- 88
- 45 927
Electrical Supervisor
Приєднався 24 жов 2023
The Channel Electrical Supervisor is the team of Electrical Engineer, Electrician, Technician & Electrical Fabricator
Channel provide the update of industrial electrical work of the following and many more
1) Electrical Panel dressing and termination
2) Cable selection
3) Cable gland selection
3) Hole Saw Cutting in entry plate of electrical panel
4) Hole saw cutter selection
5) Defferent types of Flame Proof/ Weather Proof industrial light fitting and termination
6) Motor Connection
7) Motor Starter
8) Sharing knowledge of Different types of Circuit breaker MCB, LCB, RCCB, MCCB & VCB
9)Centrifuge control panel connection
10) Reactor control panel connection
11) RTD connection
12) Temperature/ Humidity Senser installation and connection
13) Room cleaner
14) Knowledge of cable tray
15) Camera installation and connection
16) Data/Telephone panel connection
17) LCB testing
18) Electrical Panel thermography
19) Meggering
And Many more....
Channel provide the update of industrial electrical work of the following and many more
1) Electrical Panel dressing and termination
2) Cable selection
3) Cable gland selection
3) Hole Saw Cutting in entry plate of electrical panel
4) Hole saw cutter selection
5) Defferent types of Flame Proof/ Weather Proof industrial light fitting and termination
6) Motor Connection
7) Motor Starter
8) Sharing knowledge of Different types of Circuit breaker MCB, LCB, RCCB, MCCB & VCB
9)Centrifuge control panel connection
10) Reactor control panel connection
11) RTD connection
12) Temperature/ Humidity Senser installation and connection
13) Room cleaner
14) Knowledge of cable tray
15) Camera installation and connection
16) Data/Telephone panel connection
17) LCB testing
18) Electrical Panel thermography
19) Meggering
And Many more....
Air Compressor Fully Automatic Star Delta Starter Connection | Industrial Electrical Work
Air Compressor Fully Automatic Star Delta Starter Connection | Industrial Electrical Work
Переглядів: 928
Відео
Electrical Changeover Cable Gland Termination Industrial Electrical Work
Переглядів 1,6 тис.4 місяці тому
Electrical Changeover Cable Gland Termination Industrial Electrical Work
FRP Cable Tray 90 Degree Bend | Electrical Cable Tray Fabrication Work
Переглядів 1,3 тис.4 місяці тому
FRP Cable Tray 90 Degree Bend | Electrical Cable Tray Fabrication Work
How to Bend FRP Cable Tray 90 Degree ? Electrical Cable Tray Installation | Industrial Work
Переглядів 4355 місяців тому
How to Bend FRP Cable Tray 90 Degree ? Electrical Cable Tray Installation | Industrial Work
Centrifuge Control Panel Wiring and Connection | Industrial Electrical Work
Переглядів 566 місяців тому
Centrifuge Control Panel Wiring and Connection | Industrial Electrical Work
Vaccum Circuit Breaker | VCB Short Video | Electrical Industrial Work #electrical
Переглядів 756 місяців тому
Vaccum Circuit Breaker | VCB Short Video | Electrical Industrial Work #electrical
300 Sqmm Electrical Panel Glanding And Termination | Industrial Electrician Work
Переглядів 5 тис.7 місяців тому
300 Sqmm Electrical Panel Glanding And Termination | Industrial Electrician Work
3 Phase Motor Starter Connection | Industrial Electrical Work
Переглядів 1717 місяців тому
3 Phase Motor Starter Connection | Industrial Electrical Work
SPN DB Cable Dressing And Connection | Power Distribution Board
Переглядів 937 місяців тому
SPN DB Cable Dressing And Connection | Power Distribution Board
Industrial Motor Control Panel Tutorial | Electrician | Electrical Supervisor
Переглядів 8 тис.7 місяців тому
Industrial Motor Control Panel Tutorial | Electrician | Electrical Supervisor
Cable Gland Termination | Industrial Electrician Work | Electrical Panel Connection
Переглядів 2588 місяців тому
Cable Gland Termination | Industrial Electrician Work | Electrical Panel Connection
Motor Controller Panel Wiring Connection | Industrial Electrical Work
Переглядів 8198 місяців тому
Motor Controller Panel Wiring Connection | Industrial Electrical Work
500 KVA DG Cable Termination | Industrial Electrician Work | Electrical Room
Переглядів 3958 місяців тому
500 KVA DG Cable Termination | Industrial Electrician Work | Electrical Room
Induction Motor Connection | Cable Gland Termination | Star Connection | Industrial Electrical Work
Переглядів 1978 місяців тому
Induction Motor Connection | Cable Gland Termination | Star Connection | Industrial Electrical Work
How to Install Flame Proof Monochromatic Clean Room Light on Ceiling of Fire Proof Wall Panel
Переглядів 1298 місяців тому
How to Install Flame Proof Monochromatic Clean Room Light on Ceiling of Fire Proof Wall Panel
BJI 218 LED PC wiring | Bajaj Industrial LED Connection | BJI 118 LED PC
Переглядів 97Рік тому
BJI 218 LED PC wiring | Bajaj Industrial LED Connection | BJI 118 LED PC
Hello sir number nhi diya apne
Sir rispons nhi diya sir please help me sir
Love you sir
Contact me
Nice 👍
Job location sir
Ambernath, Maharashtra, India
@@Electrical_Supervisor ok sir a jaye ge ap apna number send kar dijiye sir
Sir job chahiye
Electrical Engineer
Job location
Ambernath, Maharashtra
Sir job lgwa do diploma in Electrical Engineering
Kitni salary expect kar rahe ho ?
Aur work experience kitna hai ?
Diploma in Electrical Engineering
Cable 400 sq mm 3.5 cor
We use upto 300 sqmm 3.5C
400 sq mm cable 3.5 cor full Amps ???
How about electrical engineer
Electrical supervisor work under electrical engineer. And electricians work under electrical supervisor
Gland size used for 300 mm2 ?
63 mm
75
Es penal ka kiya naam hai
Thanks. Sar. ji
kidarka video a
Ultratech
Alag Alagse connection dekhateto bahut achxa hoga😅😅
Ok
Hellooo sir how can we learn it properly step by step
For theory, look at the Contactor diagram and then go to the controlling panel and do the practical with an experienced person.
Good luck
иι¢є
Right ✅️ ↔️ 👉 🔛 ➡️
How calculate that cable size
Method -1 We talk about 3 phase, heavy load, and Aluminium cable. According to Ampere load = near by available cable size Example-1, 60A load, here available cable near below 60 are 50 sqmm and 35 sqmm If the cable length below 100 mtrs we use 35 sqmm If the cable length above 100 mtrs we use 50 sqmm cable. Example-2, 300A load, here available cable near 300 are 300 sqmm and 240 sqmm If the cable length below 100 mtrs we use 240 sqmm cable and if the cable length above 100 mtrs we use 300 sqmm cable. You may use 2 run of 150 sqmm cable against 300 sqmm single cable. Similarly for 1000A load We use 3 run of 300 sqmm cable For 1600A load we use 5 run of 300 sqmm cable. For Copper cable multiply the Ampere by 1.2 and use above method. Method -2 For below 30A load and copper cable ...we just use Below 1KW load - 1.5 sqmm 2-3 KW load - 2.5 sqmm 3-5 KW load - 4 sqmm 5-9 KW load - 6 sqmm 9-12 KW load - 10 sqmm 12-16 KW load - 16 sqmm 16-25 KW load - 25 sqmm For aluminium cable Divide the load(KW) by 1.2 and use above method ☝️
If you want to use formula then I recommend use formula Power in KW(Load) = Volt x Current x power factor Example 3 phase load given 8 KW So, 8 KW = 8000W = 415(volt) x I(current) x 0.8 (pf) You Get I (current ) = 8000/(415*0.8) = 24A Now for safety I = 24 x 1.5 or 2 = 36 to 48 A Now search on google current capacity of Cu cable If you found 6 sqmm cable capacity = 33 A 10 sqmm cable capacity= 45 A And you calculate your current capacity= 36A to 48A According to your calculation 10 sqmm cable better for safety but you may use 6 sqmm cable too.
Apna number btao Bhai....
Number kis liye chahiye bhai
Full video link ua-cam.com/video/v7B0rTeMvx4/v-deo.html
Schematic diagram per bhi video banao
InshAllah jald hi banaunga
Pagol naki?? Ki video te ki music lagaise
You're right but this is vocal sound... next time i take care of it....thank you ❤
Super
Thanks ❤️
DG panel and Cable termination video link ua-cam.com/video/NHgKTonfVXw/v-deo.htmlsi=yd-L-BsLrQz7u83g
Great work 🤲🏽
Thank you 🙌
Saprort कर रहे aap ko mai bhi ek Electrican hun 95k subscriber mai mere subscribe kar diya