Safwan Batchi
Safwan Batchi
  • 3
  • 15 921
DIY HEAT PUMP WATER HEATING RESEDENTIAL HEATING - 5 Ton
DIY HEAT PUMP WATER HEATING RESEDENTIAL HEATING - 5 Ton
Переглядів: 9 695

Відео

DIY HEAT PUMP WATER HEATING RESEDENTIAL HEATING
Переглядів 2,8 тис.4 роки тому
Modified R-22 5 Ton old and used outdoor unit Air to Air) to heat water through BPHE (Brazed Plate Heat Exchanger) inside the developed indoor unit. The heated water is then cycling the radiators pumping heat inside house replacing deisel boiler function. An air source controller board is added to sense temperatures ( Discharge, Suction, Liquid, Gas, and inlet and outlet water) , input signals ...

КОМЕНТАРІ

  • @R290s_biggest_fan
    @R290s_biggest_fan 7 місяців тому

    Where did you get that heat exchanger?

  • @Bmadd67
    @Bmadd67 11 місяців тому

    What was the heat exchanger that you used? How many btu’s?

  •  Рік тому

    Do you know what refrigerant is used?

  • @aleksandarmilosevic9654
    @aleksandarmilosevic9654 Рік тому

    What control are you using to control outside unit?

  • @johannienel1
    @johannienel1 2 роки тому

    This is awesome. Do you have an update on your system please?

  • @呵呵呵呵-l6i
    @呵呵呵呵-l6i 2 роки тому

    Unbelievable, some one just changed the compressor in 2019 and scraped the whole unite.(from the serial number, the compressor is made in 2019)

    • @safwanbatchi1380
      @safwanbatchi1380 2 роки тому

      didn't notice regarding the serial number but I assumed the compressor swaped recently as it looks new for an old 18 years old outdoor unit.

    • @USA-GreedyMenOfNoIntegrity
      @USA-GreedyMenOfNoIntegrity Рік тому

      Here’s how it goes. I go out find a compressor locked up, no refrigerant in the system. I can either put in a new heat pump and pretend there’s nothing wrong with the air handler or I can do a leak search and find the leak in the air handler, then sell them a whole new system inside and out. Whoever replaced the compressor without determining why it failed was a jackleg and didn’t do his job properly.

  • @CATA20034
    @CATA20034 2 роки тому

    your heat exchanger is a trap for compressor oil. Swap the lines...

    • @johnfloros
      @johnfloros 2 роки тому

      why is that?

    • @safwanbatchi1380
      @safwanbatchi1380 2 роки тому

      the lines order to obtain the higher heat transfer efficiency; heated water outlet on same side of discharge refrigerant line on heat exchanger. Total circuit length is considered short to guarantee oil circulation. working since two years with no indication of oil circuit problem.

  • @valentin1602
    @valentin1602 3 роки тому

    Heat exchanger?

  • @olimpiusorin9191
    @olimpiusorin9191 3 роки тому

    What controller unit and controller board did you use?

  • @leosee7588
    @leosee7588 3 роки тому

    Nice job! Welding like a pro! I wonder you KW/hrs you pay for you electrical consumption? Because hire in Canada we payings .95 cents/ kwhr and it’s not worthy to have a heat pump for domestic water!

    • @solexxx8588
      @solexxx8588 2 роки тому

      Much better than an immersion heater. COP is 3+ compared to 1 for immersion heating.

  • @TheHoppala007
    @TheHoppala007 3 роки тому

    well I have not much idea about the aircon but a question, was "Modified R-22 5 Ton old and used outdoor unit Air to Air" a AC in original but you modify it to run as a heat Pump ? would be nice to see how to modify :-) . I think I can also find such things cheap from scrap yard. But I am still not confident to start all without previous exprience with Aircons :-D . All I know is I am willing to do and I can find all those component cheap in scrap yard.

    • @safwanbatchi1380
      @safwanbatchi1380 2 роки тому

      Actually yes, it was ducted split air to air heat pump modified to air to water heat pump.

  • @panagiotism0189
    @panagiotism0189 3 роки тому

    Where can i find the controller board?

    • @safwanbatchi1380
      @safwanbatchi1380 3 роки тому

      a.aliexpress.com/_mLyi9a7

    • @555_shoe
      @555_shoe 2 роки тому

      @@safwanbatchi1380 would you be so kind to tell us the description of the controller board, because the link has expired!

  • @KlimatyzacjaKatowicepl
    @KlimatyzacjaKatowicepl 3 роки тому

    Dobre

  • @khalidabufarha1594
    @khalidabufarha1594 3 роки тому

    عفية عليك.. ابداع و تطوير واضح

  • @ESSronson
    @ESSronson 3 роки тому

    Great work

  • @khalidabufarha1594
    @khalidabufarha1594 4 роки тому

    جرئ و مثير