- 50
- 454 609
Chris Ambidge
Приєднався 22 сер 2014
326 - T5 Phosphoric Acid Dissociation
0:07 Phosphoric acid dissociation
2:22 Calibrating the calorimeter
7:05 Measuring energy from chemical reactions
7:31 Getting bulk solutions
8:33 Titrating to get NaOH concentration
10:32 Calorimetry
15:32 Cleanup
2:22 Calibrating the calorimeter
7:05 Measuring energy from chemical reactions
7:31 Getting bulk solutions
8:33 Titrating to get NaOH concentration
10:32 Calorimetry
15:32 Cleanup
Переглядів: 1 748
Відео
204 - Infra Red 1 - Liquid Sample and Runing FTIR
Переглядів 3,9 тис.9 років тому
204 - Infra Red 1 - Liquid Sample and Runing FTIR
204 - Infra Red 2 - Solid Sample Prep
Переглядів 1 тис.9 років тому
204 - Infra Red 2 - Solid Sample Prep
326 - E2 Membrane Diffusion
Переглядів 2479 років тому
0:08 Membrane diffusion 0:57 Inside the cell 3:05 How the analysis works 5:25 Performing the experiment - conditioning the cell 6:29 Agitating the cells 7:05 Setting up diffusion, and analysing results 8:50 Cleanup
326 - E2 Diffusion Through a Membrane (Rocker and Agitator)
Переглядів 899 років тому
326 - E2 Diffusion Through a Membrane (Rocker and Agitator)
204 - Spectronic 20 and Calibration Curve
Переглядів 11 тис.9 років тому
204 - Spectronic 20 and Calibration Curve
326 - T2 Batch Calorimetry with Solid Reactants
Переглядів 4119 років тому
326 - T2 Batch Calorimetry with Solid Reactants
Safety Video 1 - Physical Facilities in LM113-117
Переглядів 2,4 тис.9 років тому
Safety Video 1 - Physical Facilities in LM113-117
Safety Video 3 - Acting Safely in a Lab
Переглядів 3,7 тис.9 років тому
Safety Video 3 - Acting Safely in a Lab
Safety Video 2 - Personal Safety Equipment
Переглядів 2,3 тис.9 років тому
Safety Video 2 - Personal Safety Equipment
326 - E3 Electrochemical Fuel Cell
Переглядів 2,4 тис.10 років тому
326 - E3 Electrochemical Fuel Cell
326 - K3 Kinetics of Iodide/ Peroxydisulphate Reaction
Переглядів 5 тис.10 років тому
326 - K3 Kinetics of Iodide/ Peroxydisulphate Reaction
326 - K1 Kinetics of Ester Hydrolysis
Переглядів 51 тис.10 років тому
326 - K1 Kinetics of Ester Hydrolysis
326 - K2 Kinetics of Sucrose Inversion
Переглядів 12 тис.10 років тому
326 - K2 Kinetics of Sucrose Inversion
What about the drops of water that are above the meniscus on the walls of the flask? Will it not change the concentration when inverted?
Excuse me, Sir. May I ask about if weighing with an analytical balance whether it is necessary to balance before the weighing paper is inserted or after the weighing paper is inserted ?
thanks for the video...it's really helped me a lot
Thank you sir I am from india 🇮🇳🇮🇳🇮🇳
Such a helpful video, thanks!!
👍🏻
dear sir u have done a unsafe work ..rpm should be zero before open a lid
disliked
Vacuum grease can be sparingly applied to the glassware joints to make sure extra vapor doesn't escape.
Jel ima koga iz 3.b FT?
Fala kume da nije bilo tebe pao bi biohemiju
Idrugi pumt
Gibberish
@@jackmarentette1302 not out problem u dont speak croatian hehe
Ivan Škojo you’re the problem here
@@jackmarentette1302 wow! Well that's rude! They should have taught you better in your indian schools how to talk to other people. You should be ashamed of yourself. I hope you'll think about what you've done.
okay so I'm new to this and I was wondering why is it always demonized water that goes in to fill to the line?? what if you want to measure two liquids??
Deionized water is just the solvent for the solute, this solute can also be a liquid. A volumetric flask is not used to just measure the volume of a liquid, it is used to prepare a solution in which it is exactly known how much solute is present (can be liquid or solid) in that volume of the solution. Of course you could use other solvents than deionized water as it will depend on what you want to dissolve. Hope this is clear as I don't know your background on these kind of subjects.
3:12 ... How come we used to balanced session , That you hold the centrifuge continuously .
Thank you!
Hala nitingog
Hay
Nice thanks a lot
Thanks for your useful teaching how to use pipette. But I have a little question that Why do not we blow out the liquid at the tip. If we do blow, what will effect to the result? Thanks again!
Yes. The pipettes are calibrated so that that little amount should not be included in the aliquot. If you were to add that little amount of liquid into your receiving vessel, then the measurement of the solution would be too high.
@@taylorhogue316 Thank you so much
Also check your pipette if there's a TD marker on it .it means to deliver only.
morehead!
me too
Very thorough. Thank you.