HVAChiller VRV Repair
Philippines
Приєднався 26 жов 2017
HVAC CHiller VRV units
Відео
TVR 6g Trane training Kilowatt meter day2C
Переглядів 9Рік тому
TVR 6g Trane training Kilowatt meter day2C
Pre commissioning secondary Chilled water pump
Переглядів 702 роки тому
Pre commissioning secondary Chilled water pump
CRAC emerson DX system. high pressure transducer
Переглядів 732 роки тому
CRAC emerson DX system. high pressure transducer
HVAC installation of supply air grile and return air grile
Переглядів 402 роки тому
HVAC installation of supply air grile and return air grile
Trane Chiller / rectify leakage and regas.
Переглядів 662 роки тому
Trane Chiller / rectify leakage and regas.
YORK Chiller. assessment and troubleshoot 2-3parts
Переглядів 533 роки тому
YORK Chiller. assessment and troubleshoot 2-3parts
YORK Chiller. assessment and troubleshooting. 3-3parts
Переглядів 293 роки тому
YORK Chiller. assessment and troubleshooting. 3-3parts
YORK Chiller.assessment and troubleshoot 1-3parts
Переглядів 473 роки тому
YORK Chiller.assessment and troubleshoot 1-3parts
Trane Chiller. defective flow switch.
Переглядів 1,9 тис.3 роки тому
Trane Chiller. defective flow switch.
Daikin VRV IV. Replacing Main PCB RXYQ8
Переглядів 1803 роки тому
Daikin VRV IV. Replacing Main PCB RXYQ8
TRANE Chiller compressor oil test CT bank
Переглядів 2773 роки тому
TRANE Chiller compressor oil test CT bank
Daikin VRV IV. how to replace main PCB
Переглядів 1,6 тис.3 роки тому
Daikin VRV IV. how to replace main PCB
Daikin VRV IV. Replacing main PCB RXYQ4
Переглядів 3043 роки тому
Daikin VRV IV. Replacing main PCB RXYQ4
To how much this TRANE cost approximately and where are you based ?
Bro how much this TRANE cost and where are you based ?
To enter the mode, did you say 2.20? Then BS 2 once, then BS 3 two times?
Pj error skyair
This is the most amazing video that I’ve ever seen 😢
Thanks from Australia mate. I was guessing my phase monitor was the faulty piece and didn't think to bridge it the way you did, will grab new monitor. Legend.
Emerson ma warm alarm ka video upload karo na bhai
ua-cam.com/video/KQEh6t7pdCw/v-deo.htmlsi=CYGk3sr6P5bNXmYV
Daikin vrv 4+ suction line making ice... Can you please tell me what us the problem
Boa tarde, eu com dovidar vrv esta apresentar pj 09 oque faço?
Boa tarde, eu com dovidar vrv esta apresentar pj 09 oque faço?
2.5 ton water chiller compressor price pH 3
Hi my Dear I have one problems in seam marque MONTAIRE I switch on after 15 seconds fan supply switch of alarm AFS. CAN YOU HELP ME
Where to contact the hose
You did show the charging port where the hose is connected
How to clear error LC-14? Thanks for the answer
Sir kumusta po, tanung ko lang same tayo nang unit may alarm yung comp #2 UNLOADER ACTIVE check kna yung eev board ok nmn yung transducer ok din. Anu po possible na issue? Salamat
Sorry late reply na busy. Anong unit brand and model number
'Promosm'
bro can i get your number..i want to learn more about how recharge manual &auto VRV 4 RXQ18TAYM
26 hp? 26 ton?
26 HP
Hola, gracias por el video, tengo seis equipos vrv Daikin todos concetados en serie y me.estan presentando ese.error u1-06, mi pregunta es debo invertir las líneas a todos los.seis equipos o debo buscar cuál.es.el equipo que me está presentando la falla? Baje los totalizadores y resetee el sistema pero horas después volvieron a presentar el error u1-06 que debo hacer gracias quedo atento
can you please send me your contact details
Can you please assist me with the password of the model i sent you .
hi, do you still need passwords ?
hello , i have a montair close control unit (model - czxtxt 1005 ES/GL)
How do I run a test on this? Also, how do I reset it in order to add an indoor unit which might had a communication problem when I operated them the first time? In vrv lll there are 2 extra buttons for these functions.
Hi, this error is pj 04 after changing noise filter.
Noise filter is not cause of this issue. The main PCB ensure the setting of dip switch is correct.thanks
Poor info
Chang key tha nahi ho rha
Vrvx
U1-16telme please 🙏
Phase reverse.make sure if powed is ok
LC 30 sar plaass explen sar
You don’t explain why
NOPE!!!
Gud day Sir, mag shut down man yung condenser ko after mga 3min tapos low pressure ang alarm, bakit kaya di nag andar yung conderser "outdoor unit. same unit po sa video mo. salamat po sa solution.
Good day sir.saang bansa po kayo ngayon.low pressure alarm CRAC emerson.hinde talaga mag on yong condenser mo kasi may problema ka sa low pressure. Sulotion paki check ng refrigerant mostly ang mga unit na to ay 410A at 407C. Transducer at low pressure switch ang kadalasang gamit ng unit paki check kung close ang contact nya thru the mainboard.nandyan sa menu niya.sana mag subscrive ka sa channel.
Sir crac unit qatar mai Laga huaa hai sir please replay kigiye
Yes english please.i will answer you
and hoow and wich place i can add oil in trane rtac
Good day.you can add on the top side of oil filter, thete is oil access valve, use oil pump.safe work
hi sir how slove high oil tempreture for rtac 185 and i have rtac130 water flow high temprfeture please help me
Please what is the alarm.
😥 🄿🅁🄾🄼🄾🅂🄼
Video is poor quality not showing the actual video
How to clear U4-01 error?Thanks for the answer
Check outdoor unit if there is power with no alarm.clear if there is.check communication cable between indoor and outdoor
How to clear or reset the error of U4-01?Thanks for the answer
Nice
what the step to clear error E4 01
Sir, good day, can you share how we can have TECHVIEW software? And please share us also the contenuetion on how to bind... Thank you po... Be safe...
Master..how about this eror.PJ-04.FLOORSTANDING 3TONS.Daikin..cant you help me..
Show me the error code. Snap sent it to me
PJ is means mismatch.did you change any PCB ing outdoor unit
trane rtac chiller not york brother
Bai asa ka nga lugar nag hvac? Nice kaayo very helpul salamat
Africa
Please help. When I checked mine is shows ' - ' and error U7-02. How can I fix it
What is the cause of j9 error code
Kaybigan ano Ang sera Kong Ang error I pj-04?
Good morning.nagpalit ba kayo ng PCB ng unit bagp lumabas ang error?
Master outdoor unit inverter PCB mis match
@@hvachillervrvrepair9205 oo sir piro mag on ko nag breaker sir pomotok Naman Ang PCB
@@joefercordova3034okey.next time kapag ganito ang issue kunying ingat.kasi ninsan compressor ang sira. Or invrrter fan pcn or inverter pcb.putok din yong noise filter
Hi please can you help with the full fault code?
Which code
@@hvachillervrvrepair9205 sorry I mean list of mode 2 codes. I'm equally having PJ-09 on my new board. How do I correct that. Please give list of codes and their value