package Ac compressor change, Ac compressor kasy change kary
Переглядів 1355 місяців тому
package ac 12.5 tone compressor change
water chiller installation water cooler easy lgaty han
Переглядів 2,6 тис.6 місяців тому
water chiller installation water cooler easy lgaty han
transfer noisy outdoor units from balcony
Переглядів 172Рік тому
transfer noisy outdoor units from balcony
compressor change tips for new technician
Переглядів 272Рік тому
compressor change tips for new technician
leak find and repair Ac Evaporator coil
Переглядів 1592 роки тому
leak find and repair Ac Evaporator coil
4ton AC pump down pipe readjust @Ahmedac5
Переглядів 4502 роки тому
this video about how to pump down 4 ton Air conditioner
discharge pressure high and suction in vacuum repair #ahmedactech
Переглядів 3502 роки тому
this video about AC repair
3.5ton single phase compressor change #ahmedactech
Переглядів 5372 роки тому
this video about how to check and replace a compressor #acmaintenance #ahmedactech #acrepairing #hindi #urdu
2ton AC repair leak top-up R410a
Переглядів 2862 роки тому
this video about how to top-up r 410a#ahmedactech #acmaintenance #acrepairing
Lp switch wire cut pipe repair leak charge gas
Переглядів 1752 роки тому
Lp switch wire cut pipe repair leak charge gas #ahmedactech #acmaintenance #acrepairing #urdu #hindi
temperature 16 lekin cooling Nahin #ahmedactech
Переглядів 872 роки тому
temperature 16 lekin cooling Nahin #ahmedactech
contractor high amp's burn repair #ahmedactech
Переглядів 2672 роки тому
contractor high amp's burn repair #ahmedactech
starting capacitor aur relay ki wiring kasy kary#ahmedactech
Переглядів 3812 роки тому
starting capacitor aur relay ki wiring kasy kary#ahmedactech
E4 error sensor check repair #ahmedactech
Переглядів 1742 роки тому
E4 error sensor check repair #ahmedactech
4 ton 3 phase AC installation wiring #ahmedactech
Переглядів 1,3 тис.2 роки тому
4 ton 3 phase AC installation wiring #ahmedactech
Repair E4 and readjust bad installed out door unit #ahmedactech
Переглядів 2442 роки тому
Repair E4 and readjust bad installed out door unit #ahmedactech
duct Ac ki full water service #ahmedactech
Переглядів 802 роки тому
duct Ac ki full water service #ahmedactech
Repair bad installed duct Ac difficult fault finding #ahmedactech
Переглядів 2562 роки тому
Repair bad installed duct Ac difficult fault finding #ahmedactech
York 4ton duct Air-conditioner blower motor repair #ahmedactech
Переглядів 1372 роки тому
York 4ton duct Air-conditioner blower motor repair #ahmedactech
2 ton AC repair and clean #Ahmedactech
Переглядів 3352 роки тому
2 ton AC repair and clean #Ahmedactech
AC repair tips Urdu/Hindi Keep clean behind the outdoor #Ahmedactech
Переглядів 1072 роки тому
AC repair tips Urdu/Hindi Keep clean behind the outdoor #Ahmedactech
high amp's compressor trip problem solved #ahmedactech
Переглядів 9602 роки тому
high amp's compressor trip problem solved #ahmedactech
install shower glass in bathroom Hindi/Urdu#ahmedactech
Переглядів 1102 роки тому
install shower glass in bathroom Hindi/Urdu#ahmedactech
OGeneral window AC remote control Hindi/Urdu #ahmedactech
Переглядів 2,4 тис.2 роки тому
OGeneral window AC remote control Hindi/Urdu #ahmedactech
Assalamualaikum Bhai central Ac compressor compressor kharab hi R407C gas hi per abhi jo compressor new Lagana hi R22 hi kya ye gas chalega ki same to same gas Wala compressor dalna padega please reply me
Wa alikum salam g brother chal jye ga ap ny liquid line ka filter b change krna hai aur vacuum kar k gas change krna
Bro apko wire k agey u type thimble lgana chaheay very Bad
G ap ny thik kaha kabi kabi kam juldi ho tu asay lga dety han
@@Ahmedac5 shukria
Bhai package ac R22 suction 60 discharge 300 cooling nhi kr rha Cooling coil bhi thanda ho rha h kya dikkat ho sakta h bhai
@@aaryan3806 65 tak kar dain aur make sure k evaporater coils clean han aur supply aur return duct main kahin leakage tu nai
@@aaryan3806 room temperature kitna set kia apny
@@Ahmedac5 Bhai 20 set Kiya h
Aslamoalikom bro ma ne 5ton ac ma gass charge ki to wo vequm ma ja k Trip kar jata ha kiya problem ho sakti ha please bata dena msg ma shortly
Uska filter blocked hai nai tu indoor orifice piston b blocked ho skta hai
Konsa brand ka ac hai
First ap asa karo l n key bnd kar k section line se pressure dy kr check Karo discharge main same pressure waps ata hai tu pipe aur indoor main problem nai phir filter dryer blocked ho ga
@@WajidHussain-dv8rd ua-cam.com/video/_n7xEFa4xks/v-deo.htmlsi=mZJD6B62FRU5My4p ( ye video ap dhek lo
❤❤❤❤
Thanks 😊
Thanks 😊
Bhai package LG ka hai compressor kharab ho gaya hai new Laga na hai toh kya Flashing kerna hi Kya our kitne number gas se flash kerna hai
Kitny ton ka hai aur jab aski gas release Karen gym tu slowly karni hai ta k purny compressor ka oil agy na jy phir flashing ki zarort nai bus liquid line filter change Kar dena ap
Wesy flashing k like hmm 141b use karty han
@@Ahmedac5 14 b Kya Bhai full likho
12 number bhi ata hi kya Flashing ke leye
@@Ahmedac5 filter Cooper ka Laga hai 3 ench ka original same to same nahi melega ager main flashing ker de nahi change kare toh koi problem toh nahi Hogi
Vai jan York ka pakeg 25 ton ka AC hai zr 190 ka kmpershr fit Kiya lekin section line me 100 discharge line mein 120 dekha Raha hai calling Nahin a raha hai
Brother liquid line filter b change kia ap ny expansion valve b iska check Karen jahan evaporator ki capillary han us pehly expansion hole bnad ho skta hai
Bhai ji aur ka 25 ton ka AC hai discharge pressure 120 dikhata hai section 100 dikhata hai kya reason ho sakta hai bhai ji
Bhai ji ek sawal aur hai zr 190 ka compressor fit Kiya do compressor cooling karta hai teen compressor section line se Hot 🔥 hota hi bhai ji kya reason ho sakta hai
@@nandarairi9870 3 phase ko ap check Karo connection R Y B compressor roution
@@Ahmedac5thanks Vai jan ❤
From where i get that pcb board?
I AM in Qatar which city you belong I think it's available in Pakistan all big cities
@@Ahmedac5 Lahore
@@harismunir2638 phir wah SE easily apko mil jy ga ap Google search kr ly
Mashallah good job sir thank ❤
Thanks 👍
Recip compressor consumes more energy but very reliable and longevity than rotary and better cooling
Yes, true thanks for your valuable comment
Yeah boy
Thanks
Aiwaaaa
Thanks
Nice information ❤
Thanks
Vekap kitna dalata hai or likwid kitna dalata hai ye batao
Pure refrigerants like R22 can be added in liquid or vapor states,R22 or R134a you can charge either way. I charge via liquid for larger volumes (lbs) and vapor for smaller volumes (oz)
Sir ya kaha re mily ga or price
Kisi b AC spares parts ki shop s mil jye ga price yahan Qatar main 25 riyal hail
sir hmara unit me kndenshr me likij he oyl sa he vha pr pr mil nhi rhi R 22se hm ne cek krrhe he 100 ka preshr dal kr pta nhi lg rha hm nitrojn dal kr 200 preshr se cek kr le compreshr sistm se hta kr kre ya sistm me com preshr lge lge nitrojn se btana sir
200psi tak dy sktay Han .aur condenser main jahan oil hai wahan se fins hata k check Kar ly
Yea genarel ac
Yes
masha ALLAH malik sb
Thanks
Aap ka samjhane ka tarika sahi nhi hai bhai agli video sahi se banao
Ok thanks next try karu ga
Nice
Thanks
Nice
Thanks
Nice
Liquied lind closed systom ruing and liquiex lind valvd slenkeuly colsed gauge fixed susion gaugd fixe guge 0comeing sushion vslve closed ok after rrparinv indoor relochion ok reparinv ok ok pumpdosn systom ok
Darood pak pr ly
Model no kia ha ?
Model (RUA-30AT3S)
Sir hamara 1.5 ton ka ogeneral ka ac hai. Use kai din baad chalane ke baad phle to sab kuch shi chl rha tha compressor bhi chal rha tha. Fir hmne uski service ki pani se. Tabse se uska compressor nhi chal rha. Jab compressor chalne wala hota hai eek dum se voltage drop hota hai bhot jyada aur fir stabilizer cut maar deta hai. Service man ko dikhaya to voh compressor khrab btaya. Aap koi solution btao. Kyuki dhone se compresor khrab hota hai jya
Ap ka AC inverter hai ya non inverter ? Ager non inverter hai aur stuck hai tu ap technician ko bolain us main hard starter capacitor LGA k dhekhy .
@@Ahmedac5 sir voh ac 10 saal purana hai technician ko bulake dikhvaya to usne capacitor wagera change krke dekha tha tabb bhi nhi chala tab usne kha compressor khrab hai. Non inverter ac hai
@@Shivank8015 capacitor k sath aik 100 MFD ka hard starter laga k check kar skty Han ager stuck hai tu zada torque Milne se shayd chal jye aur ager uski winding kharab hai tu phir apko change he Karna ho ga
放什么药水清洗铜喉的?
English plz my translation not working
Lekin leakage Kahan find hue gas top up karna sirf coustomer ko bewkuf banana hota hai
Bhai video Puri nai dheki ap ny main ny Kaha k piston Ulta laga tha jiski whaja se gass pressure sai nai tha USKO sedha kia video Puri dhek Lyn aur ye hmari boss ki building hai complaint ati hai tu ham repair karty Han yahan bewquf bnaby wali koi BAAT nai
Suction 35psi discharge 350psi which gas indicate...?
Bro it's 55 to 65 it's r22
R22 unit ruing bai expables ba stard cherging 60 ps gulf ok 50to60bsi
75 nahi 65 psig rakko
Thanks
If the system had R-22, the vapor pressure would be between 58 to 85 PSIG but these pressures will be dependent on the wet bulb temperature inside the building and the ambient temperature outside the building
Iam working at saudi arabia 10 years, just u 65 psig don't work wrong
Bhai o general ac ampere 5 le raha hai kiya sahi hai same aisa hi hai
Kitny ton ka hai ager 1.5 hai tu gas Kam ho ga Thora sa top-up karo
@@Ahmedac5 bhai jaisa aap kar rahe waisa hi hai
@@saddamhussain85154 ok gas pressure Kitna hai
@@Ahmedac5 kuch nahi hai khali hai
@@saddamhussain85154 gas puri ho gi Tu amps pury ly ga 11 ya 12 tak agr 2 ton hai Khali itny hi amps let's hai
Bhai agar 2 compressor hai AUR Ek compressor kharab ho gaya to Kya gas dono compressor ka niklana padega ya Jo compressor kharab hai vahi compressor ka gas nikalna padega plz eske uper video banao AAP plz
Jo kharab hai bus uska gas hi nikalna ho ga 2nu compressor ka Alag cooling cycle hai
Bhai ji invater ac hota hai us ka bhi comprassor stop. Ho jata hai
Bro ap m smja ni apki BAAT APK pas inverter AC ka fault hai k stop ho jata hai .ya ap Puch Rahy Han k wo b LRA stuck HOTA hai
@@Ahmedac5 ha mai. Inverter ac hai khbi to kya hota hai 24 pr ac chal rha hai room ka. Tampracher 24 aa jata hai to amp 1.4 ho jate hai or kai baar comprassor of ho jata hai
@@AmitSharma-cu3jb g inverter compressor main variable speed HOTA hai jab temperature Bharat hai tu speed Bharat hai aur tmp com HOTA hai tu speed aur amps Kam ho jata hai
@@Ahmedac5 hai bilkul amp kam ho jate hai But comprassor of bhi ho jata hai kya ye mai janna chta hu
@@AmitSharma-cu3jb ji bilkul off nai HOTA speed bht Kam ho jata hai aur uska sound b ni ata amps b 1 .5 tak a jaty Han aur jesy Garm ho ga room uski speed aur amps barh jyn gy
Sir capillary tube size kya laga hai isme
Bro 0.070 and it's length 30 inches
Badi pyari jgha hai
Thanks
Packeg a c main gass charg ni kr sakty kya
G Kar sktay Han lekin is main kuj leakage ki wajha se welding ki thi jo pehly gas thi thori bht wo Nikal k phir vacuum Kar k charge Kia tha
Ye Saman Pakistan may mil jay gay ya nhi ?
Han g Lahore ya pindi se
Bhai gas charging time kisme Karna hei suction discharge
Suction line main
Sir capillary tube size kya laga hai is ac me
Iska size 0.70 mm hai
@@Ahmedac5length kitni.hai
@@tarunyadav1721 28 inches
Bhai assalamu alikum ... Mujhe bhai bahar aaana hai kuwet ya qatar best konsa ragenga ..
Kuwait ka visa ager mil jye tu wo zada Acha hai wahan ki currency ki value b zada hai
Kitni ton kah AC hae isuk water chiller kah tank kitni liter hae
2.5 ton aur 2500 liter ka tank hai
Helpful brother always practical video uploaded Kare brother
Thanks
Best h
Thanks
Apne kun sah country meh rethae?
Bro main Doha Qatar main HOTA hu
Is unite kah ducting gril ke baremeh ake video uploaded Kare brother kece kum karta hae
Ok in sha Allah
Brother apne always practical video uploaded Kare brother
Thanks alot God bless you and your parents
Thank you ❤️
Kitni ton kah AC hae?
3.5ton single phase
Sir 3.5 ton ka compressor 3 p hota hai
Ye single phase hai
Gjb 👌👌
Thanks 👍