Installation and repair all kinds òf cooling system
Відео
Strada aircon check up electrical problem
Переглядів 62 години тому
Strada aircon check up electrical problem
Crosswind aircon repair rear side evaporator may leak
Переглядів 24День тому
Crosswind aircon repair rear side evaporator may leak
Aircon wall type leak repair and re-proces
Переглядів 41Місяць тому
Aircon wall type leak repair and re-proces
Aircon 3 tuner leak repair and re-proces
Переглядів 20Місяць тому
Aircon 3 tuner leak repair and re-proces
Floor Mounted type Aircon cleaning and leak repair
Переглядів 41Місяць тому
Floor Mounted type Aircon cleaning and leak repair
Samsung inverter check up compressor it's not working
Переглядів 20Місяць тому
Samsung inverter check up compressor it's not working
Toyota vios aircon repair palit ng oring
Переглядів 32Місяць тому
Toyota vios aircon repair palit ng oring
Mitsubishi mirage hatchback Aircon repair rubber hose ng low side palit
Переглядів 492 місяці тому
Mitsubishi mirage hatchback Aircon repair rubber hose ng low side palit
Isuzu MUX repair palit ng hose ng high side
Переглядів 92 місяці тому
Isuzu MUX repair palit ng hose ng high side
Samsung inverter leak repair and re-proces
Переглядів 192 місяці тому
Samsung inverter leak repair and re-proces
Aircon window type repair digital switch convert to manual
Переглядів 212 місяці тому
Aircon window type repair digital switch convert to manual
Mazda Aircon leak repair and re-proces
Переглядів 132 місяці тому
Mazda Aircon leak repair and re-proces
😅😅😅
Naka design n nga Yan eh.
Bkit pinuputol un sa indoor
Wla ka ba flairing tools? Hahah Bkit pnutol mo ang fittings ng indoor😂😂😂😂😂😂 Copper pipe mo wla din sa standard haha Nagawa mo pa ivideo gnyan na trabaho?
boy hinang haha ..
Wala naman pong problima kahit lumakas ung hangin Hindi pa din magbabago ung lamig ng aircon kaya nga nakadesign ung outdoor fan blade nya Hindi pweding sumalungat ang ikot ng blade kahit malakas ang hangin
Bkit Jan Po s bubong.paano kung humangin Ng malakas hindi gaganda lamig s loob mapipigilan Ng hangin un outdoor.at mahirap pag maintenance
Good job mgkano mother board Ng Daikin idol
Hindi ata sila company shop ata sila
Bkit hinihinang p yun tubo sa may condenser.wla s quality
sub standard trabaho mu kawawa customer mu tinipid mu msyado ikaw dn mawawalang customer
90%mali 10% Tama😂😅😅 awit Kay kostumer 😅
kawawa pins :D .. ninipis pins :D .. at boy puto ng flaire nut ng indoor unit boy hinang 😂😂😂😂😂
putulin muna mahilig ka nman magputol ng fittings tpos welding mu :D
Bakit ninyo hininang eh bago yan, tst tst hindi tama yan mga sir
Yung iba kasing installer kinukuha yung mga original fittings ng indoor tapos hinihinang nalang ang connection. Paano nga kung kailangan ibaba ang indoor for servicing or cleaning, malaking problema para sa magservice. Kaya kung magpapakabit kayo ng split type tumawag din kayo ng medyo may alam para mabantayan ang installer.
Very good kna d2 sir pinaggiwalay Muna Ang dalawang copper tube sa dalawang isolation mabuti Yan sir nkikinig sa mga comment sa mas mapaganda mo Ang service mo at dumami Ang magtiwala syo.
Naku sir pasensya na need nyong bumalik sa school Hindi pwedeng ipagsama Ang dalawang copper tube sa Isang isolation magkaiba ng temp. Po Yan pwedeng maging dahilan pra magstop stop Ang andar ng Aircon tsaka madaling masira.
Hindi pa ata pinag separate ang insulation ng piping 🤦♂️
Boy hinang
Wala na sa standard tinipid nyo master
boy putol sa fittings ng indoor
Hay Naku very wrong 😢
Boy hinang
Boy hinang bobo
Bobo installer
Tinpid kawawa may ari ng aircon magkaka problema yan
10 feet standard copper tube po at vina vacuum po yan para matanggal ang moisture na nasa loob ng copper tube
Brad d ka man lang nag vacuum at nag leak test.Tsaka improper ang mga proseso mo.Paano manonood sa mga vlog mo ang mga gustong matuto sa refrigeration/ airconditioning.
Good Job.......👍👍👍👍👍
Dapat di pinagsama yung suction at discharge copper tube sa isang insulator dapat individual dahil magka iba ang temperture ng dalawang tubo in the long run magkakaproblema yan
Pwedi pla Yun...?Buti tatagal Ang Aircon na Yan...ganun ganun nlang pag kabit...kahit tambay pla pweding magkabit kung ganun lang Wala lahat Ng tamang procedure tatagal kaya Yan?
Siakol
Mga wala sa standard. Ndi ata sila well trained haynaku.
Warranty void, not properly installed, dapat hindi hininang at higit sa lahat dapat vinacuum
Sana pinag isipan nyo. Muna bago ninyo inilabas ang iyong aircon installation kung tama ba o nasa standard ba ang gawain namin,goodluck bro.
Parang Hindi na Kyo nag leak test at nag vaccium or nag furging.magkakaroon Ng moisture ung system nyo.
Hilaw ang lamig niyan, mediyo magastos sa kuryente kasi mediyo matagal niya maabot ung set temperature compared sa vinacuum sana para matangal ang hangin at moisture.
Mali nga yan dapat hiwalay dapat isang tube isang copper tinipid nila yan
Ndi standard ang installation nila. Hahaha kanya kanyang trip lang sila. Ka bago bago hinang na agad haha pati ung ung electrical walang flexible.. 😢😢
Ser, tanong ko lng bkit magksama yung 2 copper tubing sa 1 foam insulation? Hindi kya magka problema yung system pag tagal?
sap lagi ang instol nyo mga boss ausin nyon nmn un wire alang conduit d pa kau nag vaccum 😢😢😢😢
nag hinang pra maiwasan ang leak sa fitting ganyan din ginagawa ng kasama ko, ang nakita ko lng na mali hindi ina apply ang 10ft standard tubing, at loop, tinipid sa materials, sa vacum naman dipindi sayo kasi bago ang unit, Purging or vacum no problem
The installation was not neat, why wasn't the pipe circle installed behind the AC?
Walang vacuum vacuum walang leak test derecho release lahat Ng freon 😂
Seminar po kayo sir pr s proper installation ng split type...tsaka kayo mag vlog ng tama😔
location nyo boss
Mgkno bayad pag gnyang repair boss
Sablay ka paano kapag nagpumpdown eh di magccut kpa uli ng tubo.minsan isip isip din.lalot ksilangan ibba ang indoor.
Pati wiring dimaayos,at di magvaccum,at naghinang pa,hahahahahaha magaling????
Kaya nga master pinutol ang nut ng indoor unit...