Plumbing electric and heating repairs and installs
Get your hose Spicket ready for winter here it comes
Get your hose Spicket ready for winter here it comes
Переглядів: 8
Відео
Don’t overload your circuits window, air conditioner draw a lot of power and will melt power strips
Переглядів 43Місяць тому
Don’t overload your circuits window, air conditioner draw a lot of power and will melt power strips
Whole house air con capacitor testing
Переглядів 473 місяці тому
Whole house air con capacitor testing
Clean your window ac units every year a vinegar solution is effective as well
Переглядів 5234 місяці тому
Clean your window ac units cut down on big bills
Pex a flows better than pex b for shower fixtures
Переглядів 114 місяці тому
Pex a flows better than pex b for shower fixtures
Happy new year sausage ziti ragu with béchamel sauce
Переглядів 105 місяців тому
Happy new year sausage ziti ragu with béchamel sauce
Noritz combination boiler condensate leak ate manifold
Переглядів 55 місяців тому
Noritz combination boiler condensate leak ate manifold
Ecm variable speed motor and bell thermistor repair
Переглядів 3166 місяців тому
Ecm variable speed motor and bell thermistor repair
Propane buderus lagono boiler propane conversion soot issue
Переглядів 709 місяців тому
Propane buderus lagono boiler propane conversion soot issue
Stake ons and oil burner flame sensors
Переглядів 2011 місяців тому
Stake ons and oil burner flame sensors
Oil fired, boiler with maintaining triple acting aquastat burned up
Переглядів 47Рік тому
Oil fired, boiler with maintaining triple acting aquastat burned up
Delta shower anti scald poor hot water pressure
Переглядів 54Рік тому
Delta shower anti scald poor hot water pressure
2006 mercury optimax 115 no water flow
Переглядів 3,6 тис.Рік тому
2006 mercury optimax 115 no water flow
Our Beckett / Coleman. Has stopped working right. Been stuck in lockout. I finally took a closer look and noticed the screw / nipple in the clean out was leaking small amount. I loosened and tightened and think it stopped. Wondering how am I supposed to clean out the clean out hahah. Also wondering why it’s doing this ? Any advice appreciated
What degrees bushing did u use ?
IF THE WIRE IS 12 /2 ON A 15 AMP BREAKER AND IS WORKING FOR LIGHTS ONLY AND THERES ONLY 8 TO 10 LIGHTS CONECTED TO THAT BREAKER WITH OUT SERVICING ANYTHING ELSE THERE'S NO FIRE HAZARD GET REAL
Receptacles on circuits this is not the only room . Air conditioning units in windows are big draws . These are the facts .
That looks like old 12 nm before the yellow jacket
Looks the same as 14nm back then but you can tell how easy it flexes and the strippers don’t lie either
Why pull new wire, just put it on a 15 amp breaker
As per national electric code you cannot downsize wire in a circuit , the next electrician may put a bigger breaker on if he sees the larger wire in panel
Yeah my 2016 dually just started this after we replaced the drag link and inn/outer tie rods and sway bar end links and front end alignment. Just wondering what it could be. Didn’t have the issue b4 all this was recommended
Ford sets these really close can’t hurt to add a few degrees to stabilize. Things move after 100k too . Mines going well still but it will change alignment
What about the post in the corner.
The GC is addressing it ….
What about when the romex runs through insulation? It cant shed heat in that situation.
The national Electric fire code book states that cable can be run though conduit though walls to protect it . The amp rating is not affected if following code specs
yeah but it sucks for the next plumber who comes out to replace somethint
I mean a plastic tub drain on a fiberglass tub should be there for a while like forever almost . I’m not against plumbers putty if done correctly. But silicone is less call backs for glass tubs
Eehhh, it’s fine.
I mean as long as you de rate the breaker sure
Same thing happened to mine.
They are sending me a new light after filing a warranty claim. Fyi.
They did refund me but I wound up with the arkflex This time
These bushings are great for destroying axle dust seals and inner oil seals
Same exact thing happened to my arkfeld pro. I came here to see if others had the same issue before looking for warranty service, thanks for posting the video!
You’re welcome I did wind up getting the flex and another pro . I should do another video about the lockout
Those inserts are not the amount of caster or camber it has. They provide up to 2 degrees of change depending on how oriented and how much offset different ones provide by moving the upper ball joint geometry. Base caster and camber are based on the front end design. These trucks once had fully threaded bolts, instead of shouldered bolts, that held the track bar to the frame. This resulted in the track bar bracket getting loose at the frame. Your shocks look very old. Take the easy end loose compress it and see if the hydraulics are wore out.
Shocks were done previously with all front end tie rods etc just has some undercoating on them is all cheers
Did it work?
Yes
What degrees did you use ?
@@YoungOzzy432 secret stuff
Hey brother did that work for you? I have replaced a lot of things and still have the shacking
This did work for me , I have not had a death wobble since . But this was basically the last thing that could get replaced in the front end ….
@rms2048 thanks for the reply, my issue was the steering damper was defective, i replaced it and its perfect now
Step away from the spray paint.
We hired an electrician to set up our plug and panel for this. Works great. You can tell when elec is back on if main box is reading numbers. The panel was altered with a safety switch so the main breaker can't be engaged when in use for generator. Although running almost entire house is expensive it is a trade off for convenience and having heat in the cold. Michigan loses power a lot. Dte. So we felt it was a good investment.
Thats great , there are a lot of options for generator installations. Some of that stuff will be in another video. In my opinion it is a great investment for a homeowner. If you have natural gas generator thats a great option but anything is cheaper than a frozen home .
@@rms2048 we upgraded the generator to a 13000 watt dual fuel. Agree. Look forward to your other posts.
Thank you ! If you have something particular your interested in let me know .
@@rms2048 actually I'm having a difficult time finding videos on a way to extend a bathroom vanity light out from the wall do it will hang over a medicine cabinet I have that sticks out about 3-4 inches. We cant recess the cabinet since it's on an outer wall. My only solution is to point the lights up.
Check out vanity light clearance
The longest running one I have is 20 years on my water heater.. held up so far..
I have had success with them , but also had a handful fail .
FYI, the video displays sideways. Even on my iPad, if I tip it to one side, the display is all wrong.
Working on it camera setting