GAUTAM  KUMAR - PARAMEDIC
GAUTAM  KUMAR - PARAMEDIC
  • 19
  • 172 515
How to do #prime #calibrate &#error_remove in #Bio-Rad #d10 #hplc#hba1c @analyzer
Hii Friends
welcome to my UA-cam channel.
Today I am going to tell you how to solve the proper errors in Bio Rad D10 model machine and also how we will prime, why it is done and what is the process of calibration
Any Enquiry about video please send message:
gautambudha96@gmail.com
if any query related BIO-RAD please visit:
www.bio-rad.com/
D-10 Hemoglobin Testing System: Low and Medium Volume Glycohemoglobin Testing
The D-10 is a fully-automated system that is an aid in diabetes diagnosis and monitoring, as well as offers β-thalassemia testing on a single platform. Programs for rapid HbA1c and HbA2/F/A1c are only a touchscreen away and can easily be integrated into your current laboratory workflow.
This compact platform allows for maximum performance in minimum space. The D-10 high-performance liquid chromatography system sets a new standard of performance for comprehensive hemoglobin testing
Superior Performance with Simplified Operation
Primary tube sampling-eliminates manual sample preparation in
Bar code reader automatically tracks patient samples
Chromatogram export helps clinicians see potential interferences
On-board QC monitoring ensures performance
D-10 Hemoglobin A1c Program
Screen for prediabetes, diagnose, and monitor patients living with diabetes
A1c results in three minutes
Calibrate once per cartridge
NGSP certified, IFCC anchored and DCCT traceable
D-10 Dual Kit
Fast switching between short and extended method
Reliable β-thalassemia testing with improved HbA2 resolution from HbS
Detection of common hemoglobin variants
NGSP certified and anchored to the IFCC reference method
D-10 Hemoglobin Testing System delivers superior performance in a compact package.
Переглядів: 1 841

Відео

How to resolve Vacuum pressure abnormal/high error in #erba #H560,#cell counter
Переглядів 1,1 тис.11 місяців тому
we will discuss how to resolve Vacuum pressure abnormal/high in @erba #H560 Cell counter
How to remove the Communication error of #erba #em360_#Biochemistry_#analyze#fusechange
Переглядів 12911 місяців тому
#errordetection how to resolve the issue of #erba #EM360 #error message #analyser not responding at COM1 first you see all the fuses....
Display the process of Add #calibrations check#regents #inventory & consumption #add test profile,
Переглядів 76Рік тому
Hello this is Gautam k.Ravi today.I will display it in front of you and view the process of How to add a calibrator,How to check inventory or monthly reagents consumption and last viewing about create test profile in #beckman,#coulter #au480 thanks for giving you the precious time for my videos.
How To Add Calibrator And Do Calibration#laboratory#calibrations #em360 #gautam
Переглядів 3812 роки тому
we're going to discuss about how to add Calibrator, and calibration done.. 🙏 video captured & Editing by Jitu...
we'll discuss about ERBA EM 360, its parts & how to do start. #erbaa#laboratory#startup#parts
Переглядів 1672 роки тому
Hi guys this Gautam Medical lab info Today we'll discuss about Erba EM 360 fully automated biochemistry analyzer.. how to work and we also discuss about it's parts. 🙏🙏
Overview lecture of newly opened laboratory#laboratory#erbaa#analysernews
Переглядів 1832 роки тому
Hey Guys, Today I am going to discuss about a newly opened laboratory. Equipments Mentioned in this video are: 1.Campact cooling centrifuge 2 Biochemistry full Autoanalyser 3 Urinalysis 4 Hematology. Thank you🙏🙏🙏🙏
_#laboratoryequipment how to test perform in automated immunoassay mini VIDAS machine_#pathology
Переглядів 26 тис.3 роки тому
_#laboratoryequipment how to test perform in automated immunoassay mini VIDAS machine_#pathology
How to run system check solution & how to make dilution of system check.(Beckman coulter access 2)
Переглядів 7 тис.3 роки тому
Presented by_Gautam Video recorded by _Md Ehtesham Video editor by _ Gautam Beckman coulter access 2. How to run system check solution & dilution process.
How to do calibrater add in Beckman Coulter Au480.
Переглядів 22 тис.3 роки тому
Today we're discussing about how to do calibrater add in Beckman Coulter AU480.
How to resolve cuvette errors in Au480 beckman coulter.
Переглядів 11 тис.4 роки тому
How to resolve cuvette errors in Au480 beckman coulter.
Today we are talking to about how to doing calibration backman coulter access 2.
Переглядів 12 тис.4 роки тому
Today we are talking to about how to doing calibration backman coulter access 2.
Manual urine protein test
Переглядів 3294 роки тому
Manual urine protein test with heat and acitic acid test.
Maintenace of beckman coulter acces-2
Переглядів 22 тис.4 роки тому
maintenance of beckman coulter acces-2.
Daily Maintenance of Beckman Coulter AU480 Biochemistry Analyzer
Переглядів 61 тис.4 роки тому
Daily Maintenance of Beckman Coulter AU480 Biochemistry Analyzer
Types of Vials and their uses ll Gautam Kumar Ravi ll #Lab_Information
Переглядів 3514 роки тому
Types of Vials and their uses ll Gautam Kumar Ravi ll #Lab_Information
Benefits of Blood Donation by Gautam l danate blood -save life!
Переглядів 2364 роки тому
Benefits of Blood Donation by Gautam l danate blood -save life!
How to do Ultra PAP Smear Staining l Gautam Kumar
Переглядів 6 тис.4 роки тому
How to do Ultra PAP Smear Staining l Gautam Kumar
How to Use Sysmex 3 Part CBC Machine ll Gautam Kumar
Переглядів 1,9 тис.4 роки тому
How to Use Sysmex 3 Part CBC Machine ll Gautam Kumar