Complete Water Solutions
Complete Water Solutions
  • 148
  • 234 257
Membrane Cleaning Pro - Professional Membrane Cleaning
Membrane Cleaning Pro - Your Offsite RO Membrane Cleaning Team. Membrane Cleaning Pro can help with all your membrane cleaning needs.
www.membranecleaningpro.com
Membrane Cleaning Pro - does offer onsite services too through our parent team Complete Water Solutions.
Переглядів: 136

Відео

How Reverse Osmosis (RO) Works - How Reverse Osmosis (RO) Membranes Assembled - What is RO
Переглядів 14 тис.Рік тому
How Reverse Osmosis Works By Complete Water Solutions Need Help With Your RO System Contact Complete Water Solutions bit.ly/3h3a6hN In this video, we will explain how reverse osmosis works, a water purification process that removes contaminants from water by forcing it through a semipermeable membrane. What is reverse osmosis? Reverse osmosis is a process in which water is forced through a semi...
Osmonics 45CHF RO System Repairs, Membranes & Upgrade
Переглядів 262Рік тому
Complete Water Solutions recently upgraded this Osmonics 45CHF Reverse Osmosis System for a Manufacture In California. Both RO Systems were manufactured in the 1980's but were in great condition. A new RO system would have been twice as much money along with a 14-18 week lead time. The existing Osmonics RO Controller was obsolete and no longer functioning. Complete Water Solutions provided a dr...
Complete Water Solutions 10 Years In Business - Thank You
Переглядів 60Рік тому
We wanted to take a moment to thank all of our customers. We appreciate all the support and it means a lot to everyone at Complete Water Solutions and our families. Thank you for your business!
Water Softener Resin Testing - How To Know If Your Resin Is Good
Переглядів 6 тис.Рік тому
Complete Water Solutions video topic today is how to pull a resin sample to send in for testing. We also discuss the reasons why you might want to test your resin. Whether you have a water softener or demineralizer (Deionization System) you may want to test your resin to see how its performing. Need Resin? Complete Water Solutions carries many types of resin from, cation, anion, select ion resi...
RO Membrane Housing End Cap Removal (Industrial Reverse Osmosis) - Complete Water Solutions
Переглядів 5 тис.Рік тому
In This Video Nathan From Complete Water Solutions provides insight and directions on how to remove a Industrial Reverse Osmosis (RO) Housing End Cap and how to properly re-install it. - Need Parts Or Tools bit.ly/3h3a6hN Industrial Reverse Osmosis, RO Systems, Complete Water Solutions, Osmonics RO Systems, Fiberglass RO Housing, 8" RO Housing, 8" RO Fiberglass Membrane Housing, WaveCyber Housi...
How Much Salt Should My Softener Use - Salt Reduction Water Softeners
Переглядів 6562 роки тому
In this video CWS takes a look at how much salt a water softener will use. Also we look at some ways to save salt and reduce chlorides. We discuss - Water Softener Brine Study - Water Softener Brine Reclaim - Salt Saving Water Softener Resin (SST-60) - Water Softener Hardness Monitors - Water Reduction - How Chlorides And Salt Affect The Environment Learn More About The Tools We Use & The Free ...
Osmonics E8-57K-ECN Upgrading RO System Controller
Переглядів 2752 роки тому
In this video Complete Water Solutions upgraded an old Osmonics E8-57K RO System Controller. The old controllers were original from 1999 and consisted of the Lakewood 2450 RO Controller and Allen Bradley 1000 Micrologix Series PLC. Both of those have been obsolete for some time now. Complete Water Solutions provides a upgrade kit for the E8 Reverse Osmosis (RO) System. The upgrade kit for the O...
Osmonics Pro-100 & Pro-150 Reverse Osmosis (RO) Membrane Housing Replacement - Manuals & Drawings
Переглядів 3512 роки тому
In this video we show cased replacing some Reverse Osmosis Fiberglass Housings on a Pro-100-NA and Pro-150-NA Reverse Osmosis System. The housings that were replaced were wave cyber 8" Reverse Osmosis Housings (RO Housings). The job entailed replacing (6) Housings Some of the housings were longer than others. Things to take into consideration when replacing these housings: 1.) Grooved Clamps - ...
Reverse Osmosis Troubleshooting (LT4 RO System) - Common RO Problems - RO Troubleshooting Guide
Переглядів 1,6 тис.3 роки тому
In this video we cover reverse osmosis (RO) troubleshooting centered around the LT4 Reverse Osmosis System. This new RO System has a lot of similarities to the E4 RO System. This video shows the upgraded PLC Package which allows you to really narrow down the reason your RO system may be having problems. Additional RO Troubleshooting Videos - bit.ly/3alGQiO LT4 Reverse Osmosis Manuals - bit.ly/3...
How To Install 4" (4040) Reverse Osmosis (RO) Membranes 4" / LT4 RO / E4 RO
Переглядів 3,8 тис.3 роки тому
In this video we walk through how to change the pre filter on the RO System and how to change the RO Membranes on a LT4 / Fiberglass RO Housing Membrane Change. Manuals for the RO Systems & Documentation is listed below. RO Membranes bit.ly/3h6WUJ5 RO Daily Log bit.ly/3DRqBHS RO Pre Filters bit.ly/3DOAFkJ RO Start Up Sheet bit.ly/2XIGBv3 LT4 RO Maintenance Manual bit.ly/3kGoSNS This video cover...
How To Change RO Membranes - Osmonics/GE E4 Reverse Osmosis (RO) - How To Install RO Membranes
Переглядів 11 тис.3 роки тому
In this video we cover how to change Reverse Osmosis (RO) Membranes in a Osmonics / GE Water E4 RO System. We cover some step by step basics and show the process. RO Daily Log Document - bit.ly/3DRqBHS RO Start Up Document - bit.ly/3jOrlWc RO Membrane - bit.ly/3h6WUJ5 Parts, Filters & More - bit.ly/2Ynfnua Osmonics / GE Water E4 Manual - bit.ly/3l3Xjx7 Other RO Membrane Change Out Video - bit.l...
What To Check On My Reverse Osmosis System (RO System) Daily Check List E4 & LT4
Переглядів 1 тис.3 роки тому
Complete Water Solutions covers what you should be checking daily on your Reverse Osmosis System (RO System) Things covered in this video are water testing and why it is important. If left unchecked you could damage your membranes. Also covered is changing your RO Pre Filter and why its important. FREE RO DAILY LOG SHEET - bit.ly/3DRqBHS Shopping For Supplies - bit.ly/2Ynfnua RO Pre Filters - b...
Osmonics / GE Water E4 Reverse Osmosis (RO System) Maintenance & Daily Checks
Переглядів 1,5 тис.3 роки тому
Complete Water Solutions covers what you should be checking daily on your Osmonics / GE Water E4 Reverse Osmosis System (RO System). We cover water testing, flows, pressures as well as changing of the pre filter. FREE RO DAILY LOG SHEET - bit.ly/3DRqBHS Shopping For Supplies - bit.ly/2Ynfnua RO Pre Filters - bit.ly/3DOAFkJ How Long Do Membranes Last - bit.ly/2YAMXxb What RO Cleaning Chemicals S...
Habitat For Humanity - Kenosha & Complete Water Solutions
Переглядів 543 роки тому
Complete Water Solutions had an opportunity to volunteer @ Habitat For Humanity - Kenosha. We were honored to have the opportunity to work on a home for the local community. We learned a lot about Habitat For Humanity and their mission. To Learn More About Habitat For Humanity or To Donate bit.ly/3yNwFwY
Osmonics E4 Reverse Osmosis (RO) & New LT4 Reverse Osmosis (RO)
Переглядів 3503 роки тому
Osmonics E4 Reverse Osmosis (RO) & New LT4 Reverse Osmosis (RO)
Happy Fathers Day - From Complete Water Solutions
Переглядів 563 роки тому
Happy Fathers Day - From Complete Water Solutions
Complete Water Solutions Sea Water Reverse Osmosis (RO) Service
Переглядів 1033 роки тому
Complete Water Solutions Sea Water Reverse Osmosis (RO) Service
Tonkaflo Pump Drawings & Tonkaflo Pump Manuals - Watch Before Taking Apart
Переглядів 1,1 тис.3 роки тому
Tonkaflo Pump Drawings & Tonkaflo Pump Manuals - Watch Before Taking Apart
Tonkaflo Pump Oil Maintenance & Lead Times
Переглядів 7153 роки тому
Tonkaflo Pump Oil Maintenance & Lead Times
Tonkaflo Pumps Built To Order - Can I Get A Tonkaflo Pump Today?
Переглядів 2343 роки тому
Tonkaflo Pumps Built To Order - Can I Get A Tonkaflo Pump Today?
Fleck 3900 Side Mount Softener System
Переглядів 6733 роки тому
Fleck 3900 Side Mount Softener System
Industrial Water Softener Replacement 1200 GPM Softener System
Переглядів 2,2 тис.3 роки тому
Industrial Water Softener Replacement 1200 GPM Softener System
Continuous Electronic Deionization (CEDI) - What Is Inside CEDI
Переглядів 16 тис.3 роки тому
Continuous Electronic Deionization (CEDI) - What Is Inside CEDI
Osmonics Beverage Nano Filtration (NF) 1233033
Переглядів 1 тис.3 роки тому
Osmonics Beverage Nano Filtration (NF) 1233033
Is My Softener Using To Much Salt? - Industrial Softener Review & Resin Replacement
Переглядів 1893 роки тому
Is My Softener Using To Much Salt? - Industrial Softener Review & Resin Replacement
Osmonics Reverse Osmosis E8 Lakewood Controller Replacement
Переглядів 2303 роки тому
Osmonics Reverse Osmosis E8 Lakewood Controller Replacement
Osmonics E8 Lakewood 2450 Controller Upgrade
Переглядів 813 роки тому
Osmonics E8 Lakewood 2450 Controller Upgrade
Fleck 3150 Carbon Filter - Carbon Replacement - Carbon Re-Bed
Переглядів 5413 роки тому
Fleck 3150 Carbon Filter - Carbon Replacement - Carbon Re-Bed
How Water Softener Resin Got Inside A Reverse Osmosis (RO) System Osmonics Reverse Osmosis
Переглядів 1,2 тис.3 роки тому
How Water Softener Resin Got Inside A Reverse Osmosis (RO) System Osmonics Reverse Osmosis

КОМЕНТАРІ

  • @earlfriend
    @earlfriend 23 дні тому

    I’ve been looking for some reference videos for friendly education use and I am so thankful for this! Most of the more popular videos are pretty awful

  • @Бажен_Яров
    @Бажен_Яров Місяць тому

    Отличное объяснение! Спасибо.

  • @thuanvu2909
    @thuanvu2909 2 місяці тому

    Please send me Price and contact with you. Many Thanks

  • @prasunmondal9679
    @prasunmondal9679 4 місяці тому

    Price please

  • @hiburananakku
    @hiburananakku 4 місяці тому

    i have problem that,, sea water come to product line even thought HP pump running with low pressure. do you have experinced about it?

    • @nateolszak1078
      @nateolszak1078 4 місяці тому

      Bad seal bad membranes or control issue. Unfortunately couldn't tell you with out reviewing the system.

  • @hiburananakku
    @hiburananakku 4 місяці тому

    thanks a lot

  • @hiburananakku
    @hiburananakku 4 місяці тому

    thanks for these video. do you provide any sharing for troubleshoot?

    • @nateolszak1078
      @nateolszak1078 4 місяці тому

      we have a whole series for troubleshooting on youtube - ua-cam.com/video/iq5GnC2y-w0/v-deo.html

  • @mikef.6216
    @mikef.6216 4 місяці тому

    Thanks bro.

  • @JorgeMacedo1965
    @JorgeMacedo1965 4 місяці тому

    I changed lots of RO membranes but never with a hat.

  • @godfreymathosa8194
    @godfreymathosa8194 5 місяців тому

    Thank you

  • @dmitrijshodacenko1410
    @dmitrijshodacenko1410 6 місяців тому

    is it safety hat ??? LOL ....

  • @pacae911
    @pacae911 6 місяців тому

    How long I need to change the resin ? 3 day ? 3 weeks ? 3 months 3 years ?

    • @LiamHetland
      @LiamHetland 3 місяці тому

      Ideally, never. However, most water softeners say that they have a life span of about 30 years, and this is mostly limited because of the resin. As long as you take proper care of your softener, you shouldn't really need to replace your resin and it can outlast more than 30 years. Taking care of it includes things like making sure it always is full of salt and that it doesn't completely run out. Make sure you wash your system every 4 months or so, and don't have a lot of iron or other solids enter Your system (you can do this by installing a water filter before your softener). However, if your softener has been mistreated and/or is older, it may be a good idea to check the quality of the resin. If it is not good, then you'll likely need to replace it.

  • @autoroyal2751
    @autoroyal2751 6 місяців тому

    fuck your music. junk company

  • @HVASEA
    @HVASEA 6 місяців тому

    answer @ :34

  • @FedorVinogradovGoogle
    @FedorVinogradovGoogle 6 місяців тому

    This is the best explanation video so far, but even there is hard to catch how water enters permeate tube

    • @nateolszak1078
      @nateolszak1078 6 місяців тому

      There is a slit in the permeate tube and it travels through that.

    • @erdem--
      @erdem-- 4 місяці тому

      it is like a bag, a pouch. clean water diffuses into pouch and exits from the tube.

    • @nateolszak1078
      @nateolszak1078 4 місяці тому

      @@erdem-- a bag filter only has one inlet and one outlet. A RO Membrane has one inlet and (2) Outlets - 1 concentrate (waste) and 1 permeate (RO Water)

    • @erdem--
      @erdem-- 4 місяці тому

      @@nateolszak1078 RO filte is shaped like a bag. The water diffuses into the bag. thereby It has 2 outputs. If the water did diffuse out of the bag, it would be a 1 output filter.

  • @Paul-q3m7k
    @Paul-q3m7k 6 місяців тому

    1-2 years is complete bs . I’ve got water that has a tds of 389 . After 5 years it’s still producing water below 20 ppm at good flow rate

    • @nateolszak1078
      @nateolszak1078 6 місяців тому

      Actually that's not good compared to ro manufacture specifications. You should be closer to 3 to maybe 7 tds. So unless your that range you may not be. It also depends on pretreatment and how hard you run your ro. I also mention that in the video.

  • @bonnierapoo8316
    @bonnierapoo8316 7 місяців тому

    I have an RO system that is not producing enough flow on the concentrate side, 1 month after changing the membranes. What could be the problem?

  • @gial8862
    @gial8862 7 місяців тому

    That has to be the most ridiculous tool ive ever seen

    • @nateolszak1078
      @nateolszak1078 7 місяців тому

      It works and we have removed thousands of membranes out. When your dealing with 6 long or 7 long housings and have 20+ housings to do it makes life alot easier.

  • @JamwelGicharu
    @JamwelGicharu 9 місяців тому

    Hello sir, your insightful videos are a great resource.thank you We recently did a cip on our Ro but the membranes are not giving all water as product and no reject water.in short not working at all. We used caustic soda and citric acid for cip. What could have gone wrong. Iam Jamwel from malindi kenya. Appreciate alot

    • @completewater
      @completewater 9 місяців тому

      Good Evening, there could be multiple reasons. Everything from mechanical, to waiting to long to clean, to no using the right cleaners. I would visually inspect the flow meters and make sure they are operating correctly and valves are functioning properly. Then remove the end caps to identify what kind of scale or bio you might have. We have seen customers scale the membranes to the point where no flow was registering. If this happens then you will need to determine what the cause was or is. Example antiscalant was not working or softener failed. Etc.

  • @KevinMcLaughlin-o3w
    @KevinMcLaughlin-o3w 10 місяців тому

    Validation Engineer, CQV clean utilities projects. Pretty cool seeing the inside disassembled, really adds to the P&ID.

    • @completewater
      @completewater 10 місяців тому

      Thank you for the feed back - much appreciated.

  • @MaheshMahi-sl2rw
    @MaheshMahi-sl2rw Рік тому

    Can tell me how can decide the flow while doing cip??

    • @nateolszak1078
      @nateolszak1078 Рік тому

      Depends on membranes, how many, the machine size, the chemicals your using and what your trying to clean. My recommendation is to look at the membrane manufacture data sheet along with the cleaners your using.

    • @MaheshMahi-sl2rw
      @MaheshMahi-sl2rw Рік тому

      @@nateolszak1078 my plant unit have 181 vessels and each vessel have 7 membranes

  • @PrémicesKasamba
    @PrémicesKasamba Рік тому

    Hello i hope you are well,can you give me the names of the constituent element of CEDI please

    • @completewater
      @completewater Рік тому

      Due to legal reasons we are not able to identify manufacture.

  • @axomatic123
    @axomatic123 Рік тому

    Do you do the remanufacturing EDI ionpure?

    • @completewater
      @completewater Рік тому

      we personally do not, we typically send to factory.

  • @IgnacioColomboLeón
    @IgnacioColomboLeón Рік тому

    Hello! What are the lifespans of the membranes showcased when used for sea water desalination?

  • @hazemturk6337
    @hazemturk6337 Рік тому

    I want contact with you by WhatsApp

  • @petetasker2776
    @petetasker2776 Рік тому

    Please send me a cowboy hard hat !

  • @jonezy6056
    @jonezy6056 Рік тому

    Thanks Nathan, we've got a commercial system with qty 12 4"x40" membranes (3:2:2:2:1:1:1 array) that were just replaced less than a month ago but are already seeing significant flux loss and pressure drop (210 psi down to 75 psi, currently flowing ~11gpm permeate, 7 gpm concentrate after acid cleaning). Visual inspection doesn't show obvious significant debris or biomass in membrane feed spacer. Can hardness scaling cause pressure drop as well?

    • @nateolszak1078
      @nateolszak1078 Рік тому

      There are a lot of items that can cause DP and Flow issues. Organic, Bio, Scale, Silt, Temp. You may not necessarily see it when opening up the end cap. You may see it when cleaning the membrane. Using a good cleaner is a good start but also making sure the pre-treatment is proper can help.

    • @jonezy6056
      @jonezy6056 Рік тому

      @@nateolszak1078 thank you! Antiscalant dosing was verified to be appropriate, but the carbon tanks are not sending a shutdown signal so RO may be running during a backwash. Prefilter looks good however, and usually this gets clogged up when I've seen this issue on other systems

    • @nateolszak1078
      @nateolszak1078 Рік тому

      @jonezy6056 Water analysis, including PSA and SDI, may help you identify the issue or at least start narrowing down. Could also run into issues if the RO sits for long periods with out use.

  • @dasarinaveenkumar9557
    @dasarinaveenkumar9557 Рік тому

    Great video. Thanks for the information. Can we service EDI ?

    • @nateolszak1078
      @nateolszak1078 Рік тому

      EDI Systems can be services, typical services may include, stack replacement, factory rebuilds, cleaning and sanitizing

  • @Infidel67
    @Infidel67 Рік тому

    After changing the Membranes and pre filter on the E4 just as before I have very low output on water first I had 2gpm, after filter change it went to 3gpm but 2 weeks later it's down to 1 gpm We bought the unit used, but I don't know what else it could be? All my incoming pressure is good. could it be the centrifugal pump?

    • @completewater
      @completewater Рік тому

      Could be the pump but typically you would find that right away. You could check the discharge screen of the pump. If your recovering too high you could be scaling your membranes, Also if you have no pre-treatment or are having issues with your pre-treatment you can loose output. If you have the wrong membranes you may have lower output as well. Depending on water temp.

    • @Infidel67
      @Infidel67 Рік тому

      @@completewater We have a large Carbon cartridge before water incoming.

    • @completewater
      @completewater Рік тому

      @@Infidel67 You will need more than that most likely. Here is a blog post we did regarding "What Else Do I need With My RO" complete-water.com/blog/what-else-do-i-need-with-my-ro-system

  • @bigal8725
    @bigal8725 Рік тому

    We have packs going bad. Our pH on our water is 8.6-9.0 coming out of our RO. We've had intermittent hard water issues from our softeners switching back. My question is can the granules inside loaded with magnesium/calcium/iron/etc. be saved? I would think trying to recharge them with an acid recirculation might do the trick.

    • @nateolszak1078
      @nateolszak1078 Рік тому

      Hello, So my recommendation is to review the manual of the CEDI / EDI Stack Manufacture. They will have procedures for cleaning the Stacks. Highly recommend following it step by step as you can cause irreversible damage.

  • @Infidel67
    @Infidel67 Рік тому

    We got the GE E4, is it possible to upgrade the manual reading OP to a digital like this one?

    • @nateolszak1078
      @nateolszak1078 Рік тому

      Unfortunately there is not a "Upgrade" kit to go to a PLC version. They have actually discontinued the E4 Model and have moved over to the LT4. The RO in this video with the HMI is the upgraded version of the LT4. The basic LT4 is very similar to the E4 RO.

  • @donotcare330
    @donotcare330 Рік тому

    Great videos. I have a user request video here. Could you show us if a single 4x40 membrane under 300 psi. If it will fill a 40 gallon well pressure tank to 60 psi? I am REALLY curious! Thanks again for posting and always enjoy your videos!

    • @completewater
      @completewater Рік тому

      Hi Rick, just based on past experience yes it can. However you need the right piping connections, and equipment. Certain design criteria should be in place for this. I have seen some systems operate this way. (Smaller commercial). I will see what we can do to cover that topic at some time this year.

    • @donotcare330
      @donotcare330 Рік тому

      @@completewater That would be awesome. I am curious if a single 4x40 at 300 PSI, such as a Grundfos feeiding into the vessel, would push water through the membrane and into a pressure bladder tank without a post permeat pump. Your videos are highly educational and are shaping the water industry in a positive manner!

  • @xtremepowerwashing1815
    @xtremepowerwashing1815 Рік тому

    So the seal on the RO membrane goes on the same side where water is entering correct?

  • @ABDELBASTKARBAL
    @ABDELBASTKARBAL Рік тому

    I can know the price of a small elementary cell, the production of water treated desalination per minute

    • @completewater
      @completewater Рік тому

      Hello please email us info@complete-water.com we can provide a price and help you select the right edi

  • @abdel8488
    @abdel8488 Рік тому

    Hello, a good video, if you can make a video for us for a simple amateur-made cell, the materials constituting

    • @nateolszak1078
      @nateolszak1078 Рік тому

      Unfortunately we will not be able to disclose all the specific materials inside as most of them are protected under patent laws.

  • @quyenluong1901
    @quyenluong1901 2 роки тому

    I don't know what material the 2 electrodes at the top of the plastic plate are without being electrolyzed

    • @nateolszak1078
      @nateolszak1078 2 роки тому

      You might be able to reference the manual to get an idea of what side of the DC current it is

  • @gtavc007
    @gtavc007 2 роки тому

    Hi thanks for the videos they are really informative, i got a question regarding this unit, is this a two stage RO system? also would it work with 1000+ ppm inlet water?

    • @completewater
      @completewater 2 роки тому

      Hello, I am not sure what you mean by 2 stage. Its a 2-2-2 Array but single pass. I am not sure what you also mean by 1000+ ppm water. What is 1000 ppm = to TDS? You may have to get an analysis done to verify what is in the water. We have a free E-Book regarding what you need for your RO System. complete-water.com/blog/5-things-you-should-know-before-buying-your-next-ro-free-quick-read It will work on 1,000 TDS Water but you will want to know what is in your water to make sure you have the right pre-treatment.

  • @Taniamustafa
    @Taniamustafa 2 роки тому

    I want to know how you fix anion and cation in edi. and which type of anion exchange membrane and cation exchange membrane.

    • @nateolszak1078
      @nateolszak1078 2 роки тому

      Unfortunately that is confidential information. They do not share that with us.

  • @bannisterjames2845
    @bannisterjames2845 2 роки тому

    The music is too high.

    • @completewater
      @completewater 2 роки тому

      Thank you for the feed back. Some day we will get around to shooting another video with no music

  • @sharifskijr.1257
    @sharifskijr.1257 2 роки тому

    Awesome

  • @ReallyNo.01
    @ReallyNo.01 2 роки тому

    Please demonstrate…

    • @completewater
      @completewater 2 роки тому

      We are working on that video for standard ro system. Written step by step procedures. The link is located in the description.

  • @sharifskijr.1257
    @sharifskijr.1257 2 роки тому

    Much appreciated!

  • @robinsonvarghese9119
    @robinsonvarghese9119 2 роки тому

    Dp 1.67 bar pressure 3.5 bar

    • @completewater
      @completewater 2 роки тому

      There can be many reasons why DP is high, It can be water quality, flux ratio, organic fouling, too much waste, membranes installed wrong, water temp, lots of reasons why DP is high. The E4 and LT4 RO Systems do not have pressure gauges between stages so not sure what system you have, or how your running. You can find trouble shooting information on our website that might help you go through some things. complete-water.com/resources/reverse-osmosis-troubleshooting-guide

    • @robinsonvarghese9119
      @robinsonvarghese9119 2 роки тому

      Veolia sir

    • @robinsonvarghese9119
      @robinsonvarghese9119 2 роки тому

      Level 3 comes high tds Stage 1 = 15 Stage 2= 35 Stage 3= 250 Permit tds = 40

    • @completewater
      @completewater 2 роки тому

      @@robinsonvarghese9119 could be water quality or bad permeate o-ring, or bad innerconnector o-ring, you could be recovering too high.

    • @completewater
      @completewater 2 роки тому

      @@robinsonvarghese9119 I would potentially contact them to see if they can point you in the right direction. Unfortunately we dont have enough data to help you. We do offer field services where our technician can come out and help. If you would like to discuss a field service tech to come out you can email your request to info@complete-water.com

  • @robinsonvarghese9119
    @robinsonvarghese9119 2 роки тому

    But stage 1 dp very high Why sir? Please discuss

  • @robinsonvarghese9119
    @robinsonvarghese9119 2 роки тому

    Sir we are charged membrane

  • @faycalali1759
    @faycalali1759 2 роки тому

    hello team complete water solutions i have one question about membrane. what is the limit of temperature to maintain our membrane good condition. if my water in almost concert by the salt at 50 per and my temperature is going around 50 degree. what they will infect in my membrane.

    • @completewater
      @completewater 2 роки тому

      Hello, that depends on the membrane. Every manufacture has a limit as to temps for membranes.

  • @ignaciogrosso6942
    @ignaciogrosso6942 2 роки тому

    Amazing proyect! I would like to know the RO feed conductivity.

    • @completewater
      @completewater 2 роки тому

      Hi Ignacio it was between 800-900 Microsiemens depending on what wells they are pulling from.

    • @ignaciogrosso6942
      @ignaciogrosso6942 2 роки тому

      @@completewater Thanks for the reply. I work at Biraden Water Solutions, also a Water Solutions company from Uruguay, and I have a very similar proyect. We are going to generate DI Water (<2 microS/cm) from 1400 microS/cm well water, with microfiltration, RO (PROflex LT4-3) and a cation resin tank and anion resin tank. We are currently waiting the RO to arrives to Uruguay from the States, so can't wait to see the plant in operation!

    • @completewater
      @completewater 2 роки тому

      @@ignaciogrosso6942 That sounds like a fun project - send me some pictures once its done would like to see it info@complete-water.com

  • @robinsonvarghese9119
    @robinsonvarghese9119 2 роки тому

    Hi sir . I have a question Ro permit pressure high problem why causes?

    • @nateolszak1078
      @nateolszak1078 2 роки тому

      You have something post ro restricting the permeate flow or you have a bad high permeate pressure switch. (2 most likely causes)

    • @robinsonvarghese9119
      @robinsonvarghese9119 2 роки тому

      @@nateolszak1078 yes sir we have 0.2 micron

    • @robinsonvarghese9119
      @robinsonvarghese9119 2 роки тому

      Already blocked 0.2 micron because tds high raw water tds 460 .permit tds 320

    • @robinsonvarghese9119
      @robinsonvarghese9119 2 роки тому

      Sir I think some these particles going inside. So is there any chance sir

    • @completewater
      @completewater 2 роки тому

      @@robinsonvarghese9119 you might have to replace membranes, clean or check seals/orings. Typically membranes remove 97-99% of the incoming TDS. It sounds like you have a problem there.

  • @woodsyguy2753
    @woodsyguy2753 2 роки тому

    What a stupid hard hat. Fix it.

  • @roniesangalan8125
    @roniesangalan8125 2 роки тому

    Hi. I would like to ask for any recommendation.. our EDI have 4 stacks. 2 of them is not functioning as the amperage is zero. already changed the rectifiers but no improvement. Is the problem within the internals of the stack? thanks

    • @completewater
      @completewater 2 роки тому

      I would check the controls if its displaying zero and you have no power at the stack then there is something going on with the controls.