- I’ve already noticed how critical communication is in the trade for safety and for proper practices. Looks like I have another channel to subscribe to, and some more videos to watch tonight. Looking forward to the 2025 content to come! James

    • @MidwestHVACRTech
      @MidwestHVACRTech 3 години тому

      @@jameswitham7938 Thank you James, I really appreciate the nice comment from another Midwest Tech. I hope school is going well for you. If you have any questions you need answered, feel free to comment and I'll do my best to answer.

  • @alejandrozometa1951
    @alejandrozometa1951 13 годин тому

    Lowkey miss my transit but they gave us pick up trucks 2500 they’re bad ass to

    • @MidwestHVACRTech
      @MidwestHVACRTech 8 годин тому

      @@alejandrozometa1951 I would line a truck that has a nice storage system as I know they are very quiet and nicer ride

  • @sherwinalvarez7365
    @sherwinalvarez7365 17 годин тому

    What is the PN for the larger service wrench. All the one i have a hex on one side and the smaller service wrench sizes on the other.

  • @cassgil8448
    @cassgil8448 День тому

    Great video man, looks pretty well stocked and organized. If you had time to show off your maintenance bag, I'd love to see it too

    • @MidwestHVACRTech
      @MidwestHVACRTech 21 годину тому

      @@cassgil8448I’ll do a short video on that here this next week for you!

  • @easkeybikes1966
    @easkeybikes1966 День тому

    What brand / size van is that?

  • @fernandoboss1740
    @fernandoboss1740 2 дні тому

    IS NOT S AND K ITS JUST SK

  • @WswRefrigeration
    @WswRefrigeration 2 дні тому

    Almost as easy as a Carrier

  • @c21meister
    @c21meister 2 дні тому

    Can you fit a 5 ton condenser and air handler in the middle?

    • @MidwestHVACRTech
      @MidwestHVACRTech 2 дні тому

      I would have to measure but I can fit a lot in the center, even with the packrat

  • @MidwestPipefitter
    @MidwestPipefitter 3 дні тому

    I love the video. My favorite part is just seeing how much material you have at all times. All of the little pieces of equipment. It’s like a little wholesale house in your van!

  • @leonardflores9665
    @leonardflores9665 3 дні тому

    I had to go to the local automotive supply house and get my house replaced because when I called the AC dealer they don't sell hoses by themselves you have to buy the $300 inducer motor that comes with a hose

  • @airlife2u
    @airlife2u 5 днів тому

    😂 You found one of them ancient Wheels from 800 Bs.. times....😮 Even scientists have a hard time figured out what this is... But it looks like this man has figured it out...❤❤❤😊The Ancient alien people will be very thankful for you And your time😅

  • @MidwestHVACRTech
    @MidwestHVACRTech 5 днів тому

    Manufacturer said to replace the fan blades per their new PN so we will see how these new fan blades hold up.

  • @brugley1090
    @brugley1090 5 днів тому

    not sure about that

  • @romeoryan869
    @romeoryan869 8 днів тому

    Truck tour Mann!! ❤😂

  • @tonyfremont
    @tonyfremont 13 днів тому

    I hope you put a new spade connector on it. Thats from a loose connection.

    • @MidwestHVACRTech
      @MidwestHVACRTech 13 днів тому

      I was able to fix the loose connection, correct

  • @kobie4238
    @kobie4238 26 днів тому

    Nice video, also nice van setup!

  • @lj6672
    @lj6672 Місяць тому

    Great video, I never worked on anything so clean

    • @MidwestHVACRTech
      @MidwestHVACRTech Місяць тому

      Haha this Rack was just installed last year so I’m hoping we keep it clean!

  • @JP-sd2cw
    @JP-sd2cw Місяць тому

    what torches do you use?

    • @JP-sd2cw
      @JP-sd2cw Місяць тому

      what % of silfos was that? was flowing really nice

    • @MidwestHVACRTech
      @MidwestHVACRTech Місяць тому

      @@JP-sd2cw I use the Sil Fos 15 and I used my big torch tip as I like to get it hot quick and done

    • @JP-sd2cw
      @JP-sd2cw 27 днів тому

      @@MidwestHVACRTech do you kno the brand like if they are Harris, power weld or Victor?

    • @MidwestHVACRTech
      @MidwestHVACRTech 27 днів тому

      @ I’m pretty sure I have different brands but currently I have Lucas Milhaupt

  • @JP-sd2cw
    @JP-sd2cw Місяць тому

    you sound canadian!!

  • @maheradous9257
    @maheradous9257 Місяць тому

    Good job 👍

  • @maheradous9257
    @maheradous9257 Місяць тому

    Good job 👍

  • @MrJEEPJT
    @MrJEEPJT Місяць тому

    🤬🤬 Cheap Bastard customers can’t spend the money for a walk in trailer machine room now all we have is these crappy small units that the technician will be exposed to rain and snow while troubleshooting, not to mention the electrical section where the E-2 or Danfoss controller and all the contacters and input, output boards are located.

  • @scottvanslooten8374
    @scottvanslooten8374 2 місяці тому

    Probably better off to just replace the unit depending on age

    • @MidwestHVACRTech
      @MidwestHVACRTech 2 місяці тому

      @@scottvanslooten8374 Thanks for the suggestion, currently no reason other than just a coil. Everything else is in great working order. Unit is from 2016

  • @navjotsingh-lr6nn
    @navjotsingh-lr6nn 2 місяці тому

    Thank you for video

  • @MidwestPipefitter
    @MidwestPipefitter 2 місяці тому

    What does it mean when the compressor is isolated?

    • @MidwestHVACRTech
      @MidwestHVACRTech 2 місяці тому

      @@MidwestPipefitter A “Isolated Compressor” is when that compressor is still technically attached to the system but all valves are closed which isolates the compressor. So here we shut the Oil inlet and equalization line, the Suction and Discharge line, and since the power is shut off the liquid injection solenoid is powered off so I trusted that the solenoid held/sealed properly. Which is why I keep my hoses on the compressor and see if any pressure rises. We isolate compressors so we can safely work on the internal components, inspections of gaskets/valve plates, and doing overall maintenance as well. Also if a compressor stops doing what it’s supposed to do then we want to shut it down and isolate it because if we have a broken compressor then you may have high discharge pressure leaking into the low suction pressure which will make bigger issues.