- 3
- 44 745
John Kula
United States
Приєднався 5 гру 2014
SM1278 Step By Step Setup
Learn how to set up Siemens 1200 SM 1278 IO-Link from start to finish. Know what software you need to accomplish the tasks and how to wire up the device and sensors. Easy simple step-by-step setup.
You can download the manual by clicking the link below.
support.industry.siemens.com/cs/attachments/65949252/io_link_system_function_manual_en-US_en-US.pdf?download=true
You can download the manual by clicking the link below.
support.industry.siemens.com/cs/attachments/65949252/io_link_system_function_manual_en-US_en-US.pdf?download=true
Переглядів: 6 490
Відео
Populating Siemens Tia Portal array with time sequence.
Переглядів 2,2 тис.3 роки тому
Easy way to auto-populate the array index by using time value. This is helpful if you need to add different values to the array in sequence.
Kepware Setup with the AB PLC via Ethernet
Переглядів 36 тис.4 роки тому
Fast, simple and basic setup of the Kepware Server and the Allen Bradley PLC
thank you
Hi mate, Do we need to do any DCOM config ?
A Nice Job Buddy, Keep it up
Hi, is there a way to sent some tag value with a server client to an url(external) and get comunication between both? note: it could be using a plc getting the data or as simulation of tags but sending the tag value to an api url
Hi Yes however you will need to establish a communication path first on both ends. My suggestion would be NodeJS. That’s actually coming in one of my videos in a near future.
Thank you so much@@johnkula5168
Hi, i just notice a message in kepware event it says Modbus TCP starting unsolicited communication. What does it means
Awesome, congratulations!!!
I was looking a solution like this. thanks John.
Awesome!! I’m happy that I was able to help!
Fantastic Video, thank you
How to download OD102 file for IO-Link ?
If you got to the manufacturers website, they should have one if it’s IO Link capable.
@@johnkula5168 Do you have the Link ?
Great work
So if im writing back to plc thru kepware i need to make a seperate channel for writing
i have one questin that why i cant start device tool
Hi Khanh, Apologies for answering question with a question. Do you get an error? Have you tried running the TIA As admin? Also I would check if you have the right device in a right place.
@@johnkula5168 we always need s7 pct before we can start device tool right ?
@@khanho4827 yes. Make sure you don’t have any errors in the device setup as well
@@johnkula5168 thank you very mụch, 1 follow for you.
@@khanho4827 Any time friend. Hopefully you get it running. If for some reason you run into problems still, let me know and we can take a look at it via zoom.
Very nicely explained
Very clear, thanks!
Holy shit tnaks thanks bro
Edson, you're welcome. I'm glad this has helped you out.
Thanks for explaining so well
Hi Rich, No problem sir. Thank you for watching.
Great demonstration. Thank you
Hi Tyler, Thank you sir. More to come.
This is just right! all the details, very clear. Thank you!
Thank you Michael. You're very welcome!
I am getting a Driver not Started error. Is there a quick fix to this?
Hi Julian . At which point are you getting this error?
@@johnkula5168 I have a guardlogix 5380 controller. After I finish the set up and go to properties in the device and select create tags I get the error. I am using the Allen Bradley Controllogix Ethernet driver with model CompactLogix 5300 family selected
@@julianepps6123 did you solve this problem?
Hi I am getting error "Unable to generate a tag database for device" How can I resolve it
Hi John! Great video!!! Would you have the link to the SM 1278 IO-Link manual? I'm not finding.
Hi Rodrigo, Try going here. support.industry.siemens.com/cs/attachments/65949252/io_link_system_function_manual_en-US_en-US.pdf?download=true I found it by googling " siemens s7-1200 io link manual ". The first result will take you directly to download.
Excellent!!! exactly what I needed! Thank you very much friend.
HI Vadik, Glad it helped! This module can be tricky at times.
Thanks - It was very helpfull.
Anytime Jaka
Thanks for the video. Can you tell me what we need on the AB PLC side? Do we need any kind of OPC DA driver or do we need a certain type of ethernet module.
Hi Melese, On the PLC side all you would need is the program and the IP address to be on the same subnet as the sever. The Kepware will do the rest.
Great video John! Cristal clear explanation. Thank you!
Hi Enrique, Glad you enjoyed it! Definitely more to come. Specially on Siemens controllers.
This video saves me a lot of time to find out how it works... Thank and keep up the good work!
Hi Martinovic, Glad it helped! I agree. Some of those modules can be like opening Pandoras box.
Fantastic. congratulations.
Hi Maicon. Many thanks! I am glad I was able to help with this video.
You made it very easy for anybody to understand. Thank you so much sir
Excellent explanation friend
Thank you William. Appreciate the feedback.
Hey do you have video for Siemens S7 1200 cpu using Ethernet or micrologix 1000 using serial?
Hi Liban Abu. I do not at the moment but the difference between Siemens and Compact logix is that you would need to specify the absolute addressing in the Kepware. At this point I dont think that Kepware has the capability to auto populate tags for Siemens.
thanks a lot John!
You are welcome Edgar. Hopefully it helps.