CabComfort Direct
CabComfort Direct
  • 1
  • 10 680
Espar D2/D4 Air Heater Maintenance Procedures
This video has some tips on the Espar D2/D4 maintenance procedures, which includes maintaining the atomizer screens & fuel filters. It also has information on smoking issues.
Переглядів: 10 712

Відео

КОМЕНТАРІ

  • @danmarvin3612
    @danmarvin3612 Місяць тому

    Excellent presentation, ty

  • @craigj6277
    @craigj6277 Місяць тому

    About how many hours of running until replacement of these filters is needed? Also, how often should I run my heater during the summer so the fuel filter doesn’t get gummed up?

  • @Senior62
    @Senior62 3 місяці тому

    Good video. I’m having a different problem. The control unit screen is lit but blank. Just started doing this. Any idea?

  • @rmjryost
    @rmjryost 8 місяців тому

    Where’s you source for the 12mm slotted socket?

  • @GaryBoyd02
    @GaryBoyd02 9 місяців тому

    Great video thanks!

  • @nonemauro
    @nonemauro Рік тому

    My control unit is held down by three screws, not one. And the screws are five point screws. Also the igniter is not attached as a separate piece, it’s attached to a hub that goes to the wire harness. I managed to unscrew the igniter, but the wires kept twisting since I could not detach the igniter from the hub. I successfully replaced the atomizer screen and reassembled everything. Would be nice if an updated video was available for the newer Airtronic D2 S2.

  • @ryanroads7748
    @ryanroads7748 Рік тому

    The socket can be reused...at least mine is.

  • @darylhawkins4658
    @darylhawkins4658 Рік тому

    Sadly this video isn’t much help as I have a Generation 2 D2. It requires a TE-Connectivity type removal tool to extract the glow plug pins out of the connector.

  • @chuckybennett4947
    @chuckybennett4947 3 роки тому

    I don't know how this video has so few views/likes. I've serviced my own d2 heater multiple times and this time around I'm getting white smoke billowing. I'm going to re-check the things described here. Best info I've found! Thanks so much! Please make more!

    • @jeremyhanna3852
      @jeremyhanna3852 2 роки тому

      It was getting smoke and no start so I tore it down cleaned everything replace the ignitor and screen put new gaskets in it was 3.5 yrs old at the time worked about a week didn't see any visible smoke took right off sounded fine a week later no work I cleaned everything again right full of carbon new gaskets put it back together and today it stopped again looked in exhaust with scope its right full of carbon again any ideas where I'm going wrong

    • @alexk5411
      @alexk5411 2 роки тому

      @@jeremyhanna3852 have you replaced the fuel filter? Enough anti-gel additives in fuel I’d expect?

    • @jeremyhanna3852
      @jeremyhanna3852 2 роки тому

      @Alex K it's fixed I replaced the hole burn chamber

    • @alexk5411
      @alexk5411 2 роки тому

      @@jeremyhanna3852 thanks for letting me know. I’m thinking of replacing mine if cleaning with acetone brings no effect.

    • @nonemauro
      @nonemauro Рік тому

      My control unit is held down by three screws, not one. And the screws are five point screws. Also the igniter is not attached as a separate piece, it’s attached to a hub that goes to the wire harness. I managed to unscrew the igniter, but the wires kept twisting since I could not detach the igniter from the hub. I successfully replaced the atomizer screen and reassembled everything. Would be nice if an updated video was available for the newer Airtronic D2 S2.

  • @thomaswestby7926
    @thomaswestby7926 5 років тому

    Great job explaining the service

  • @dos-trotamundos
    @dos-trotamundos 5 років тому

    Where are you located? Can i go to your place to give maintenance to my heater? 305 487 2194 Message me please.