Hi Guys! My name is Aadil and i would like to welcome you to my channel! on this channel I bring tech reviews,siemens product, Auma valve, Auma Picv,PLC&SCADA,Profibus PA & Callibration process with tools etc. make may day by subscribing to the channel!
How to start district cooling plant
#tranechiller #districtcoolingplant #royalcommissionjubail #jicplant #saudiarabia
Переглядів: 796
Відео
How to Operate the Panametrics PT878 Ultrasonic Liquid Flow Meter #PT878
Переглядів 4,3 тис.3 роки тому
How to install clamp on fixtures and transducers onto a pipe. Overview and demonstration of how to install clamp-on fixtures and transducers onto a pipe for use with a PT878 flow meter. After the PT878 flow meter has been programmed, the meter will give you a transducer spacing based on the number of traverses selected. The spacing is the distance between the transducers to be installed. Be sur...
13.8 KV Vacuum Circuit breaker Contact Resistance Test
Переглядів 3,1 тис.3 роки тому
In this video i have shown how to do contact resistance test for 13.8kv vacuum circuit breaker by using fluke 1555 insulation tester.
Trane Centrifugal chiller 3000 Ton Startup & shutdown.
Переглядів 8 тис.3 роки тому
In this video i will show you how to start Trane Centrifugal chiller 3000 Ton,before you start the chiller you must know the Some important parameter as follow below. Chiller setpoint: 4.4 degree celcius Diffrential Start: 1/1.5 degree celcius Diffrential Stop: 0.6 degree celcius Evaporator Side Flow: 568 L/s Condensor Flow: 473 L/s Entering Temp:13.33 degree celcius(Maximum) Condensor Enterig ...
How to configure Profibus PA field device a using of SIMATIC PDM Software #SITRANSTH400TRANSMITTER
Переглядів 5 тис.4 роки тому
in this video i will show you how to do configuration of Profibus PA device and how to change the profibus addres, how to change input and output parameters. #SITRANSTH400#TEMPERATURETRANSMITTER#RTD#CALIBRATION#PDMSOFTWAREV9.1
Profibus Field Device Coupler & PC ADAPTER USB A2 #SITRANSTH400#TEMPERATURETRANSMITTER#CALIBRATION
Переглядів 1,1 тис.4 роки тому
How to setup field device coupler & Pc Adapter PC A2 for configuration of SITRANS TH400. Part no#6GK157-0BA00-0AA0(PC Adapter USB A2) Part no#6ES7658-3GX68-0YT8(SIMATIC PDM SOFTWARE) Part no#6ES7658-3AB68-0YA5(LICENSE KEY) Part no#157-0AC85-0XA0(FIELD BUS COUPLER) Brand#Siemens
How to Install Siemens SIMATIC PDM Software #simaticpdmsoftware#pdmv9.1
Переглядів 2,8 тис.4 роки тому
In this video I will show you how to install Siemens SIMATIC PDM software step by step. Part no#6GK157-0BA00-0AA0(PC Adapter USB A2) Part no#6ES7658-3GX68-0YT8(SIMATIC PDM SOFTWARE) Part no#6ES7658-3AB68-0YA5(LICENSE KEY) Part no#157-0AC85-0XA0(FIELD BUS COUPLER) Brand#Siemens
Energy Transfer Station #energytransferstation #heatexchanger #districtcoolingplant
Переглядів 1,4 тис.4 роки тому
How Energy Transfer Station works in district cooling plant.
SITRANS F M Verificator used for testing the Magnetic Flow meters #sitransfmverificator
Переглядів 2,5 тис.4 роки тому
In this video we explain the program in more details and show you exactly what the SITRANS F M Verificator can do. The SITRANS F M Verificator checks the general operations of the Flow Meter but also that the Flow meter is within specification including the Sensors Magnetic properties. the process takes only 15 Minutes and is fully automated, after tests we can print Verification Certificate fo...
Networking connection of Server/Scada Panel | how to ping #serverpanel#scadapanel#networking#ping
Переглядів 7424 роки тому
In this video I discuss what is Ethernet Switch, what it does,how to change Internet Protocol(IP address),how to Ping networking of Server/Scada Panel as well as how to do cable connection from Switch to Host. #Networkingconnection#ping#scadapanel#serverpanel
Introduction to District Cooling Plant & Energy Transfer Station #coolingplant#dcp#chillerplant#ets
Переглядів 8 тис.4 роки тому
In this video I discussed steps by steps what is DCP & ETS, what it does, what are the major Process equipment & what is the important Parameter for Operating to DCP & ETS #districtcoolingplant#coolingplant#dcp#ets#energytransferstation#chillerplant
#BTUMETER | How to calculate Energy Consumption/Ton(Demand) | How BTU meter working and connection.
Переглядів 4,4 тис.4 роки тому
#BTUMETER | How to calculate Energy Consumption/Ton(Demand) | How BTU meter working and connection.
How To Connect Rj45 Connector In Cat6/Ethernet Cable#Cat6cable#Ethernetcable
Переглядів 6464 роки тому
How To Connect Rj45 Connector In Cat6/Ethernet Cable#Cat6cable#Ethernetcable
How to Setup Fluke 7103 Micro Bath & How to Calibrate Temperature Gauge#Temperaturegaugecalibration
Переглядів 4,8 тис.4 роки тому
How to Setup Fluke 7103 Micro Bath & How to Calibrate Temperature Gauge#Temperaturegaugecalibration
#SITRANS FM MAG 5000/6000#SIEMENS ELECTROMAGNETIC FLOW METER/TRANSMITTER #InstrumentandControlguru
Переглядів 11 тис.4 роки тому
#SITRANS FM MAG 5000/6000#SIEMENS ELECTROMAGNETIC FLOW METER/TRANSMITTER #InstrumentandControlguru
#PICV(Pressure independent control)#Modulating valve Auma Actuator Settings#instrumentandcontrolguru
Переглядів 3,1 тис.4 роки тому
#PICV(Pressure independent control)#Modulating valve Auma Actuator Settings#instrumentandcontrolguru
Brother ETS room ka size kitna huga and height. Or u can say space required for one Heat exchanger and height
Thnx brother 👍👍 so butyfull video 😊
Thanks 😊
Mast Guru.
Good job 🎉❤
Hi anyone please advise, the district cooling estimated load for 1 building( ie: an apartment building required 1000TR (3500kW)= DC Plant load of 3500/5(cop)=700kW). This 700kW is the total energy consumption including the ETS and DCP load ? Or do we need to add a separate power consumption for the both ETS and DC plant’s mechanical load??? If someone have the actual energy consumption rule of thumb, please comment…
Hello sir, where i can connect my pc to configure the sensor with profibus pa
Do you have pdm software?
Buenas, cual es la clave para ingresar y resetear el totalizador de un flujometro SITRANS FCT030
Please make a video, where are all the safety devices on the train chiller? Practically, please make a video for us.
Sir can you upload a video in which update all parts of chiller tell us
I am trying to edit Calibration Factor, but it is not getting edited. Please guide me how can i edit Calibration Factor.
Did you install Sensorprom?
Need more information please sir , Thank you
Very good information sir ji , Thank you so much
Very good
Do you know where you can buy one of these used?
From Siemens suppliers.
Good 👍 brother
Thanks. After sensor replacement, do we need to configure it? Is there any way to bypass it? Our chiller is still not working, even after replacement... Can anyone tell please?
Need software for binding
Thank you brother
Sir, purge unit kyo hota hai bataye.
Trane CDHG water cooled chiller Refrigerant- R123 Problem- chiller not going load more than 80% and not achieve set temp,we changed leaving water sensor,saturation sensor,charged refrigerant,water flow normal,igv manually open working normal but still load going ,not achieve set point temp
Try to charge refrigerant
How to set.??? 30kl water tank full hone par band ho jaye.. isme kiya setting karna hoga
you can install level transmitter and do the programming to stop the filling tank at your setpoint
Sir I can not asign pa address when I install new address,it showing already used,how can I solve this?
remove the sensor from the field and connect only one sensor(Damage) then you change it.
Some one can share me a virtual machine with pdm program,or sell it
please give me a feed back regarding normal surge shutdown keep going on
Check condenser flow, Condenser water temperature .
sir WTI And OTI demonstration with isotech venus site available?
Dear sir , I need help regarding this flow meter installation and competent person's contact no from ge side in india,
Why we call it 13.8KV VCB contacts resistance test?
man, Why did you put on K factor 477.08842, if the transmitter is 477.088341?
you can check the factor from sensor box .
Thanks for making this video
Bhai Trane chiller RTAF me sensor kaise fix karenge
Direct DCP se 4.4 degree Celsius phir use hm heat exchanger se pass kara k 5.5 q kar rha h 4.4 is better please clear my doubt
Dcp se 4.4 degre Celsius supply jata ha ETS mai Jane ke bad 1 degree Celsius approx increase ho jata ha because distance from dcp.
Plate Heat exchange se pahle 5.5 degree Celsius approx ab depends krta ha client ka demand kya ha temperature usi ke according setpoint set karte krte ha. Aur Jo apne setpoint set kiya ha usi ke according PICV open aur close temperature maintaine krne ko
Amazing
Psssst,
How to solve P42 output sensorprom
Why this warning alarm not removed
If your sensorprom are not installed. Other opation you can hide.
👍
I have MAG5000 siemens. Want to set Calibration factor but its not show unlock option and its not change. Only Correction factor changed. Plz advise me
Because your sensorprom are reset
Good
Trane yvaa air-cooled chiller displays show vsd communication failure fault what is the problem
send me photos of error communication.
@@INSTRUMENTCONTROLGURUgive me your Watsup number
@@aircooledchilleralltypes4938 +966590423057
Aslk aadil bhai need ur help i am unable to change the node address of sitrans th400 pa transmitter assiging address failed OM parameter invalid error is coming
Bhai need ur whatsapp no
@@ateeqssss49 +966590423057
please send me error photos,so i can try to solve your issue.
Call me on my Whtsapp no
😂
How did you connect the Sitrans to the HMI? Thanks
through profibus PA communication.
Nice
Good job
Thanks
someone knows this app? play.google.com/store/apps/details?id=com.hexapaquete.decimalahexadecimal
Where can I get the software?
Contact with your local area Siemens supplier.
Good Job
ua-cam.com/video/0SqXr_4hikI/v-deo.html
Good one
Thanks
All the best bro👍
Thank you so much 🙂
Very informative, good work bro