How Valve Positioner Works | Hook's Law
(🔴) Link to E-Book on Control Valve Mastery
👉 www.asad-shaikh.com/control-valve-mastery.html
What is a Control Valve Positioner?
In industrial processes, control valves play a crucial role in regulating fluid flow, pressure, and temperature. However, to achieve precise control, a control valve positioner is often necessary. A positioner is a device that accurately controls the movement of a control valve, ensuring it reaches the desired position in response to a control signal.
Working Principle of Control Valve Positioners
The working principle of a control valve positioner is based on a feedback control loop. The positioner receives a control signal from a controller or PLC, which compares the desired valve position with the actual position. If there's a deviation, the positioner adjusts the valve's movement to match the desired position. This process occurs continuously, ensuring the valve remains at the correct position.
Types of Control Valve Positioners
There are two primary types of control valve positioners:
1. Pneumatic Positioners: Use compressed air to move the valve stem.
2. Electric Positioners: Use an electric motor to move the valve stem.
How Positioners Improve Valve Performance
Control valve positioners enhance valve performance in several ways:
1. Accurate Control: Positioners ensure the valve reaches the desired position, reducing errors and improving process control.
2. Increased Precision: Positioners can achieve precision of ±1% or better, depending on the application.
3. Faster Response Times: Positioners respond quickly to changes in the control signal, reducing process upsets.
Benefits of Using Control Valve Positioners
The benefits of using control valve positioners include:
1. Improved Process Control: Accurate control of valve movement ensures consistent process conditions.
2. Increased Efficiency: Reduced errors and faster response times lead to improved process efficiency.
3. Extended Valve Life: Positioners reduce wear and tear on valves, extending their lifespan
Переглядів: 1 352

Відео

Instrument Index Preparation | For Mega-Scale Projects
Переглядів 1,1 тис.Місяць тому
Tag Number The tag number is a unique identifier assigned to each instrument in the plant. This field is essential for identifying the instrument in the index and other documentation. The tag number is often used as a reference in other records, such as maintenance schedules, calibration records, and repair histories. Loop Number The loop number refers to the specific loop or circuit that the i...
How Cryogenic Valves Work at -196°C | Extreme Engineering
Переглядів 1,1 тис.Місяць тому
The Working of Control Valve in Cryogenic service is based on the principle of physics that when the temperature rises the cryogenic liquid turns to gas and this creates a insulation that prevents the cold temperature to reach the actuator or electronics. 🔴Can you learn from ENGINEER's around the WORLD ? Yes ? For FREE (Without any strings attached) Here is a "Group" where every month we take "...
Control Valve Trim Selection | What Experts Know
Переглядів 1,2 тис.Місяць тому
Cage Guided Valves : These cage-guided globe valves throttle flow by uncovering more or less of the port area in the surrounding cage as the plug moves up and down Stem Guided Valves : Globe valves restrict the flow of fluid by altering the distance between a movable plug and a stationary seat (in some cases, a pair of plugs and matching seats). Fluid flows through a hole in the center of the s...
Control Valve Sizing - What is Piping Geometric Factor
Переглядів 1,6 тис.2 місяці тому
Control Valve sizing requires a lot of engineering judgement. In control Valve Sizing we need to be cautious to size the valve in such a wat that it is not oversized. However, in this video you will learn about the Piping Geometric factor in control valve sizing and that without considering it you might be under sizing the control valve which can have heavy consequences. You will learn what is ...
Why CV Datasheet has 6 Leakage Class & it does NOT matter much
Переглядів 1,9 тис.2 місяці тому
The term “Control Valve Seat Leakage Class” comes from ANSI / FCI 70-2. This is a control valve seat leakage specification Standard. 🔴 Link to Join Advanced Instrumentation WhatsApp Community 🔴 👉 chat.whatsapp.com/G1Aon6ZnbEJFRzDpZEv7ir Valve Leakage Classifications Class I - Valve Leakage Classifications Identical to Class II, III, and IV in construction and design intent, but no actual shopte...
"4 to 20 Method" for DP Interface Level Calculation
Переглядів 1,3 тис.3 місяці тому
🔴Can you learn from ENGINEER's around the WORLD ? Yes ? For FREE (Without any strings attached) Here is a "Group" where every month we take "Questions" from Engineer around the world and share the Answers with the ENTIRE community So EVERYONE learns and Benefits Introducing !! 👉 "Advanced Instrumentation" WhatsApp Community Where you will learn from 1) Monthly Q&A session on Advanced Instrument...
7 Bonnet Selection Criteria in Control Valves- Explained
Переглядів 1,8 тис.3 місяці тому
Links 👉 WhatsApp Private Group (Advanced Instrumentation) Link to join : chat.whatsapp.com/G1Aon6ZnbEJFRzDpZEv7ir Extension Bonnet: Extension bonnets are utilized in applications where the operating temperature is extremely high or low, necessitating insulation of the valve stem from the process fluid. These bonnets feature an extended length, allowing the stem to protrude beyond the insulation...
Control Valve Actuator Power Selection under 2 mins ⏱️
Переглядів 1,1 тис.3 місяці тому
🔴 Link to FREE E-Book on CONTROL VALVES 🔴 👉www.asad-shaikh.com/control-valve-mastery.html Pneumatic Actuators: Pneumatic actuators utilize compressed air to generate mechanical motion, making them popular choices for applications requiring fast response times and simple operation. These actuators typically consist of a piston enclosed within a cylinder, with air pressure acting on one side to d...
Control Valve Selection (Most LOGICAL Explanation)
Переглядів 4,7 тис.4 місяці тому
#controlvalve #controlvalves Selection Learn about control valve working, control valve selection like when to used Globe Valve, butterfly Valves, Plug Valves, Diaphragm Valves, Y Pattern Globe valve, Angle Valves and much more. Link to FREE E-Book on Control Valves 👇 www.asad-shaikh.com/control-valve-mastery.html
How to Calculate ASME Flange Ratings Explained
Переглядів 3,3 тис.4 місяці тому
ASME standards, including ASME B16.5, B16.47, B16.36, and B16.34, provide guidelines for the design, manufacturing, and testing of pipe flanges and flanged fittings. These standards play a crucial role in ensuring the safety and reliability of piping systems in various industries. One aspect that often confuses engineers and professionals is the presence of various flange ratings within these s...
5 Flange Facing types must-know for every engineer
Переглядів 3,1 тис.4 місяці тому
🔴 FREE E-book on Control Valves 👉Link to Download : www.asad-shaikh.com/control-valve-mastery.html Flat Face (FF): The Flat Face flange facing is characterized by a smooth, flat surface perpendicular to the pipe axis. It is suitable for low-pressure applications where sealing is achieved with a gasket between the flange faces. Flat face flanges are easy to align and provide a large contact area...
8 Must-Know API Valve Standards for Engineers
Переглядів 5 тис.4 місяці тому
The American Petroleum Institute (API) has established several standards that govern the design, manufacturing, and testing of valves used in various industries, including oil and gas, petrochemical, and power generation. Among these, several key standards stand out for their impact and widespread adoption. API 600 - Steel Gate Valves - Flanged and Butt-welding Ends, Bolted and Pressure Seal Bo...
Control Valve Noise Reduction Techniques
Переглядів 2,4 тис.5 місяців тому
🔴 FREE E-book on Control Valves 👉Link to Download : www.asad-shaikh.com/control-valve-mastery.html IEC Standards for Control Valve Noise: The International Electrotechnical Commission (IEC) establishes standards to regulate control valve noise. Notably, IEC 60534-8-3 provides guidelines for predicting and measuring control valve noise levels. Compliance with such standards ensures that control ...
Thermocouple Selection Criteria with Examples
Переглядів 1,1 тис.5 місяців тому
🔴 FREE E-book on Control Valves 👉Link to Download : www.asad-shaikh.com/control-valve-mastery.html Here's a brief guide for the selection process among some commonly used thermocouple types: Type K, Type N, Type J, and Type E. 1. Type K (Chromel/Alumel): Temperature Range: -200°C to 1,372°C (-328°F to 2,502°F) Applications: Versatility defines the Type K thermocouple, making it a go-to choice a...
Fugitive Emission Valve Standards | ISO 15848 | TA Luft | API 641
Переглядів 2,6 тис.6 місяців тому
Fugitive Emission Valve Standards | ISO 15848 | TA Luft | API 641
Control Valve Sizing Made Simple | 3 Golden Rules
Переглядів 11 тис.6 місяців тому
Control Valve Sizing Made Simple | 3 Golden Rules
Cracking the Interview : On-Off Valve | Top 3 Interview Q&A in 2024
Переглядів 2,2 тис.6 місяців тому
Cracking the Interview : On-Off Valve | Top 3 Interview Q&A in 2024
Valve Material Selection | SS316 | ASTM A105 | SS304 | Duplex 2205
Переглядів 4,2 тис.7 місяців тому
Valve Material Selection | SS316 | ASTM A105 | SS304 | Duplex 2205
Control Valve Working | Positioner | Actuator Selection | Trim
Переглядів 2,7 тис.7 місяців тому
Control Valve Working | Positioner | Actuator Selection | Trim
What is Safety Instrumented System | Voting 2oo3 | SIF | PFD Explained
Переглядів 6 тис.8 місяців тому
What is Safety Instrumented System | Voting 2oo3 | SIF | PFD Explained
FREE Course on Instrumentation and Control Revision | Finally Released on UDEMY 🎬
Переглядів 1,1 тис.8 місяців тому
FREE Course on Instrumentation and Control Revision | Finally Released on UDEMY 🎬
Thermocouple Extension cable vs Compensating cable | Best Selection | Industrial Experience
Переглядів 2,6 тис.8 місяців тому
Thermocouple Extension cable vs Compensating cable | Best Selection | Industrial Experience
Relief Valve Working | Types | Rupture Disk Combination
Переглядів 4,5 тис.9 місяців тому
Relief Valve Working | Types | Rupture Disk Combination
What is Split Range Control ? | World's Craziest Explanation Ever
Переглядів 11 тис.9 місяців тому
What is Split Range Control ? | World's Craziest Explanation Ever
How ON-OFF Valve Works via control System | The Hidden secret of 3 Way Valve
Переглядів 4,6 тис.9 місяців тому
How ON-OFF Valve Works via control System | The Hidden secret of 3 Way Valve
NO vs. NC Valves : How the combination works
Переглядів 2,2 тис.10 місяців тому
NO vs. NC Valves : How the combination works
Mastering Orifice Interview Questions: Top 3 MOST ASKED in 2023
Переглядів 4,9 тис.10 місяців тому
Mastering Orifice Interview Questions: Top 3 MOST ASKED in 2023
Mastering Relief Valve Interview Questions: Top 3 MOST ASKED in 2023
Переглядів 2,5 тис.10 місяців тому
Mastering Relief Valve Interview Questions: Top 3 MOST ASKED in 2023
How to DE-CODE line Number in P&ID | Piping & Instrumentation Diagram
Переглядів 3,9 тис.11 місяців тому
How to DE-CODE line Number in P&ID | Piping & Instrumentation Diagram

КОМЕНТАРІ

  • @anirudhaghadel3688
    @anirudhaghadel3688 2 години тому

    Lots of information as usual ❤❤

  • @rajurastogi8991
    @rajurastogi8991 16 годин тому

    Very well explained

  • @shahzadmallick6961
    @shahzadmallick6961 19 годин тому

    Great

  • @NicholasMurphy-u1s
    @NicholasMurphy-u1s День тому

    Can you explain maximum blowing pressure?

  • @GunaSekaran-ok1ds
    @GunaSekaran-ok1ds День тому

    Please teach interface level measurement and density measurement. Thank you so much

  • @AsadPassionateEngineer
    @AsadPassionateEngineer 2 дні тому

    🔴3:03 Correction: Please read 👉Min Traffic as 👉Max Traffic and 👉Max Traffic as 👉Min Traffic in the Graph My sincere apology for the mistake !! and thank you for highlighting the mistake 😊

  • @sagarmistry7019
    @sagarmistry7019 2 дні тому

    1st time watching such a great video.. keep it up.. really excellent

  • @pravinsinghrajput3566
    @pravinsinghrajput3566 4 дні тому

    Thank you 👍

  • @pravinsinghrajput3566
    @pravinsinghrajput3566 4 дні тому

    Informative

  • @pravinsinghrajput3566
    @pravinsinghrajput3566 4 дні тому

    Thank you 😊

  • @ckgadgets2513
    @ckgadgets2513 4 дні тому

    I Am Happy to watch Your Videos and to say that i just seen that your the alumni of VESIT I Also Currently Pursuing In final Year In VESIT And It's Proud To Seen Some Of Our College Senior Is doing Well For student. Keep Doing Best Of luck..!!

  • @Axifmalik
    @Axifmalik 6 днів тому

    Hi sir its great video.. can you please make a video on Material Requisition.. review and prepation.. Vendor Document Review .. Techinal Bid Evaluation.. Much needed video 😊😊

  • @kmaarouf1
    @kmaarouf1 6 днів тому

    If you use 4-20mA as a control signal, then two gauges are enough. The third gauge would have been used on older 3-15 psi control signal positioners (but can still be is used with 4-20mA control signal when you have double acting actuators)

  • @samikatnet
    @samikatnet 7 днів тому

    No exact details provided about Radius and Pipe tappings. Tapping location and for which size of pipe to be used not mentioned

  • @Axifmalik
    @Axifmalik 8 днів тому

    ❤❤❤❤🎉🎉🎉🎉

  • @brianmezieres61
    @brianmezieres61 8 днів тому

    Thank you for sharing very informative

  • @ilayapriya
    @ilayapriya 11 днів тому

    Orifice,DCS,soft signal,wireless signal type

  • @sajedussalammallickmallick8638
    @sajedussalammallickmallick8638 14 днів тому

    VERY GOOD

  • @ritesheie
    @ritesheie 14 днів тому

    Unit of torque is Newton Meter,why in the diagram it is n/m3?

    • @AsadPassionateEngineer
      @AsadPassionateEngineer 12 днів тому

      You are correct. Please refer Pinned Comment - It was a mistake from my side . Apology for the error 😊

  • @NithinNayak-dm2ii
    @NithinNayak-dm2ii 15 днів тому

    What does the third gauge indicate?

    • @kmaarouf1
      @kmaarouf1 6 днів тому

      See my comment - If you use 4-20mA as a control signal, then two gauges are enough. The third gauge would have been used on older 3-15 psi control signal positioners (but can still be is used with 4-20mA control signal when you have double acting actuators)

  • @fatehrizwan816
    @fatehrizwan816 18 днів тому

    Assalamualaikum Mr Asad kindly give me your contact number i need to discuss about instrumentation design eng course

  • @wsiddig1
    @wsiddig1 18 днів тому

    Thanks Asad.

  • @craighudy4196
    @craighudy4196 18 днів тому

    The honey vs water comparison notes the cause as honey being very dense when the issue is actually honey have very high viscosity. Unfollow this channel unless you want to make stupid mistakes like this guy.

  • @wasimakram3315
    @wasimakram3315 19 днів тому

    Hi Asad .. thanks for this amazing video.

  • @shrishmishra2807
    @shrishmishra2807 19 днів тому

    Hi asad ...big fan of your content and your dedication....I want one solution to have a predictive method to get positioner malfunction....as everytime we check some positioner when we get some problem I am looking for some dashboard think to get every positioner health on single DCs screen

  • @lithiusx
    @lithiusx 22 дні тому

    Is this wire compatible with any digital input? An open circuit during normal times, and a short circuit after a heat event?

  • @adilfarooq9009
    @adilfarooq9009 22 дні тому

    I think you explained your analogy with the car backwards/improperly when repeated later in the video. How is it that the Cv (or speed) would be high in maximal traffic conditions? You showed it this way at least a couple of times. You should fix it.

    • @AsadPassionateEngineer
      @AsadPassionateEngineer 2 дні тому

      3:03 Correction: Please read Min Traffic as Max Traffic and Max Traffic as Min Traffic in the Graph (My Apology for the mistake)

  • @narendhraraju
    @narendhraraju 23 дні тому

    Very interesting asad thank you

  • @ganeshmanjalkar3004
    @ganeshmanjalkar3004 26 днів тому

    How to get job in design field at initial stage ? It is very hard to find a job because many of companies required 2-3 years of experience in design. Where and how to start ?

  • @Nursulton-lf4ik
    @Nursulton-lf4ik 27 днів тому

    Kygdiyd

  • @bharathidasan7144
    @bharathidasan7144 27 днів тому

    Yes we are waiting for part 2 video,please upload asap .

  • @anishktym
    @anishktym 28 днів тому

    how to review a wake frequency calculation from vendor. what are the main points to be check

  • @anishktym
    @anishktym 28 днів тому

    hi

  • @anishktym
    @anishktym 28 днів тому

    how to review a wake frequency calculation from vendor. What are the points to be checked?

  • @sanketpatel1451
    @sanketpatel1451 Місяць тому

    Sir, If beta ratio of orifice is 0.8 then we should reject it or anything else we need to check. Please confirm sir... Thank you.. If possible please make a video what to do if beta ratio is high then 0.8 or less than 0.3. Thank you in advance sir

  • @sastatravellerxasifhood4858
    @sastatravellerxasifhood4858 Місяць тому

    Nice video..Instrument index also cover Instrument type,then subtype ,line no,line size ,pipe class ,Tracing either heat tracing or steam tracing if there is valve then Valve size and its position i;e Fail open ,fail close TSO AFC etc Then Location of instrument ,then Signal Direction From DCS to Field ,then what type of system either DCS or ESD or FGS etc..and many more..

  • @AnandSingh-qv5qv
    @AnandSingh-qv5qv Місяць тому

    Could you plz update in detail, like main thing motor related details, like XL, XA, soft tag hardwire tag, details in DI/DO signal, In addition to that, which signal is Control indicating and recording, Indicating, indicating and recording, alarming, controlling, like we use to populate in SPI. You are requested to cover above topic. Thanx

  • @videonsr
    @videonsr Місяць тому

    Can you provide cause and effect Matix

  • @falaksher5512
    @falaksher5512 Місяць тому

    make a video on Cause and effect diagram... which signals should be on top and down... is there any phelosphy for C&E

  • @tinnieds16
    @tinnieds16 Місяць тому

    please add part 2 and also include index for motors

  • @Bookshotsofficial1
    @Bookshotsofficial1 Місяць тому

    Useless document seriously ?

  • @patel596
    @patel596 Місяць тому

    Thanx a lot for such a good knowledge sharing with us🙏

  • @patel596
    @patel596 Місяць тому

    Yes we brief about index

  • @avinashc5700
    @avinashc5700 Місяць тому

    Yes required

  • @danielodeliro2412
    @danielodeliro2412 Місяць тому

    Thanks

  • @ainaalharthy9747
    @ainaalharthy9747 Місяць тому

    Indians are the best explainers 🙏🏼🩷

  • @vivekryadavofficial
    @vivekryadavofficial Місяць тому

    Ohh God !! What an explanation!!❤ Thank You.

  • @sandeshwarghade8241
    @sandeshwarghade8241 Місяць тому

    Thank you sir 🤝

  • @kshitijtakarkhede7833
    @kshitijtakarkhede7833 Місяць тому

    Asad sir , we understand you are busy in your work , but its humble request can you please make video like "skillset or Things " one should know to join as fresher in I&C offcampus , and what "skillset are required" to get from fresher to senior I&C engineer, I do understand it will really depends on which industry working on but can you please make a video on this as there is no one guiding for that noone , please kindly look into this aspect too, enjoyed all your videos and waiting for Amazing videos , it will give a headstart for freshers what to follow and also resolve most of the doubts.

  • @Ashumi
    @Ashumi Місяць тому

    Thank you.