MOV Limit Switch Maintenance
Using a tumbler map to set the MOV timing. Uses an L120 for demonstration.
Переглядів: 1 613

Відео

Control Valve Actuator Removal
Переглядів 2,4 тис.2 роки тому
Uses the actuator force to disconnect the actuator yoke from the valve yoke boss. Fisher Reverse Acting Actuator. Back To The Wood by Audionautix is licensed under a Creative Commons Attribution 4.0 license. creativecommons.org/licenses/by/4.0/ Artist: audionautix.com/
Excel Data Import with Scrolling Trendline
Переглядів 4032 роки тому
Importing raw data and building trend lines for data analysis.
Coax Connector Protector Kit Bently Nevada
Переглядів 8 тис.3 роки тому
Protective boot installation for coax cables.
Actuator Leak Test
Переглядів 11 тис.3 роки тому
Performing a leak test and locating leaks on a Fisher Spring & Diaphragm Actuator.
Excel Conditional Formatting Probe Test Worksheet
Переглядів 6 тис.3 роки тому
This video gives detailed instruction on how to input the formulas necessary to create an auto-calculating form with pass/fail conditional formatting.
Vibration Probe and Cable Ohm Check, Bently Nevada
Переглядів 56 тис.3 роки тому
This video demonstrates one of the methods used to verify the integrity of a coax cable and probe. It can also be used as a quick method for verifying the extension cable length. This video is in reference to a vibration monitoring system, but can be used for any instrument using a coaxial extension cable.
DeltaV CIOC Rack Assembly Hard Core Henry Style
Переглядів 9373 роки тому
A quick look at the process of assembling a DeltaV Electronically Marshalled CIOC column. One Handed Assembly.
Burner Management Flame Detection Viewing Head
Переглядів 6393 роки тому
This video covers the configuration of gain/filtering parameters for a flame scanner/viewing head.
Reverse Action Control Valve Bench Set Test
Переглядів 19 тис.4 роки тому
How to test the "bench set" and make adjustments to the spring tension of a reverse action spring and diaphragm actuator.
Direct Acting Control Valve Bench Set Adjustment
Переглядів 35 тис.4 роки тому
An example of how to test and adjust the "bench set" of a spring and diaphragm actuator without removing the actuator.
Vibration Monitoring Proximity Probe Working Principle
Переглядів 85 тис.4 роки тому
Working Principles of Vibration Measurement, Axial Thrust and Keyphasor.
Proximity Probe Dynamic Test Demonstration TK3
Переглядів 38 тис.4 роки тому
Testing a proxy probe using Bently Nevada TK3. If you want to build your own test spreadsheet check out the video link at the end of this video.
Proximity Probe Static Test Demonstration, TK3
Переглядів 50 тис.4 роки тому
Incremental Scale Factor Verification. False failure may be indicated over the first 20 mils of the slope. Electrical zeroing the device for the first data point will eliminate this, but is not necessary. Keep in mind; this device is used to measure changes in distance, not the actual distance. This test ensures linear response to object movement. A "How To" video on building a spreadsheet is p...
Multimeter Tutorial
Переглядів 1,4 тис.4 роки тому
An explanation of all multimeter functions in reference to a FLUKE brand meter. Including all secondary functions and alternate (hidden) modes of operation.
Limitorque L120 MOV Limit Switch
Переглядів 3,7 тис.5 років тому
Limitorque L120 MOV Limit Switch
How to Test and Replace a Multimeter Fuse
Переглядів 2,9 тис.5 років тому
How to Test and Replace a Multimeter Fuse

КОМЕНТАРІ

  • @darrelthompson
    @darrelthompson 17 днів тому

    Greate information in this video. Is there a link somewhere that I can download your Resistance Check Spreadsheet?

  • @odiagamer1174
    @odiagamer1174 Місяць тому

    Thank you sir....god bless you....keep posting knowledge.....i really appreciate your hardwork...

  • @hatemmoussa7467
    @hatemmoussa7467 Місяць тому

    How much is this kit?

  • @raulmota1318
    @raulmota1318 Місяць тому

    Hello buddy, can you provide this spreadsheet?

  • @sivasrinivas3716
    @sivasrinivas3716 2 місяці тому

    can i use 8 mm probe to measure radial vibration of a 27 mm nickel alloy shaft?

  • @Time4yes
    @Time4yes 3 місяці тому

    Say, I am using the same valve but I have been given values to start the valve travel at 11 and 13 psi as my full travel. Should I adjust the spring tension first according to these values or should I do on the positioner?

    • @jimdiggins101
      @jimdiggins101 3 місяці тому

      The actuator should have a rated benchset and travel distance. When the control valve assembly was engineered, the actuator specs were selected based on the force required to operate the valve. This test verifies the actuator performs according to the original design. The positioner reduces the error that is a result of mechanical friction.

    • @Time4yes
      @Time4yes 3 місяці тому

      Thanks

  • @sam.castaneda22
    @sam.castaneda22 4 місяці тому

    Need some videos of repairs out in the field

  • @sam.castaneda22
    @sam.castaneda22 4 місяці тому

    Im having issues with a valve currently for leaking by. Hard to find the right kits or someone is not getting the right info for them. Is there a website or something to find the right kits? Based in west texas.

    • @jimdiggins101
      @jimdiggins101 3 місяці тому

      Emerson owns Fisher Valves. From the Emerson website you can find the local business partner as well as drawings.

  • @cavourmartinelli9381
    @cavourmartinelli9381 4 місяці тому

    Simple explanation, but hard to find it. Do you know any supplier I can buy proximeters from? I am located in Brazil.

    • @jimdiggins101
      @jimdiggins101 3 місяці тому

      I don't know. Baker Hughes owns Bently Nevada and they have a global presence. I'm sure there is a local representative. I would check their website.

  • @gregorymaldonado7714
    @gregorymaldonado7714 4 місяці тому

    Hi. Where could I get your excel table ? I would like to get it

    • @jimdiggins101
      @jimdiggins101 4 місяці тому

      Build it in excel. I show all the necessary formulas in one of my videos.

    • @gregorymaldonado7714
      @gregorymaldonado7714 4 місяці тому

      Thank you Sr. I'll do it

  • @dipakbhalodia7155
    @dipakbhalodia7155 4 місяці тому

    Can you provide exell sheet formula

  • @liranhefetz5527
    @liranhefetz5527 5 місяців тому

    PLEASE... Can you provide excel sheet? Thank you very much! +++

  • @sajidkamal8199
    @sajidkamal8199 5 місяців тому

    What is tha input and output radial axial vibration plz answer

    • @jimdiggins101
      @jimdiggins101 4 місяці тому

      I am not sure what you are asking. Can you provide some context?

  • @vinaysane5435
    @vinaysane5435 5 місяців тому

    Like Video.

  • @omagbemigold2321
    @omagbemigold2321 6 місяців тому

    NICE JOB 👍 WELL EXPLAIN

  • @s0nnyburnett
    @s0nnyburnett 6 місяців тому

    Simple to the point explanations, thank you.

  • @karimkrimou1513
    @karimkrimou1513 7 місяців тому

    Thanks sir, it is a very informative vidéo with a clear explanation

  • @abylabylabyl
    @abylabylabyl 7 місяців тому

    where can I get the test sheets?

  • @wapeekung
    @wapeekung 8 місяців тому

    Can you provide excel sheet? Thank you very much

  • @xrafter
    @xrafter 8 місяців тому

    How does the eddy current generate in the metal? Does the varrying magnatic field has something with it?

  • @jeanoliveira8837
    @jeanoliveira8837 8 місяців тому

    WOULD YOU LIKE TO SEND THE TALEBA FOR SENSOR CALIBRATION

  • @kithtube
    @kithtube 9 місяців тому

    Good exlonation jim,thanks.

  • @husseinjavan-bg6sv
    @husseinjavan-bg6sv 9 місяців тому

    Dear sir. I have two probes with different part number, PN: 86691-08065-0435-25 and PN:86691-09246-0435-25. I only know they are 2.5 m length but i am not sure they can be used interchangeably. Is it possible? What are their differences?

    • @jimdiggins101
      @jimdiggins101 9 місяців тому

      I don't have that manual, so I cannot say for certain. From a performance standpoint it should work. Difference will be in the custom features. Such as mounting options, length of armored jacket, etc..

  • @siyabonga6156
    @siyabonga6156 10 місяців тому

    Very good explanation, now I have a better understanding of Proximity probes.

  • @instrumentationbasicknowle2872
    @instrumentationbasicknowle2872 10 місяців тому

    ua-cam.com/video/qd2-NfglGfw/v-deo.htmlsi=pr6vKxgK2ZchdIKA

  • @josepatino7142
    @josepatino7142 10 місяців тому

    Can you provide excel sheet? Thank you very much

  • @arturogonzalez2220
    @arturogonzalez2220 Рік тому

    Jim, where do you get the values for Peak to Peak travel and Measured Value?

    • @jimdiggins101
      @jimdiggins101 11 місяців тому

      I posted videos explaining how to perform the dynamic and static tests.

  • @hondat7435
    @hondat7435 Рік тому

    hello, when i connect the power supply 24VDC positive to the com and negative to the Vt(-24 VDC) it creates an alarm on the power supply and shut down the power supply. Please advice on wiring?

    • @jimdiggins101
      @jimdiggins101 Рік тому

      Power to com and -24. Output signal to out.

  • @crunchyrollo7474
    @crunchyrollo7474 Рік тому

    Thank you very much for the information, although I have a question, at minute 2:24 you put the value of 1 in the voltage column. why 1? What shouldn't be 10mil*200mV= 2V?

    • @jimdiggins101
      @jimdiggins101 Рік тому

      The response rate of 200mV / mil is only valid within the range of linearity. 0-10 mils is outside this range.

  • @nukeworker83
    @nukeworker83 Рік тому

    Best video on youtube!

  • @michaelmorgan9536
    @michaelmorgan9536 Рік тому

    How tight should the jams be tightened. What are the risks of not setting the jam nuts?

    • @jimdiggins101
      @jimdiggins101 Рік тому

      The jams keep the connection block in place In most applications, the feedback arm connects to the block. In some cases, even a slight rotation can create feedback error or loss of position indication.

  • @user-hi7rf3bp8h
    @user-hi7rf3bp8h Рік тому

    What do you supply proximity power with? What kind of lines?

  • @mohammedsaib3844
    @mohammedsaib3844 Рік тому

    Excellent work 👍

  • @shanegovender6780
    @shanegovender6780 Рік тому

    Hi thanks for the video ! We bought a couple of these fisher control valves and we noticed that they don't all have the same bench set values, what's the reason for this ? I also noticed that you did your bench set from 9 to 15 psi, so when will the valve start to move? Is it 9 psi or 3 psi?

    • @jimdiggins101
      @jimdiggins101 Рік тому

      The bench set is engineered to operate the valve based on the process stream and will determine the pressure required to open the valve.

    • @shanegovender6780
      @shanegovender6780 Рік тому

      @@jimdiggins101 thanks so much for the Response! Atleast now I know that I didn't buy the wrong things 😃

  • @JesusEmmanuelGoneCadena-pd2ug

    Dear Jim thanks for video, I only have two questions, at the end we obtained values that were out of tolerance, right? And this was probably because we use other extension cable model, right? In advance thanks for your response! And good job!! 🤘

    • @jimdiggins101
      @jimdiggins101 Рік тому

      Correct. Incorrect length is the most common cause of error

  • @andinstrumentcontrol4159
    @andinstrumentcontrol4159 Рік тому

    Excellent!Can you provide excel sheet? Thank you very much

  • @trinhminhkhoa1969
    @trinhminhkhoa1969 Рік тому

    Thank you for your video. I have a confused question " Can vibration monitoring module supply +24VDC and -24VDC ?"

    • @jimdiggins101
      @jimdiggins101 Рік тому

      Are you referring to the proximitor card on the bently nevada monitoring rack?

    • @trinhminhkhoa1969
      @trinhminhkhoa1969 Рік тому

      @@jimdiggins101 Yes, Sir

  • @uncle_joe
    @uncle_joe Рік тому

    interesting...

  • @playaloc
    @playaloc Рік тому

    I seen some valve bodies have a line on it instead of a flow arrow? Is the line an indication for flow?

    • @jimdiggins101
      @jimdiggins101 Рік тому

      Some have a line on the body that has a downward angle, which represents the flow path through a globe valve. That may be what you are referring to. This alone does not indicate flow however, but for general service, you install with the angled downward part facing up stream so the flow enters below the plug and flows up through the port.

    • @playaloc
      @playaloc Рік тому

      @@jimdiggins101 thanks for the info.

  • @lovesaudiaam3189
    @lovesaudiaam3189 Рік тому

    Excellent

  • @nino4676
    @nino4676 Рік тому

    Thanks

  • @Bwup
    @Bwup Рік тому

    thank you

  • @ShuhardRedd
    @ShuhardRedd Рік тому

    Thank you!

  • @ranjitkar2381
    @ranjitkar2381 Рік тому

    Hi...Mr Jim... thanks for this informative video...kindly could you provide spreadsheet for me...

  • @hovanuc187
    @hovanuc187 Рік тому

    Hi jim diggins. Why is the voltage value according to the datasheet approximately negative -1 to -17vdc. But you take the positive value 1 to 17 vdc

    • @jimdiggins101
      @jimdiggins101 Рік тому

      Voltage is a potential difference and the polarity of the voltage has no bearing on the measurement. Use negative voltage if you like.

  • @agusgimbuk8365
    @agusgimbuk8365 Рік тому

    Excuse me sir. My name is agus. I have some question related with vibration system. 1. Whats the function for minus DC power supply? 2. Whats correlation between DC power supply and AC power supply which generated by probe?

    • @jimdiggins101
      @jimdiggins101 Рік тому

      Answer 1: The polarity doesn't matter unless you are a transistor, which in this case is why the polarity is reversed. For the purpose of understanding how it works, it makes little difference.

    • @jimdiggins101
      @jimdiggins101 Рік тому

      Answer2: Think of the AC as DC with a wave. Normal AC changes polarity, this doesn't. You just have to switch a meter to AC to measure the dynamics of the sinewave that is created. It's AC with a voltage bias.

  • @devivara1162
    @devivara1162 Рік тому

    How belt conveyor receive TPH from DCS??

  • @devivara1162
    @devivara1162 Рік тому

    Sir what is solnide valve???

    • @jimdiggins101
      @jimdiggins101 Рік тому

      A solenoid valve-discrete valve activated by a magnetic coil. In a control valve it is commonly used to interrupt air supply and force to a fail state.

  • @devivara1162
    @devivara1162 Рік тому

    Sir why gearbox and coupling needed for alternator in powerplant???

  • @kantipudijanakiramayyachow2844

    Thanks