Chromatography Basics Philippines
Chromatography Basics Philippines
  • 8
  • 17 818
How to Add License in OpenLab ChemStation Software | OpenLab | Agilent
This is the steo by step procedure on how to add the license file of agilent openLab Chemstation Software.
Comment down below if you have any question.
and please don't forget to Like and Subscribe.
#agilentgaschromatography #gaschromatography #analyticalchemistry
Переглядів: 1 426

Відео

How to Change the GOLD PLATED SEAL | GAS CHROMATOGRAPHY
Переглядів 3973 роки тому
This video will guide you how to change the gold plated seal in your split and splitless inlet #GoldPLATEDSEAL #AGILENT #GASCHROMATOGRAPHY #BASICTIPS
MANUAL INJECTION IN GAS CHROMATOGRAPHY | NO ALS | Chromatography Basics Philippines | Tagalog
Переглядів 1,9 тис.4 роки тому
This Video is about manual injection analysis in Gas Chromatography. sometimes our GC don't have autosampler so I made quick video on how to set-up and run using Manual Injection #ManualInjection #GasChromatography #GC
SST EVALUATION + Camag HPTLC
Переглядів 4934 роки тому
System Suitability Test in Camag VisionCats #Camag #HPTLC #SST
How to change change MSD DATA ANALYSIS from Enhanced to EnviQuant (Agilent MSD DATA ANALYSIS)
Переглядів 4224 роки тому
this video shows how to change your configuration of Agilent MSD Data Analysis from Enhanced to Enviquant without reconfiguring in Agilent configuration. This changing of configuration normally used to EnviQuant if you want to print or export you data or results to Excel file or saving as CSV file for LIMS. #Philippines
how to change, install and align the syringe for GC ALS Philippines
Переглядів 11 тис.5 років тому
This video tutorial show's how to change, install and align the agilent als.
how to change inlet septa - philippines
Переглядів 1 тис.5 років тому
This video show how to change septum in the inlet. Normally we change the septa 70-100 injection or if the septa is already worn out. If we didn't change the septa we could experience leak or inlet shutdown
how to install inlet liner - philippines
Переглядів 6975 років тому
This video shows how go install inlet lined for your gas chrom

КОМЕНТАРІ

  • @noblechris07
    @noblechris07 11 місяців тому

    you tighted the septa too much

  • @swapnilzanke6101
    @swapnilzanke6101 11 місяців тому

    Pls upload more videos

  • @salve1185
    @salve1185 Рік тому

    please make more tutorial vids on chemlab gc software navigation like how to data processing, etc

  • @user-kc3jp9vz1f
    @user-kc3jp9vz1f 2 роки тому

    Thank you!

  • @jayzeeabad1258
    @jayzeeabad1258 2 роки тому

    Sir pano mag install ng openlab kapag may server and instrument controller?

  • @shamialgawzi8277
    @shamialgawzi8277 2 роки тому

    My advise to modify the channel name to Chromatography Basic (global), very good explanation.

  • @edanonuevo5128
    @edanonuevo5128 3 роки тому

    Sir tanong kulang po, napapalitan po ba yang parang bulak sa loob ng inlet liner?

    • @chrombasicsphilippines
      @chrombasicsphilippines 3 роки тому

      Yes pwde mo po sya palitan yung glasswool. Need mo nga lang po linisin ng maayos yan. Ang mahirap po na part is meron kasi syang sukat kung gaano karamo ung wool. Not sure lang sa exact na amount. :)

    • @edanonuevo5128
      @edanonuevo5128 3 роки тому

      @@chrombasicsphilippines ginawa ko kc yan sir, tinangal ko yung nasa loob ng inlet liner tapos tinimbang ko tapos pinalitan ko ng glass wool yung nga lang Nag NG ang machine pangit yung baseline nya..

    • @chrombasicsphilippines
      @chrombasicsphilippines 3 роки тому

      Yup possoble po sya since ung pagkaka packed po ni agilent is precise. Nalinis mo po ng maayos ung liner (glass)? Baka may residue pa ng ginamit mo solvent kaya di po ok baseline. Try mo po icondition muna ang system. Until mareach mo ung stable baseline (after 2-3hrs at 200 degC column and inlet at 250degC).

    • @edanonuevo5128
      @edanonuevo5128 3 роки тому

      @@chrombasicsphilippines opo sir, gumanda lang yung baseline after 3rd trial saka sya nag ok ng mapalitan, problema nga lang sir after 2days balik ulit sa dati.. napansin ko sir yung nilagay ko na glass wool sa inlet ay nakaangat na ng tiningnan ko.. maganda namn pagkakalagay ..

    • @chrombasicsphilippines
      @chrombasicsphilippines 3 роки тому

      Kapag kasi sir nag iinject yung syringe tumatama yan sa sa glasswool. Kaya possible reason ng pagangat. (Tumatama pag refill lang po. Yapos yung wool sa liner mo ay nasa gitna pag straight liner for split or ung taper liner na may wool) Sa original liner wool kasi hindi aangat pag nagiinject ang nangyayari po sakanya napush pababa po. Ano po ba Part Number ng liner na gamit mo? Ano pala ang sample or sample matrix mo sir? Mabilis masira glasswool sa liner mo? By the way sir meron iba’t ibang liner na pwde mo magamit depende sa analysis mo.

  • @swapnilzanke6101
    @swapnilzanke6101 3 роки тому

    Full tutorial can available

  • @iskoystory2291
    @iskoystory2291 3 роки тому

    Sir, question. May orientation po ba yung liner pag nilagay na sa inlet? Naobserve ko kasi may bump/button sya sa bottom part.

  • @user-rs6xt5zd2f
    @user-rs6xt5zd2f 3 роки тому

    666