- 251
- 84 139
Technical_Skills
Algeria
Приєднався 10 кві 2022
TRX Degraded issue
TRX Degraded issue, learn about common causes, symptoms, and simple troubleshooting steps to resolve the issue.
Переглядів: 82
Відео
Ericsson Baseband 66XX Onsite integration
Переглядів 5725 місяців тому
Welcome to our in-depth guide on Ericsson Baseband Onsite Integration! In this video, we walk you through the intricate process of integrating Ericsson baseband units seamlessly into your network infrastructure. #dwdm #roadm #vswr #Telecom #baseband #integração #restore #Ericsson #Conhecimento #Baseband_Integration #moshell #dus #bts #4g #3g #dug #duw #ericsson #juniper #Cygwin #baseband #DUW #...
Moshell 24.0a Installation Guide: Step-by-Step from Scratch
Переглядів 3,9 тис.10 місяців тому
The "Moshell 24.0a Installation Guide: Step-by-Step from Scratch" video provides a comprehensive tutorial on installing Moshell version 24.0a. The video takes users through the installation process, starting from the basics and guiding them step-by-step to set up Moshell from scratch. Throughout the tutorial, viewers can expect to learn about the system requirements, download and installation p...
BaseBand Ericsson : Guide to Physical Factory Reset
Переглядів 1,1 тис.10 місяців тому
BaseBand Ericsson Factory Reset Physically #Router #routers #cisco #telecommunication #networking #network #IT #DUS #juniper #routers #juniper #junos #baseband #ml_tn #moshell #moshell #bb #alarm #bb6630 #bts #dug #duw #DUS #router #ericsson #zte #nokia #DWDM #PSS #IP #transmission #DirectionRéseau #lamiseenréseau #Genévrier #telecom #telecommunicationengineering #telecommunication #telecombill...
Perform a Juniper MX/EX/SRX/QFX Router Chassis Health Check
Переглядів 43911 місяців тому
In this video tutorial i have covered the topic on how to perform a quik health check on your Juniper Network EX/SRX/MX or QFX Router. The following commands have been used in the video: - show version - show chassis craft-interface - show chassis led - show chassis environment - show chassis routing-engine - show system storage - show chassis alarm - show system alarm - show interfaces descrip...
Juniper router MX chassis
Переглядів 36611 місяців тому
#routers #juniper #junos #baseband #ml_tn #moshell #moshell #bb #alarm #bb6630 #bts #dug #duw #DUS #router #ericsson #zte #nokia #DWDM #PSS #IP #transmission
Technical_Skills Youtube Channel #DUW31 #BaseBand #ML6000 #ML_TN #Moshell
Переглядів 553Рік тому
Technical_Skills UA-cam Channel #DUW31 #BaseBand #ML6000 #ML_TN #moshell #MiniLinkTN #MiniLink_TN #MLTN #ML_TN #ML_6000 #Ericsson #Transmission #Telecom #Telecommunication #MiniLink #RBS #BTS #RBS6000 #Baseband #BB #BB6630 #DUW #DUG #External #alarm #moshell #juniper #nokia #PSS #DWDM
Reconfigure External Alarm Ports DUW 3G
Переглядів 278Рік тому
Reconfigure External Alarm Ports DUW 3G get alarmport slogan get HwUnit=SAU-1,AlarmPort=2 set Equipment=1,HwUnit=SAU-1,AlarmPort=2 administrativeState 0 set Equipment=1,HwUnit=SAU-1,AlarmPort=2 alarmSlogan High Temp set Equipment=1,HwUnit=SAU-1,AlarmPort=2 normallyOpen false st alarmport #MiniLinkTN #MiniLink_TN #MLTN #ML_TN #ML_6000 #Ericsson #Transmission #Telecom #Telecommunication #MiniLink...
Configure External Alarm DUW 3G
Переглядів 178Рік тому
Configure External Alarm DUW 3G gs crn Equipment=1,HwUnit=SAU-1 administrativeState 1 piuType PiuType=SAUSS000_* position 0 positionInformation positionRef Cabinet=1 userLabel end gs- gs crn Equipment=1,HwUnit=SAU-1,AlarmPort=1 administrativeState 1 alarmInExternalMe false alarmSlogan Mains _failure normallyOpen true perceivedSeverity 4 probableCause 550 userLabel end crn Equipment=1,HwUnit=SAU...
Configuration du lien de transmission Mini Link TN Ericsson Partie4
Переглядів 173Рік тому
Configuration du lien de transmission Mini Link TN Ericsson Partie4
Configuration du lien de transmission Mini Link TN Ericsson Partie3_Packet Link
Переглядів 241Рік тому
Configuration du lien de transmission Mini Link TN Ericsson Partie3_Packet Link
Configuration du lien de transmission Mini Link TN Ericsson Partie2
Переглядів 220Рік тому
Configuration du lien de transmission Mini Link TN Ericsson Partie2
Configuration du lien de transmission Mini Link TN Ericsson Partie1
Переглядів 494Рік тому
Configuration du lien de transmission Mini Link TN Ericsson Partie1
Deal with the alarm Loss of main hardware unit HwUnit=PSU 1 (commercial power failure).
Переглядів 166Рік тому
Deal with the alarm Loss of main hardware unit HwUnit=PSU 1 (commercial power failure).
Block, Restart and deblock radio Unit RUS or RRU
Переглядів 135Рік тому
Block, Restart and deblock radio Unit RUS or RRU
LTE Network Planning Huawei Technologies
Переглядів 148Рік тому
LTE Network Planning Huawei Technologies
Ericsson Network Statistics Display for EPC
Переглядів 67Рік тому
Ericsson Network Statistics Display for EPC
Ericsson Software Hardware Manager, Import a Software Upgrade Package
Переглядів 150Рік тому
Ericsson Software Hardware Manager, Import a Software Upgrade Package
Dear sir please upload video on DWDM KPI PARAMETER
Williams Gary Johnson Michael Hall Daniel
Nice..👍
Excellent & precision detail explanation with perfection… these type of materials I was looking on Internet since sometime ….. Today Finally found it in form of your channel\Playlist. Thank you for your immense hardwork.
bien explique merci
Selling
I have two of these
Nicely explain each and every component of DWDM
Good 👍 and perfect teacher I need more tutorials
Greetings interesting contact please
👍👍👍👍
Taken video from engineering funda
Thanks 😊
Very nicely explained. very clear fundamentals
verry good
What wave is used on backup?
Good stuff, this was helpful thank you.
@Technical_Skills This video is made by me and uploaded at my channel . Thanks for uploading it in your channel . I appreciate your interest & also like your channel videos 👍
Thanks
Relié avec pss
Thanks to share
As ponteiras estão no local correto?
Where it's?
My god bless you
Thank you, very good presentation
Merci pour l'effort fourni.
Baraka allah fik, kayen des logiciel de simulation pour s’entraîner sur les commandes ? Pour les étudiants par exemple qui ont pas d’accès aux équipements des télécommunications.
Vous pouvez utiliser Cygwin/Moshell sans connexion avec les équipements offline.
ربي يبارك فيك وفي من رباك❤
@@technical_skills5625 comment ça ? apprendre les commandes Linux vous voulez dire ?
hi i have problem crn Equipment=1,FieldReplaceableUnit=SAU-1,AlarmPort=3 administrativeState 1 alarmInExternalMe false alarmSlogan BATTERY FUSE-SPD ALARMS normallyOpen true perceivedSeverity 4 userLabel end Please enter each attribute on a separate line in the format "<attributename> <value>". Type "end" to commit or <enter> to abort.
just copy and paste the script confb+ gs+ crn Equipment=1,FieldReplaceableUnit=SAU-1,AlarmPort=3 administrativeState 1 alarmSlogan BATTERY FUSE-SPD ALARMS normallyOpen true perceivedSeverity 4 userLabel end confb- gs-
What's the reference for good XPI Value?
Different antenna types have different XPI values for example: Standard antennas: 25dB < XPI < 30dB High performance antennas: 30dB < XPI< 35dB improved HP antennas: 35dB < XPI < 40dB Ultra high performance antennas: 30dB < XPI < 40dB Super high performance antennas: > 40dB
@@technical_skills5625 what to do if XPI 6-7 dB?
@@dark-vibe1703 we do Polarization adjustment or XPD Alignment
❤
How to change "operationalstate" to enable or disable in alarm
You can't change the operationalstate it is read only attribute, but to Enable or Disable the alarm you need to Locked or Unlocked the administrativeState.
merci 🌷🌷
Thank you !! Very well explained.
Salut monsieur, pouvez-vous m'aider à résoudre un exercice de microprocesseur8086
avec plaisir
@@technical_skills5625 Merci monsieur, j'ai besoin de votre email pour vous contacter
@@AhmedAhmed-gl4mg zmenani@yahoo.fr
@@technical_skills5625 Merci monsieur je vous ai envoyé un message sur votre e-mail
@@AhmedAhmed-gl4mg voir le video : ua-cam.com/video/gPLZ9nCxFBo/v-deo.html
merci
You're welcome
please share presentation
I tried this method but when I see st SAU the (operational st) is disabled and when I try to set it enable it say this value is read only What is wrong?
It's like the bb couldn't see scu and sau
SAU 01 01 SCU 01 01 SHU 02 01
@@ragnarloth4613 Can you send me dcgk dump file to check your config @ zmenani@yahoo.fr
Thanks❤️ i want to ask how you log to offline node, what's the zip file you moshell it first?
Salam Hocine Ali, to connect offline you should collect logs/Dumps from online Node by using l+ kget all l- or zip file by cmd dcgk
Salam my friend, I'll try that, thank you 🍀
@@HusseinAli-yu6voyou are welcome after collecting the log or Dump (zip file) 1* copy and paste the log into your home directory 2* Moshell to the log name with extension
@@technical_skills5625 🍀🍀
@@technical_skills5625 my friend sorry for questions, but in case defining external alarms on baseband inside RBS6102, when physical alarm path is: ovp alm.. SAU.. SCU... SHU,, to EC port of BB5212, what can we do?
P𝐫O𝕞O𝓢m 👊
SAU MO creation confb+ gs+ crn Equipment=1,FieldReplaceableUnit=SAU-1 administrativeState 1 isSharedWithExternalMe positionCoordinates positionInformation positionRef Cabinet=1 userLabel end confb- gs-
Alarm port creation confb+ gs+ crn Equipment=1,FieldReplaceableUnit=SAU-1,AlarmPort=1 administrativeState 0 alarmSlogan Mains failure normallyOpen false perceivedSeverity 3 userLabel end crn Equipment=1,FieldReplaceableUnit=SAU-1,AlarmPort=2 administrativeState 0 alarmSlogan High Temperature normallyOpen false perceivedSeverity 2 userLabel end deb alarmpor cvms ExternalAlarm confb- gs-
hi, but that is when you will use the SAU port, in case that you will use port 1 and port 2 of external alarms, its the same process?
@@Israeljgg yes The Baseband unit supports eight external alarms, four per port. you define these ports as below gs+ crn Equipment=1,FieldReplaceableUnit=1,AlarmPort=1 administrativeState 0 alarmInExternalMe false alarmSlogan filterAlgorithm 0 filterDelay 60 filterTime 0 normallyOpen true perceivedSeverity 4 userLabel end gs-
يعطيك الصحة