The Irrigation Guy
The Irrigation Guy
  • 6
  • 10 068
Christmas Tree Stand
A DYI Christmas tree stand project. When you buy the wrong tree stand and then cut down the tree in the front yard you need a quick fix and this was mine. Rope, a bucket and a 2 x 4 to make a quick tree stand. A fun little project and supports our 9 foot tree no problem. I hope you enjoy the video.
Переглядів: 69

Відео

BL-Cloud-LTE
Переглядів 763 роки тому
How to install the Baseline cloud network cellular card. A step by step tutorial. Hardware install and software setup.
Baseline Ethernet Radio Lights Endpoint
Переглядів 794 роки тому
In this video we will see what the lights on an Endpoint Baseline Ethernet Radio indicate. We will also see what it looks like to have a poor signal quality or a missing or damaged antenna. The radio in the video is installed in the Baseline Radio survey kit plastic enclosure.
Two Wire Troubleshooting
Переглядів 9 тис.4 роки тому
This video is about Two Wire Troubleshooting. How to tell if you have a short, ground fault or a wire break. This video gives a simple approach for finding the location of your two wire fault.
Baseline MV and Flow Wire Installation
Переглядів 1,2 тис.4 роки тому
How to install your master valve, pump start and flow sensor wiring to a Baseline conventional wire controller. R board master valve and flow sensor installation.
Installing an Antenna Cable End
Переглядів 734 роки тому
How to install an N Type male fitting on to LMR400 cable.

КОМЕНТАРІ

  • @noway9610
    @noway9610 Місяць тому

    Good video. I would like to comment on the wire itself, not your methods of testing. In my experience, the twist in the wires and the sheath that surrounds the wire, especially with hunter brand, are engineered and should not be undone or separated because it changes the resistance. 2 wire needs to be viewed as data cable and should not be manipulated.

    • @theirrigationguy700
      @theirrigationguy700 2 дні тому

      Great comment on wire. Hunter ID wire is a twisted pair and is required by the manufacturer (Hunter) to allow for proper communications. Most other brands of two wire use parallel communcation wire. There are general tin coated copper wire. See Paige 7072D two wire cable.

  • @biggus6633
    @biggus6633 8 місяців тому

    Awesome video! Care to share how you made your trouble shooting setup?

  • @urbanirrigation
    @urbanirrigation Рік тому

    thanks for making the best video , that help me troubleshoot short circuit , wire broken and grounded, which are the mains issues in most 2 wire system

  • @lossantos3077
    @lossantos3077 2 роки тому

    Pretty simple thanks for the info.

  • @kruzchronicles9358
    @kruzchronicles9358 2 роки тому

    Thanks for everything you do

  • @terria7631
    @terria7631 2 роки тому

    If I disconnect my decoder from my 3 valves, what impact does it have on the operation of the central controller?

    • @theirrigationguy700
      @theirrigationguy700 2 дні тому

      If a valve is not connected to a decoder on a decoder based controller the valve will not be able to turn on. In event that a solenoid is wired directly to the two wire path you will get a short.

  • @benkrauz725
    @benkrauz725 2 роки тому

    Thank you for videos like this. I've been out of irrigation for 10 years and now I'm back in and all this 2 wire stuff is new to me

  • @tedmoreno4170
    @tedmoreno4170 3 роки тому

    Now do looped 2 wire. Good basic troubleshooting video.

  • @RogerMcCoy1
    @RogerMcCoy1 3 роки тому

    I would love to see a video on using the clamp VOM to find a bad splice (high resistance) in a closed-loop hidden dog fence. A dog fence starts out as two wires at the wall-mounted transmitter but splits into a loop after exiting the garage wall. I can track down a bad splice using a standard VOM by dividing the yard in half, then quarter, then eighth, etc..., I can find a clean cut or break with a line tracing tool and toner. Easy job. But the bad splices make me pull out my hair. Can you show how to do this?

  • @rulycarrillo3161
    @rulycarrillo3161 3 роки тому

    Hi. I have over curent . in the timer both cables are 245.8. At valve 9 the number both cables are 09.08 samething like that

  • @crawfordshirley4556
    @crawfordshirley4556 3 роки тому

    Way to go irrigation guy. Looks like that’ll hold it through the season

    • @theirrigationguy700
      @theirrigationguy700 3 роки тому

      Thanks it was a fun little project the took care of a real need. Its amazing what you can do with stuff that's just laying around.

  • @tukulitosacayama4116
    @tukulitosacayama4116 4 роки тому

    great material, could you make a video wiring from the transformer all the way dawn to the INT board?

  • @brandonsokol7516
    @brandonsokol7516 4 роки тому

    Very good content. Irrigation ninja!

    • @theirrigationguy700
      @theirrigationguy700 4 роки тому

      Thanks. Let me know what other content you would like in future videos

  • @brianyoung6745
    @brianyoung6745 4 роки тому

    Very helpful, Irrigation Guy! Keep em coming!

  • @brianyoung6745
    @brianyoung6745 4 роки тому

    Nice Job, Irrigation Guy!

  • @tracyshields8781
    @tracyshields8781 4 роки тому

    Great stuff! Looking forward to seeing more