Klima New York, LLC is a leading provider of Variable Refrigerant Flow and Dedicated Outdoor Air Systems (DOAS Systems). We serve New York (Bronx, Brooklyn, Manhattan, Queens, Staten Island), Long Island, and New Jersey.
Klima New York, LLC was established in 2011 primarily as an equipment manufacturers representative. We have continued to expand on these relationships to allow our clients to partner with our firm, utilizing us as their HVAC specialist.
Klima New York, LLC was established in 2011 primarily as an equipment manufacturers representative. We have continued to expand on these relationships to allow our clients to partner with our firm, utilizing us as their HVAC specialist.
How To Install Wire And Set Up Heat Recovery Box || LG Multi V
How To Install Wire And Set Up Heat Recovery Box || LG Multi V
Переглядів: 1 371
Відео
How To Set Up Low Voltage Communication Wire || LG Multi V
Переглядів 2,4 тис.2 роки тому
How To Set Up Low Voltage Communication Wire || LG Multi V
How To Perform The Auto Address || LG Multi V
Переглядів 1,4 тис.2 роки тому
How To Perform The Auto Address || LG Multi V
1:59 wires should be on the left side of screw.
I am trying to connect the invert V outdoor unit to Multi V because the multi V capacity is insufficient. The problem is that Multi V has two communication lines and invert V has one communication line. How to connect multi V and invert V?
Good job thanks 👍
Do have to this if I don’t use the branch box?
Had a burn marks on both the main pcb and power pcb, as well as the inverter pcb. Ever since replacing the boards and attempting to auto address, the outdoor unit cannot find any indoor units or Hr boxes. Any reason why?
What if there are two condensing units master and slave
In this situation, we need to connect the first two terminals on each condenser. Make sure to use an 18-2 shielded, stranded wire for this connection. Also, remember to ground the wire on the main condenser separately from the communication setup for the indoor units.
When he says "this only applies to heat recovery systems" what is he referring to? The entire process of using shielded wires, or landing the ground terminals to indoor units?
Your question is highly appreciated. To ensure proper installation, it is crucial for the installer to use the wire explicitly mentioned in the instructional video, irrespective of the system configuration. It is important to note that the section in the video where our host demonstrates the wiring process for the heat recovery box is solely applicable to systems equipped with heat recovery functionality. If your system does not include a heat recovery box, you may disregard that specific segment of the video.