QUALITECH ENGINEERING
QUALITECH ENGINEERING
  • 13
  • 13 706
Storage tank jacking floating roof lifting
A closer look at how our floating roof jacking solution works in terms of efficiency, time-saving, safety and environmental responsibility.
This solution, which is compliant with ISO 14001 standards, eliminates the need to flood the tank, as well as the handling of large amounts of polluted water.
without requiring the costly alternative of removing the roof, Having the roof stable at a height of 3.0 meters, enables our client to perform all the necessary alteration and reconstruction to the storage tank shell and bottom.
Переглядів: 446

Відео

Storage Tank jacking Floating roof lifting
Переглядів 3952 роки тому
A closer look at how our floating roof jacking solution works in terms of efficiency, time-saving, safety and environmental responsibility. This solution, which is compliant with ISO 14001 standards, eliminates the need to flood the tank, as well as the handling of large amounts of polluted water. without requiring the costly alternative of removing the roof, Having the roof stable at a height ...
Rim Gap Sealing System
Переглядів 4,2 тис.2 роки тому
Rim Gap Sealing System
Leg Type mechanical Bleeder vent
Переглядів 2,6 тис.2 роки тому
In this storage tank project, our client Comprehensive floating roof integrity scope, includes regularly emission detection survey, with a focus on bleeder vents, which are now considered, as potential unwanted vapor emitters, the same as rim gap seals and support legs. Watch this short video on our in-service "leg type mechanical Bleeder vent" upgrading solution.
Above ground storage tank - Improving bottom integrity
Переглядів 6232 роки тому
Aboveground storage tanks apply high bearing pressures on foundation soils. This may result in excessive total and differential settlement and edge stability performance issues, Welded floors may begin to tear or crack under the imposed loads, and corrosion or metal failure may take place beneath the floor. Qualitech tank jacking solution, allowed the tank owner, to begin reconstructing the tan...
Shell settlement evaluation In accordance with API 653
Переглядів 3,5 тис.2 роки тому
Most of the petroleum above ground storage tanks usual support configuration is by soil compaction, ringwall, concrete slab or pile cap supported foundation. The failure of these tanks can result in serious environmental and life-threatening issues, not to mention financial losses. Shell settlement evaluation, is therefore, an integral and important component, of any "in service external inspec...
API 653 STORAGE TANK IN SERVICE EXTERNAL INSPECTION
Переглядів 1,2 тис.2 роки тому
Inspecting aboveground storage tanks regularly is essential for detecting potential failures that could damage facilities, personnel, or the environment. API 653 inspection code and industry standards, both state that storage tanks should be inspected, every five years, or one quarter of the shell remaining life, the lower of them, for in-service external inspection.
vapor tight sealing system for covered externl floating roof
Переглядів 2122 роки тому
Meeting the latest environmental standards and compiling the highest safety standards, are our client's requirements, in this 50m storage tank project. Learn more about our BlueSky sealing system solution for external floating roof storage tank.
Storage tank lifting
Переглядів 832 роки тому
The tank jacking technology is now widely accepted, and it complies with all industry codes and standards. The 36m. diameter storage tank was raised 60cm. while keeping the original tank volume. By avoiding the "letter box" configuration, our tank jacking solution keeps the original design of the shell to the bottom.
Qualitech BlueSky Primary and secondary seal system
Переглядів 712 роки тому
An external floating roof's primary rim seal acts as the first barrier against emission in the rim area. Furthermore, it is a safety device that reduces the risk of combustible vapors in this area. Secondary seal designed to effectively prevent rim fires, Protect the stored product from contamination and extend the life of the primary seal. It is therefore extremely important to design and asse...
Guided wave testing
Переглядів 352 роки тому
Inspections of piping systems can be challenging due to their often-unconventional shapes and locations. Equipped with the latest technology in collaboration with NDT Global Services Ltd. inspection is carried out by highly experienced level 2 and Level 3 engineers. Watch our progress in this substantial project.
Blue sky by Qualitech
Переглядів 482 роки тому
Analogy of our Storage tank Engineering evaluations and service with our concern to our children as parents. Our Blue Sky Concept support our Sustainability vision and our 0% emission standard.

КОМЕНТАРІ

  • @miguelurteaga8166
    @miguelurteaga8166 5 місяців тому

    Hello greetings from Peru. Could someone help me with information. How can I repair the concrete base of a steel storage tank? Consider: The tank is already built. What is required is to repair or change concrete bases.

  • @mehmetyilmaz3615
    @mehmetyilmaz3615 5 місяців тому

    Süper Dizany. HAM Petrol tankları olmazsa olmazı bir çok kez taahhüt lerde bu uygulamada bulundum ve bakım işlerinde

  • @opalrisner7007
    @opalrisner7007 7 місяців тому

    Who else is installing a seal on a tank at work ?

  • @alfredoparra-vs1ef
    @alfredoparra-vs1ef 9 місяців тому

    Great video

  • @vijithv7012
    @vijithv7012 Рік тому

    Can you please share the method of statement

  • @qualitechengineering1717
    @qualitechengineering1717 2 роки тому

    For more information visit us at www.qualitech.site

  • @motimaor5045
    @motimaor5045 2 роки тому

    Highly recommend