ABB ACQ580 Push Button Fault Reset
How to wire and program the ACQ580 VFD for push button fault reset.
Переглядів: 364
Відео
How to Configure the ACQ580 for Remote Fault Reset Using Modbus
Переглядів 8442 роки тому
Drives can be set up for automatic reset after a fault when the operating condition returns to normal. Or, drives can be set up for remote fault reset with SCADA via Modbus register. The ACQ580 can easily be setup using the register found in the firmware manual.
Flygt Ready 8 Pump Test
Переглядів 1,6 тис.3 роки тому
Durable, lightweight and easy to service pumps readypumps.com/
Flygt Concertor Intelligent Pump Installation
Переглядів 1,3 тис.3 роки тому
Customer needed a fast turn around equipment upgrade. Existing pumps made lift station unreliable. Hahn Equipment was able to supply and complete installation within 2 days with new Flygt pumps and control panel in stock.
Hahn University: Overflowing Break Tank
Переглядів 3603 роки тому
Field Service in Booster Pump Application
Hahn University: Flygt Concertor Wet Well Cleanout Functionality
Переглядів 5293 роки тому
Flygt intelligent pump cleans wet well after run cycle, removing grease and solids with no clogs. No more vacuum trucks. #clogfree
ACQ580 Beltpress Application
Переглядів 1353 роки тому
Hahn University: Selecting Vector Control Using Drive Composer
Advanced Motor Control & Protection Out of the Box
Переглядів 5003 роки тому
Watch this simple solution for optimizing your electric motors.
Hahn University: Power Logger
Переглядів 654 роки тому
Record and analyze supply power to determine if anomalies occur, such as surge or drop in voltage or amperage.
Hahn University - Godwin Diesel Back-Up Pump - Stormwater Pond application
Переглядів 6424 роки тому
Rain events lead to power surges/outages, which can damage electric pumps and control panels, resulting in dangerous flood conditions on the property. Generators are usually not a solution as the power surging ends up damaging the control panel, resulting in generator running with no pumps pumping. Godwin Diesel back-up is the closest thing to fail safe out there during these conditions. Traile...
Hahn University - JWC Monster Industrial Grinder(s) at correctional institutions
Переглядів 1174 роки тому
Hahn University - JWC Monster Industrial Grinder(s) at correctional institutions
Hahn University JWC Monster Grinder - Zero Waste
Переглядів 1224 роки тому
Demonstration - JWC Monster Grinder(s) supplied and serviced by Hahn Equipment Co., Inc.
Hahn Equipment: City of Tyler Flygt Pump Breakdown 1 of 2
Переглядів 40 тис.4 роки тому
Breakdown Flygt NP3171 35HP Pump for cause of failure & repair estimate
City of Tyler Pump Breakdown 5/8/2020
Переглядів 7 тис.4 роки тому
Hahn University City of Tyler Pump breakdown
Hahn University Site Visit 6-4-2020 - Video 2 - Monster / Paper Plant
Переглядів 1754 роки тому
Hahn University Site Visit 6-4-2020 - Video 2 - Monster / Paper Plant
Hahn University Site Visit - 3 of 3 6-4-2020
Переглядів 1084 роки тому
Hahn University Site Visit - 3 of 3 6-4-2020
Hahn University Site Visit - Monster Grinder - Paper Plant 6-4-2020
Переглядів 874 роки тому
Hahn University Site Visit - Monster Grinder - Paper Plant 6-4-2020
Hahn University: Simulate a fault on ABB ACQ 580
Переглядів 4084 роки тому
Hahn University: Simulate a fault on ABB ACQ 580
Hahn University: How to Wrap Power Cable to Protect Medium Voltage Pump
Переглядів 3614 роки тому
Hahn University: How to Wrap Power Cable to Protect Medium Voltage Pump
Hahn University: Generator Power for Flygt Submersible Pump
Переглядів 1,3 тис.4 роки тому
Hahn University: Generator Power for Flygt Submersible Pump
Hahn University: 3 of 4 Pump Assembly Flygt 3152
Переглядів 10 тис.4 роки тому
Hahn University: 3 of 4 Pump Assembly Flygt 3152
Hahn University: 2 of 4 Pump Assembly Flygt 3152
Переглядів 10 тис.4 роки тому
Hahn University: 2 of 4 Pump Assembly Flygt 3152
Hahn University: 1 of 4 Pump Assembly Flygt 3152
Переглядів 5 тис.4 роки тому
Hahn University: 1 of 4 Pump Assembly Flygt 3152
Hahn University: (2of 2) Godwin Back-up Pump Station
Переглядів 2834 роки тому
Hahn University: (2of 2) Godwin Back-up Pump Station
Hahn University: Godwin Back-Up Pump Station 1 of 2
Переглядів 724 роки тому
Hahn University: Godwin Back-Up Pump Station 1 of 2
Hahn University: Pump Breakdown: Flygt NP3102
Переглядів 31 тис.4 роки тому
Hahn University: Pump Breakdown: Flygt NP3102
28:55 I have also had the FLS (float switch that is supposed to give an alarm for water ingress before the motor is damaged) fail to do it's job so the motor got wet anyway. I don't think I've ever got an alarm from the FLS before it's too late. I think it works in clean water but with waste water, manure etc., it's not effective.
How to use oil please suggest
12:13 vacuum tight
Whats this term you're saying "valute"???
There are 2 marks on the outer stator, lined with the index, will place the handle in the correct positions ❤
Impeller bolt wasn’t Torque
Where is Part 2??
From California here👏🏻 thanks for the video! One of these exact pumps came into the shop today. Used as a guide for disassembly.
gracias por compartir el video.
Sehpada calismayi deneyin yerde hos görünmüyor teknik değil belinizi koruma yok
Belinizi hiç düşünmüyor musunuz teknik çalışın sehpa yapmak cokmu zor yerde iş yapıyorsunuz 😮
Man... This video is cool. Got to face an 8 Flygt pumps maintenance and this video introduced me to them. Tanks!
Very good video, let us have the opportunity to learn
En français
¡Buen video!. He desmontado no hace mucho dos como esas y no es dificil de reparar si se siguen los pasos marcados en el manual que prooporciona Flygt. Muy buenas estas bombas de Flygt. Las reparas con repuestos originales y te despreocupas por muchos años si sabes hacerlo bien. Gracias por compartir el video. Es de gran ayuda a los que nos dedicamos a reparar bombas de residuales.
How do u know if its hard or soft iron impeller from reading code
Neden salmastirayi bozar veya keçeli bozar sebebi nedir
Hola habría una posibilidad de traducir a español gracias
Excelente
So, when are they going to change the battery in their smoke detector???????????????????????????????????????????
From Philippines, I'm Submersible pump mechanic & rewinder. FLYGT a XYLEM Brand.
where is the second part? Please part 2
Hace 20 años que trabajo con bombas flygt de las series 3200, 3201, 3202, 3140, 3127, 3300, 3301 tengo algunos manuales e información técnica, Saludos buen video !
Flygth 280/180 Who dessasembly thanks
Hi guys,thank you for another informative video. Do you repaint your pumps after rebuilt? What paint do you use for the purpose? Thanks
hello, could I see the photo of this pump assembled?
Very good sewage pump
Good video ty
Very good video, let us have the opportunity to learn
Traduction français svp
Workshop etiquette
Veterans
Why not start with inspection plug first ? In addition What is the recommended Preventive maintenance interval? Thirdly cavitation should occur around a circumstance what do you mean when you say it appears on both sides of the impeller?
James, great questions / points, thank you. Yes, agreed, starting with inspection plug is correct. We previously performed this during our breakdown, then went through this pump for the purpose if video. Initial PM inspection is recommended within first year of operation. From thereafter PM inspections are recommended every 12,000 hours or three years, whichever comes first. Great point on condition(s) leading to cavitation. The intent regarding this was for noting evidence of cavitation on both impeller vanes. Much Thanks!
Como logar em 220/380
Winding resistance variation should be less than 10%. FLS has been upgraded and should be replaced. Continuity should be checked first because an open circuit will show high insulation on the megger test. The green behind the tandem mechanical seal is from the main bearing. All O rings should be replaced on assembly. Another cause of cavitation could be the pump inlet to sump floor being too small.
We have cooling water leak from the bottom of the pump. What could be the problem? The pump was removed due to overheating alarm. There was not water left in the jacket. After adding coolant it simply drained from the bottom of the pump.
This is not official diagnosis, but sounds like a seal fail. Can you please send a picture of data plate?
It is 3153.181. Could you please point me which seal might be the problem? Part number would help. Thanks. By the way your videos are excellent and very helpful.
Awesome, thanks for the feedback and glad we can help. You need a BRK (basic repair kit) which includes seal unit, upper and lower bearings and o-rings. Flygt Part no. 657 17 00 for Flygt Pump Model 3153.181
@@ivoyvo2024 if you send me your email address then I will send you an IOM with explosion view drawing and parts list for your pump
@@hahnuniversity6881 Thank you very much. I have the manual. Keep posting new videos. They are greatly appreciated.
You should consider getting a tear down tank. Makes tear down and quote a lot easier
Please elaborate or provide a link with video demonstration of this.
@@hahnuniversity6881 when I get into work Monday I will snap a pic of the one we use. The tear Dow tank we use is a work bench with grading covering it when you pull your oil plugs it drains all your glycol/oil in a tank
@@hahnuniversity6881 if you send me your email I will send pics not sure how to post pics in comments
@@jd4452 you bet, sounds good. jasonv@hahnequipment.com
Much thanks
Thank you so much I’m from Thailand Man tenants Assembly and service and repeat pump Flygt . Thank you for video ❤️ Perfect video 👍
What should be the resistance between thermal contacts T1 and T2. And if there is no resistance showing what does it mean ???
Simple field test - if you see "0L" on meter between thermal sensor wires (T1 and T2) then thermal sensor in motor is "open" and it is recommended to pull pump for further diagnosis. In terms of actual resistance in moisture relay in control panel if no warning lights are illuminated on relay then should be 1200 ohms resistance. If moisture relay is illuminated then fls moved, indicating water is in the leakage chamber, and there are approximately 300 ohms resistance.
@@hahnuniversity6881 Important to note that the pump has to stand upright when measuring, or you have to move the FLS float by hand. If you lay the pump down, the FLS can indicate water ingress even if there is none.
What would be the reading if there is water in the stator?
Awesome video
Great Vid💯💯
I disassemble the Flygt 3102 pump on its own in a maximum of 10-15 minutes.
Which grade oil using in this pump??
usa refrigerante esa serie de bomba flygt. La vieja versión llevaba aceite 15w40
Very good
Spandle oil
Michenical seel seal air chekad air pressoor
Very nice pump assmbl how many stator housing remov
How do you drop the stators?? I have 3 i can't get to drop it off the caseing...
You use two burners on each side of the statorhouse. Extreme heat so the stator does not gets more stuck. You prepare the new stator and turn the statorhouse upp side down and use the heat. Drop the new stator in the house and it will get stuck once it cooled of.
@@pumpnisse4633 ahh use 2, we only have 1 torch to use when dropping stators, the 3102 pumps are the biggest issues
how to repair stator
Si el estator esta dañado hay que rebobinar
how to remove the stator winding of flygt pump for rewinding?
video to dismantle the motor winding for rewinding purpose