JSP CIVIL Engineering
JSP CIVIL Engineering
  • 22
  • 469 145

Відео

Introduction and Setting or Temporary Adjustments of Total Station Instrument
Переглядів 8205 років тому
By Prof. V. D. Deshmukh from Civil Engineering Department of JSPM's Jayawantrao Sawant Polytechnic, Hadapsar, Pune-28
Measurement of Horizontal Angle by Direct Method
Переглядів 2,5 тис.5 років тому
By Prof. V. D. Deshmukh from Civil Engineering Department of JSPM's Jayawantrao Sawant Polytechnic, Hadapsar, Pune-28
Measurement of Horizontal Angle by Repitition Method
Переглядів 11 тис.5 років тому
By Prof. G. R. Hole from Civil Engineering Department of JSPM's Jayawantrao Sawant Polytechnic, Hadapsar, Pune-28
Measurement of Horizontal Distance, Horizontal Angle and Vertical Angle by Using Total Station
Переглядів 10 тис.5 років тому
By Prof. V. D. Deshmukh from Civil Engineering Department of JSPM's Jayawantrao Sawant Polytechnic, Hadapsar, Pune-28
Setting a Circular Curve by Offset from Long Chord Method
Переглядів 11 тис.5 років тому
By Prof. P. D. Dandge from Civil Engineering Department of JSPM's Jayawantrao Sawant Polytechnic, Hadapsar, Pune-28
Setting a Circular Curve by Rankine's Method of Deflection Angles
Переглядів 28 тис.5 років тому
By Prof. P. D. Dandge from Civil Engineering Department of JSPM's Jayawantrao Sawant Polytechnic, Hadapsar, Pune-28
Plane Table Surveying by Traversing Method
Переглядів 8 тис.5 років тому
By Prof. P. D. Dandge from Civil Engineering Department of JSPM's Jayawantrao Sawant Polytechnic, Hadapsar, Pune-28
Plane Table Surveying by Intersection Method
Переглядів 10 тис.5 років тому
By Prof. J. S. Shendage from Civil Engineering Department of JSPM's Jayawantrao Sawant Polytechnic, Hadapsar, Pune-28
Plane Table Surveying by Radiation Method
Переглядів 22 тис.5 років тому
By Prof. J. S. Shendage from Civil Engineering Department of JSPM's Jayawantrao Sawant Polytechnic, Hadapsar, Pune-28
Determination of Standard Consistency of Ordinary Portland Cement OPC
Переглядів 4975 років тому
By Prof. A. E. Tamboli from Civil Engineering Department of JSPM's Jayawantrao Sawant Polytechnic, Hadapsar, Pune-28
Determination of Initial & Final Setting Time of Ordinary Portland Cement OPC
Переглядів 1,4 тис.5 років тому
By Prof. G. S. Desai from Civil Engineering Department of JSPM's Jayawantrao Sawant Polytechnic, Hadapsar, Pune-28
Determination Silt Content in Sand as Per IS 2386
Переглядів 10 тис.5 років тому
By Prof. R. P. Wade from Civil Engineering Department of JSPM's Jayawantrao Sawant Polytechnic, Hadapsar, Pune-28
Determination of Fineness Modulus of Fine and Coarse Aggregates by Sieve Analysis
Переглядів 17 тис.5 років тому
By Prof. G. S. Desai from Civil Engineering Department of JSPM's Jayawantrao Sawant Polytechnic, Hadapsar, Pune-28
Determination of Fineness of Cement by Sieving Method
Переглядів 3925 років тому
By Prof. A. E. Tamboli from Civil Engineering Department of JSPM's Jayawantrao Sawant Polytechnic, Hadapsar, Pune-28
Determination of Bulk Density of Coarse Aggregates
Переглядів 39 тис.5 років тому
Determination of Bulk Density of Coarse Aggregates
Determination of Turbidity of Water Sample by NephloMeter
Переглядів 100 тис.5 років тому
Determination of Turbidity of Water Sample by NephloMeter
Determination of Total Dissolved Solids (TDS) of Water Sample by Digital TDS Meter
Переглядів 10 тис.5 років тому
Determination of Total Dissolved Solids (TDS) of Water Sample by Digital TDS Meter
Determination of Residual Chlorine of Water Sample by using Chloroscope
Переглядів 28 тис.5 років тому
Determination of Residual Chlorine of Water Sample by using Chloroscope
Determination of Dissolved Oxygen in Water Sample by Digital DO Meter
Переглядів 9 тис.5 років тому
Determination of Dissolved Oxygen in Water Sample by Digital DO Meter
Determination of Optimum Dose of Coagulant Alum for given Water Sample
Переглядів 21 тис.5 років тому
Determination of Optimum Dose of Coagulant Alum for given Water Sample
Determination of PH of Water Sample by Digital PH Meter
Переглядів 127 тис.5 років тому
Determination of PH of Water Sample by Digital PH Meter

КОМЕНТАРІ