Muhammad Hammad
Muhammad Hammad
  • 3
  • 1 873
HAP 5.1 LOAD CALCULATION FOR HVAC SYSTEM BY HAMMAD
In this video, I have explained complete load calculation using HAP Software for HVAC Design.
discussed about ASHRAE 62.1 Standard. U-factor values of wall, roof, window.
for more updates follow me on linkedin
linkedin.com/in/muhammad-hammad-405585214
#hvac #mep #revit #engineering
Переглядів: 200

Відео

HAP 6.2. How to convert AutoCAD drawing to pdf on a proper scale for HAP 6.2HAP 6.2. How to convert AutoCAD drawing to pdf on a proper scale for HAP 6.2
HAP 6.2. How to convert AutoCAD drawing to pdf on a proper scale for HAP 6.2
Переглядів 123Місяць тому
If you are facing problem that pdf is not clearly visible in HAP 6.2 then this video is for you. in this video I have explained that how you can convert autocad drawing to pdf format on a proper scale. if you have any query, you can ask me on linkedin www.linkedin.com/in/muhammad-hammad-405585214
HAP 6.2 COMPLETE GUIDE BY HAMMADHAP 6.2 COMPLETE GUIDE BY HAMMAD
HAP 6.2 COMPLETE GUIDE BY HAMMAD
Переглядів 1,6 тис.2 місяці тому
A complete Guide to HAP ( Hourly Analysis Program ) 6.2. A Golden video for HVAC and MEP Engineers. Heat and Cooling load Calculation is discussed and system like VRF, Water Cooled chiller, air handling unit or split air conditioner unit system is composed to generate reports on load calculations. IF YOU HAVE ANY QUESTION THEN COMMENT OR CONTACT ME AT linkedin.com/in/muhammad-hammad-405585214

КОМЕНТАРІ

  • @NajamUdDin-o1k
    @NajamUdDin-o1k 14 годин тому

    Can you give me private classes sir?

  • @NajamUdDin-o1k
    @NajamUdDin-o1k 14 годин тому

    Very informative video sor teach me please

  • @akram2537
    @akram2537 2 дні тому

    Hello sir , i have a problem with roof thermal load in HAP 6.2 , if i draw a roof in the "level section" and choose roof perimeter above some spaces, there is no roof load in these spaces , any solution please ?

    • @MuhammadHammad0747
      @MuhammadHammad0747 День тому

      Remove ceiling and you will get roof thermal load. In hap 6.2, if you place ceiling then hap will show just ceiling thermal load and no roof load. Dont forget to follow me on LinkedIn www.linkedin.com/in/muhammad-hammad-405585214

  • @akram2537
    @akram2537 2 дні тому

    Hello sir, thanks for the video. I have a a problem, when i define roofs and their perimeter, there is no roof thermal load when i simulate the air system !! is there a solution ?

    • @MuhammadHammad0747
      @MuhammadHammad0747 День тому

      Remove ceiling and you will get roof thermal load. In hap 6.2, if you place ceiling then hap will show just ceiling thermal load and no roof load. Dont forget to follow me on LinkedIn www.linkedin.com/in/muhammad-hammad-405585214

  • @Actively-b8s
    @Actively-b8s 18 днів тому

    HI sir good work and much appreciated your effort sir i m facing a problem and want your or some one form the comments box can solve my issue im working on residence building project as i have done every thing just when i go in space type i want to select speac type for bedroom which im ot find any one or sir can you answer me immediately because this i have to submit to consultant but i can't complete just because of this issue

    • @MuhammadHammad0747
      @MuhammadHammad0747 18 днів тому

      @user-jh2hk5mh2z in the hotel section, select break room. Basically for residential buildings ashrae standard 62.2 is used. You can make a user defined space type for it froam ashare 62.2 or just select break room of hotel/motel as told you earlier

  • @tarekali5287
    @tarekali5287 24 дні тому

    How can we add fresh air for some spaces. For example i need to add 100 cfm fresh air not treared to one space.

    • @MuhammadHammad0747
      @MuhammadHammad0747 24 дні тому

      @tarekali5287 if you want to enter untreated air, then why to add it in calculation. And if you want to add treated fresh air. Then you can set user defined in ventilation column and enter the required cfm or you can enter that cfm in exhaust column . It will be indirectly consider exhaust rate=same amount of fresh air intake

  • @engr.muhammadshahid
    @engr.muhammadshahid Місяць тому

    Thank you sir, bit I want to know if you have the paid version of the HAP or cracked. If cracked please share the setup with us.

  • @sheblalameri7891
    @sheblalameri7891 Місяць тому

    Thank you so much

  • @sheblalameri1342
    @sheblalameri1342 Місяць тому

    ((Space Model hospotal 340 Zone "bath" contains no spaces.)) ihave these problem when ichoose un conditions space in zoning in space model proprties

    • @MuhammadHammad0747
      @MuhammadHammad0747 Місяць тому

      @@sheblalameri1342 www.linkedin.com/in/muhammad-hammad-405585214 . Follow me on LinkedIn

    • @MuhammadHammad0747
      @MuhammadHammad0747 Місяць тому

      @sheblalameri1342 when you create automatic zones and then uncondition that zone space. The zone remains there but the spaces moves to unconditioned space. Delete that zone in zoning tab and your issue will be resolved. For a a video follow me on LinkedIn

    • @sheblalameri7891
      @sheblalameri7891 Місяць тому

      @@MuhammadHammad0747 its working thank you soo much

    • @MuhammadHammad0747
      @MuhammadHammad0747 Місяць тому

      @@sheblalameri7891 happy to know that 😃

  • @sheblalameri7891
    @sheblalameri7891 Місяць тому

    Ihave problem when i open pdf in hap the pdf is not clear

    • @MuhammadHammad0747
      @MuhammadHammad0747 Місяць тому

      @@sheblalameri7891 try to scale your drawing on a large page like A1 size or A0 Size on autocad. It will solve your problem

    • @MuhammadHammad0747
      @MuhammadHammad0747 Місяць тому

      @@sheblalameri7891 if you want a video on how to convert pdf from autocad on a proper scale. Then please let me know

    • @sheblalameri7891
      @sheblalameri7891 Місяць тому

      @@MuhammadHammad0747 please, make vedio , and how to make the scale in dwg the same in hap exactly , and how to export all floors in one pdf from autocad, thank you so much

    • @sheblalameri7891
      @sheblalameri7891 Місяць тому

      @@MuhammadHammad0747ihave one more problem when I chose unconditiona spce in zoing then igo to previews the ruselt igot error 340 in result (contians no space ) in error description

    • @MuhammadHammad0747
      @MuhammadHammad0747 Місяць тому

      @@sheblalameri7891 ok sure.

  • @rizwanansari-wd2uq
    @rizwanansari-wd2uq Місяць тому

    How to install

  • @AmirTeachesMath9-12
    @AmirTeachesMath9-12 Місяць тому

    Keep good work.

  • @farhansheikh6589
    @farhansheikh6589 2 місяці тому

    What if i have to assign my space is above condition space or in between condition space, how can i do this if you know please tell me

    • @muhammadhammad2266
      @muhammadhammad2266 2 місяці тому

      While making zones, unconditioned spaces are marked. From this , hap understand that which space is conditioned and which is not. And take partion wall and partition celling according

    • @muhammadhammad2266
      @muhammadhammad2266 2 місяці тому

      And for first floor, it gives options of at grade, or have basements ...like that.... but for spaces. You just have to mention it on zoning and hap will mark partions accordingly

    • @MuhammadHammad0747
      @MuhammadHammad0747 2 місяці тому

      In the space model, while creating zones. Just mention unconditioned spaces. Hap will autopick wall and ceiling partition accordingly. In zoning tab, we make zones and also select unconditioned spaces

    • @farhansheikh6589
      @farhansheikh6589 2 місяці тому

      Sorry you didn't get my question, My question is if I am doing any office space load calculation and the space is on 7th floor and all the below and above floor is condition, how can I assign this condition.

    • @MuhammadHammad0747
      @MuhammadHammad0747 2 місяці тому

      Upto my understanding, we have to create 3 levels. Place the same floor plan on each level. Create walls and spaces for that floor plan and copy paste it on other floors. At zone tab, make zones for the levels. Then create individual system for each level. At alternatives when you generate reports. Just select the middle floor. Which is basically your 7th floor and you will get load calculation of 7th floor which is in middle of two conditioned floor

  • @abramehab7893
    @abramehab7893 2 місяці тому

    Good job

  • @farooqakash6874
    @farooqakash6874 2 місяці тому

    Sir you have HAP crack version?